The 24cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instr
The 24cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1520G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 24cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instru
The 24cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1520G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 10cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instr
The 10cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1520G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 10cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instru
The 10cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1520G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The Preamplifier Box is a part of the DuoFLEX® Coil Suite. The MR Instruments F
The Preamplifier Box is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1520G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 24cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instr
The 24cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 24cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instru
The 24cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 10cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instr
The 10cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 10cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instru
The 10cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The Preamplifier Box is a part of the DuoFLEX® Coil Suite. The MR Instruments F
The Preamplifier Box is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 24cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instr
The 24cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1500S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 24cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instru
The 24cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1500S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 10cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instr
The 10cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1500S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 10cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instru
The 10cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1500S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The Preamplifier Box is a part of the DuoFLEX® Coil Suite. The MR Instruments F
The Preamplifier Box is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 1500S-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 24cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instr
The 24cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 24cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instru
The 24cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 10cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instr
The 10cm Right Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The 10cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instru
The 10cm Left Coil Assembly is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The Preamplifier Box is a part of the DuoFLEX® Coil Suite. The MR Instruments F
The Preamplifier Box is a part of the DuoFLEX® Coil Suite. The MR Instruments FC 3000G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The MR Instruments FC 1500G-8R DuoFLEX® Coil Suite includes two different sets o
The MR Instruments FC 1500G-8R DuoFLEX® Coil Suite includes two different sets of coil paddles and a single, shared preamplifier box with a system connector. The first coil set consists of two 24cm foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. The second coil set consists of two 10cm square foam paddles containing four loops/channels per paddle for a total of eight channels for the two paddles. All of these paddles connect to the same preamplifier box containing eight preamplifiers; only one pair can be connected at a time. The coil design for all of the paddles has the same, simple antennae design and the same system connectivity configuration. The coils can be used in several configurations, including any single coil and any two coils, providing 4 or 8 channels for imaging.
The MC 3003G-32R is a multi-channel receive only RF head coil. It has 32 RF ele
The MC 3003G-32R is a multi-channel receive only RF head coil. It has 32 RF elements that are tuned to 1H at 3T (127.8 MHz). Each element has active and passive blocking networks and integrated preamplifiers. The housing is constructed out of a rigid plastic with an opening for patient viewing and comfort. A head support/base is included.
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings.The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy.During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniformcoverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receivesmagnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magneticfield applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRIscanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings.The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy.During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
The NeoCoil 1.5T 16ch Breast Coil is a phased array coil for imaging structures
The NeoCoil 1.5T 16ch Breast Coil is a phased array coil for imaging structures of the breast, axilla and chest wall. The 1.5T 16ch Breast Coil is a three part receive-only coil designed to provide high resolution imaging. The 1.5T 16ch Breast Coil includes a coil support structure, patient support structure, biopsy components and comfort pads.
The NeoCoil 3.0T 16ch Breast Coil is a phased array coil for imaging structures
The NeoCoil 3.0T 16ch Breast Coil is a phased array coil for imaging structures of the breast, axilla and chest wall. The 3.0T 16ch Breast Coil is a three part receive-only coil designed to provide high resolution imaging. The.3.0T 16ch Breast Coil includes a coil support structure, patient support structure, biopsy components and comfort pads.
These accessory immobilization devices are intended for use in conjunction with
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coi
These accessory immobilization devices are intended for use in conjunction with
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coi