Other products from "OVESCO ENDOSCOPY AG"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 04260206311485 17/18 400.32.04 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • tapered design allowing precise dilation in millimetre increments • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
2 04260206311461 15/16 400.32.03 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • tapered design allowing precise dilation in millimetre increments • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
3 04260206311447 13/14 400.32.02 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • tapered design allowing precise dilation in millimetre increments • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
4 04260206311423 11/12 400.32.01 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • tapered design allowing precise dilation in millimetre increments • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
5 04260206311409 9/10 400.31.03 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • tapered design allowing precise dilation in millimetre increments • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
6 04260206311386 7/8 400.31.02 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • tapered design allowing precise dilation in millimetre increments • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
7 04260206310808 7 400.31.01 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
8 04260206311249 mini/6 t 100.02 The mini OTSC System extends the OTSC System by a smaller size • it can be use The mini OTSC System extends the OTSC System by a smaller size • it can be used for the same indications as the OTSC System means acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • can especially be used in small lumen or where access is an issue • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 mini OTSC System Set
9 04260206311232 mini/6 a 100.01 The mini OTSC System extends the OTSC System by a smaller size • it can be use The mini OTSC System extends the OTSC System by a smaller size • it can be used for the same indications as the OTSC System means acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • can especially be used in small lumen or where access is an issue • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 mini OTSC System Set
10 04260206311119 10/3 t 100.02 The mini OTSC System extends the OTSC System by a smaller size • it can be use The mini OTSC System extends the OTSC System by a smaller size • it can be used for the same indications as the OTSC System means acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • can especially be used in small lumen or where access is an issue • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 mini OTSC System Set
11 04260206311102 10/3 a 100.01 The mini OTSC System extends the OTSC System by a smaller size • it can be use The mini OTSC System extends the OTSC System by a smaller size • it can be used for the same indications as the OTSC System means acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • can especially be used in small lumen or where access is an issue • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 mini OTSC System Set
12 04260206310976 185 cm 200.57.04 The AWC is an additional working channel for flexible endoscopes • external ch The AWC is an additional working channel for flexible endoscopes • external channel for insertion of instruments or flushing and suction • it consists of: distal attachment (cap) shaft adaptor for fixation at the endoscope handle sleeve valve and Luer Lock connection tapes for fixation • for colonoscopes with insertion length of 160 - 170 cm FZX Guide, Surgical, Instrument 1 AWC
13 04260206310952 122 cm 200.57.01 The AWC is an additional working channel for flexible endoscopes • external ch The AWC is an additional working channel for flexible endoscopes • external channel for insertion of instruments or flushing and suction • it consists of: distal attachment (cap) shaft adaptor for fixation at the endoscope handle sleeve valve and Luer Lock connection tapes for fixation • for gastroscopes with insertion length of 103 - 110 cm FZX Guide, Surgical, Instrument 1 AWC
14 04260206310938 12 400.02.01s The remOVE DC Cutter Set 12 consists of the following products: remOVE DC Cutter The remOVE DC Cutter Set 12 consists of the following products: remOVE DC Cutter is a bipolar endoscopic direct current (DC) instrument for fragmentation of OTSC and FTRD clips in the digestive tract • consists of an insulated conducting wire with an exposed tip • intended to conduct the direct current (DC) supplied by the remOVE DC Impulse to a previously implanted clip • separation of the clip through resistive heating • remOVE DC Cutter is designed to be used only with the remOVE DC Impulse and flexible endoscopes remOVE SecureCap 12 is an elastic and transparent retrieval cap for safe extraction of the clip fragments remOVE Grasper is a grasping forceps for retrieval of clip fragments into the remOVE SecureCap • for removal of these fragments out of the GI tract QAG Endoscopic Electrosurgical Clip Cutting System 2 remOVE DC Cutter Set
15 04260206310921 14 400.02.02s The remOVE DC Cutter Set 14 is part of the remOVE System and consists of the fol The remOVE DC Cutter Set 14 is part of the remOVE System and consists of the following products: remOVE DC Cutter is a bipolar endoscopic direct current (DC) instrument for fragmentation of OTSC and FTRD clips in the digestive tract • consists of an insulated conducting wire with an exposed tip • intended to conduct the direct current (DC) supplied by the remOVE DC Impulse to a previously implanted clip • separation of the clip through resistive heating • remOVE DC Cutter is designed to be used only with the remOVE DC Impulse and flexible endoscopes remOVE SecureCap 14 is an elastic and transparent retrieval cap for safe extraction of the clip fragments remOVE Grasper is a grasping forceps for retrieval of clip fragments into the remOVE SecureCap • for removal of these fragments out of the GI tract QAG Endoscopic Electrosurgical Clip Cutting System 2 remOVE DC Cutter Set
16 04260206310389 1.5 mm 200.53.01 The AqaNife is a monopolar electrosurgical instrument for dissection using flexi The AqaNife is a monopolar electrosurgical instrument for dissection using flexible endoscopes • precise marking of tissue • stable position of the needle • ceramic socket as stopper and protector • opening in the ceramic socket for flushing and re-injection • for thin tissue (needle length of 1.5 mm) GEI Electrosurgical, Cutting & Coagulation & Accessories 2 ESD AqaNife
17 04260206310907 16 400.32.03 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
18 04260206310884 14 400.32.02 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
19 04260206310860 12 400.32.01 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
20 04260206310846 10 400.31.03 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
21 04260206310822 8 400.31.02 The BougieCap is for dilation of strictures in the upper gastrointestinal tract The BougieCap is for dilation of strictures in the upper gastrointestinal tract • the transparent cap allows direct visual control during the dilation • the tension on the tissue is visible while passing the stricture, thereby avoiding overstretching • reduced procedure time due to less intrument change • evaluation can be done directly after the dilation thanks to the attached transparent cap • two lateral holes for air insufflation and suction • one centered hole for the insertion of a guide wire KNQ Dilator, Esophageal 2 BougieCap
22 04260206310334 12/6 t - 220 100.31 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
23 04260206310655 FTRD 13 200.72 The gastroduodenal FTRD Set is a novel tool for diagnostic and therapeutic full- The gastroduodenal FTRD Set is a novel tool for diagnostic and therapeutic full-thickness (or deep wall resection, especially in the stomach) resection via flexible endoscopy in the stomach and duodenum • technology is based on the well-established OTSC System • enabling the endoscopist to resect all layers of suitable lesions including the serosa • the transection of the tissue happens only after the tissue has been closed completely • bowel lumen and abdominal cavity won't get into contact • It consists of the following five instruments, all single-use:• gastroduodenal FTRD (application cap with preloaded clip (special design for use in duodenum), integrated HF snare, endoscope sleeve, hand wheel and thread retriever • for colonoscopes)• FTRD Marking Probe (HF coagulation probe marking of the target lesion in preparation of FTRD use for detection and complete resection of the right tissue)• FTRD Grasper (specially designed grasping forceps proper grip on the target tissue precise retrieval of the sample into the application cap of the FTRD)• Insertion balloon (used to facilitate the insertion of the gastroduodenal FTRD through the mouth in the upper GI tract consists of a balloon, radiopaque markers, a catheter, a three-way handle and a yellow marker)• Guide wire (provided as insertion aid for the gastroduodenal FTRD to facilitate the insertion of the device into the upper GI-tract used in conjunction with an insertion balloon) PKL,FDI,KNS Hemostatic Metal Clip For The Gi Tract,Snare, Flexible,Unit, Electrosurgical, En Hemostatic Metal Clip For The Gi Tract,Snare, Flexible,Unit, Electrosurgical, Endoscopic (With Or Without Accessories) 2 gastroduodenal FTRD Set
24 04260206310631 Proctology 200.62 The Fistula Brush can be used for probing of the fistula tract and for debrideme The Fistula Brush can be used for probing of the fistula tract and for debridement before using the OTSC Proctology • it is used to clean the fistula tract and remove granulation tissue • supports obliteration of fistula tract MDM Instrument, Manual, Surgical, General Use Fistula Brush
25 04260206310419 3.0 mm 200.53.04 The AqaNife is a monopolar electrosurgical instrument for dissection using flexi The AqaNife is a monopolar electrosurgical instrument for dissection using flexible endoscopes • precise marking of tissue • stable position of the needle • ceramic socket as stopper and protector • opening in the ceramic socket for flushing and re-injection • for thick tissue (needle length of 3.0 mm) GEI Electrosurgical, Cutting & Coagulation & Accessories 2 ESD AqaNife
26 04260206310396 2.0 mm 200.53.02 The AqaNife is a monopolar electrosurgical instrument for dissection using flexi The AqaNife is a monopolar electrosurgical instrument for dissection using flexible endoscopes • precise marking of tissue • stable position of the needle • ceramic socket as stopper and protector • opening in the ceramic socket for flushing and re-injection • for thin tissue (needle length of 2.0 mm) GEI Electrosurgical, Cutting & Coagulation & Accessories 2 ESD AqaNife
27 04260206310327 12/6 a - 220 100.30 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
28 04260206310310 12/3 t - 220 100.29 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
29 04260206310303 12/3 a - 220 100.28 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
30 04260206310297 220 cm 200.11 The OTSC Anchor 220tt is one of the OTSC application aids • can be used for tr The OTSC Anchor 220tt is one of the OTSC application aids • can be used for treating a lesion before release of the OTSC clip • can be used for better approximation of tissue especially when indurated (e.g. fistulae, chronic ulcer) • facilitates targeting lesions, e.g. in the treatment of hemorrhage • allows precise alignment between the target tissue and the application cap • the head of the instrument is made of Nitinol • a working channel diameter of at least 3.2 mm is required when used in combination with the OTSC System KOA Surgical Instruments, G-U, Manual (And Accessories) 2 OTSC Anchor 220tt
31 04260206310266 14 t 200.60 OTSC Proctology is an innovative clipping system to be applied in proctology pro OTSC Proctology is an innovative clipping system to be applied in proctology procedures • it is used for wall closure in the anorectum (e.g. fistulae) • offers three unique advantages: large volume of tissue secured high stability at the lesion site minimal strain on surrounding tissue • exceptional properties and therapeutic functions are based on its special design and material: superelastic Nitinol • material is biocompatible, can be applied as a long-term implant • absorbable U-shaped sutures or the OTSC Proctology Anchor may be used to place the applicator cap precisely on the lesion PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC Proctology
32 04260206310136 12/6 gc 100.27 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
33 04260206310129 14/6 t 100.14 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
34 04260206310112 14/6 a 100.13 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
35 04260206310105 12/6 t 100.12 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
36 04260206310099 12/6 a 100.11 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
37 04260206310082 11/6 t 100.10 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
38 04260206310075 11/6 a 100.09 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
39 04260206310068 14/3 t 100.08 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
40 04260206310051 14/3 a 100.07 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
41 04260206310044 12/3 t 100.06 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
42 04260206310037 12/3 a 100.05 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
43 04260206310020 11/3 t 100.04 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
44 04260206310013 11/3 a 100.03 The OTSC System Set consists of a clip preloaded onto an application cap • a h The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant PKL Hemostatic Metal Clip For The Gi Tract 2 OTSC System Set
45 04260206311003 LiftUp 200.56.01 LiftUp is a thermoreversible injection agent for endoscopic mucosal resection (E LiftUp is a thermoreversible injection agent for endoscopic mucosal resection (EMR) and/or endoscopic submucosal dissection (ESD) PLL Submucosal Injection Agent 2 LiftUp
46 04260206311171 FTRD 13 200.77 FTRD application cap for verification of possible application of the gastroduode FTRD application cap for verification of possible application of the gastroduodenal FTRD® Set and diagnostic FTRD® Set (accessability and ability to pull lesion into the cap). FEI Instrument, Special Lens, For Endoscope 1 gastroduodenal FTRD prOVE Cap
47 04260206311065 3.0 mm 200.53.04 The AqaNife is a monopolar electrosurgical instrument for dissection using flexi The AqaNife is a monopolar electrosurgical instrument for dissection using flexible endoscopes • precise marking of tissue • stable position of the needle without risk of dislocating during the dissection • ceramic socket as stopper and protector • opening in the ceramic socket for flushing and re-injection GEI Electrosurgical, Cutting & Coagulation & Accessories 2 AqaNife
48 04260206311058 2.5 mm 200.53.03 The AqaNife is a monopolar electrosurgical instrument for dissection using flexi The AqaNife is a monopolar electrosurgical instrument for dissection using flexible endoscopes • precise marking of tissue • stable position of the needle without risk of dislocating during the dissection • ceramic socket as stopper and protector • opening in the ceramic socket for flushing and re-injection GEI Electrosurgical, Cutting & Coagulation & Accessories 2 AqaNife
49 04260206311041 2.0 mm 200.53.02 The AqaNife is a monopolar electrosurgical instrument for dissection using flexi The AqaNife is a monopolar electrosurgical instrument for dissection using flexible endoscopes • precise marking of tissue • stable position of the needle without risk of dislocating during the dissection • ceramic socket as stopper and protector • opening in the ceramic socket for flushing and re-injection GEI Electrosurgical, Cutting & Coagulation & Accessories 2 AqaNife
50 04260206311034 1.5 mm 200.53.01 The AqaNife is a monopolar electrosurgical instrument for dissection using flexi The AqaNife is a monopolar electrosurgical instrument for dissection using flexible endoscopes • precise marking of tissue • stable position of the needle without risk of dislocating during the dissection • ceramic socket as stopper and protector • opening in the ceramic socket for flushing and re-injection GEI Electrosurgical, Cutting & Coagulation & Accessories 2 AqaNife
Other products with the same Product Code "GEI"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 03760263240182 Active working element ACMI compatible VA4 (Front load ; Fr26) Working element for FRONT load bipolar electrode CHIRURGIE INNOVATION
2 03760263240175 Passive working element ACMI compatible VP4 (Front load ; Fr26) Working element for FRONT load bipolar electrode CHIRURGIE INNOVATION
3 03760263240168 Active working element OLYMPUS compatible VA3 (Front load ; Fr26 ) Working element for FRONT load bipolar electrode CHIRURGIE INNOVATION
4 03760263240151 Passive working element OLYMPUS compatible VP3 (Front load ; Fr26) Working element for FRONT load bipolar electrode CHIRURGIE INNOVATION
5 03760263240144 Active working element STORZ compatible VA1 (Front load ; Fr26) Working element for FRONT load bipolar electrode CHIRURGIE INNOVATION
6 03760263240137 Passive working element STORZ compatible VP1 (Front load ; Fr26) Working element for FRONT load bipolar electrode CHIRURGIE INNOVATION
7 03760263240120 Active working element OLYMPUS compatible VA3S (square ; Fr26) Working element for SIDE load bipolar electrode CHIRURGIE INNOVATION
8 03760263240113 Passive working element OLYMPUS compatible VP3S (square ; Fr26) Working element for SIDE load bipolar electrode CHIRURGIE INNOVATION
9 03760263240106 Active working element STORZ compatible VA1S (square ; Fr26) Working element for SIDE load bipolar electrode CHIRURGIE INNOVATION
10 03760263240090 Passive working element STORZ compatible VP1S (square ; Fr26) Working element for SIDE load bipolar electrode CHIRURGIE INNOVATION
11 03760263240083 Bipolar electrode / VAPORIZATION STORZ compatible MVVZ (Fr26) Front load bipolar electrode CHIRURGIE INNOVATION
12 03760263240076 Bipolar cutting loop / THICK STORZ compatible MV2Z (Fr26) Front load bipolar electrode CHIRURGIE INNOVATION
13 03760263240069 Bipolar cutting loop / THIN STORZ compatible MV1Z (Fr26) Front load bipolar electrode CHIRURGIE INNOVATION
14 03760263240052 Bipolar electrode / VAPORIZATION OLYMPUS compatible MVV (Fr26) Front load bipolar electrode CHIRURGIE INNOVATION
15 03760263240045 Bipolar cutting loop / THICK OLYMPUS compatible MV2 (Fr26) Front load bipolar electrode CHIRURGIE INNOVATION
16 03760263240038 Bipolar cutting loop / THIN OLYMPUS compatible MV1 (Fr26) Front load bipolar electrode CHIRURGIE INNOVATION
17 03760263240021 Bipolar electrode / VAPORIZATION MVVS (square fitting ; Fr26) Side load bipolar electrode CHIRURGIE INNOVATION
18 03760263240014 Bipolar cutting loop / THICK MV2S (square fitting ; Fr26) Side load bipolar electrode CHIRURGIE INNOVATION
19 03760263240007 Bipolar cutting loop / THIN MV1S (square fitting ; Fr26) Side load bipolar electrode CHIRURGIE INNOVATION
20 03700393301520 IC5330 IC5330 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
21 03700393301445 IK5330 IK5330 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
22 03700393301049 ECS5330 ECS5330 Single use, atraumatic Endoclinch forceps for laparoscopic surgery NA PETERS SURGICAL
23 03700393300899 MD5330 MD5330 Single use, Maryland dissector with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
24 03700393300783 H5330L H5330L Disposable hook with unipolar cautery for endoscopic surgery. NA PETERS SURGICAL
25 03700393300462 5053H 5053H Single use, blunt trocar for laparoscopic surgery NA PETERS SURGICAL
26 03700393300363 C5250 C5250 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
27 03700393300325 CAB3000 CAB3000 single use, monopolar cable NA PETERS SURGICAL
28 03700393300301 11100S 11100S Single use, trocar with protected tip for laparoscopic surgery NA PETERS SURGICAL
29 03700393300288 12100H 12100H Single use, blunt trocar for laparoscopic surgery NA PETERS SURGICAL
30 03700393300264 12100 12100 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
31 03700393300240 12060 12060 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
32 03700393300226 5100 5100 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
33 03700393300202 5068 5068 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
34 03700393300189 5053 5053 Single use, sharp trocar for laparoscopic surgery NA PETERS SURGICAL
35 03700393300165 H5330 H5330 Single use, hook with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
36 03700393300141 G5330 G5330 Single use, grasping forceps with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
37 03700393300127 F5330 F5330 Single use, atraumatic forceps fenestrated with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
38 03700393300103 A5330 A5330 Single use, atraumatic forceps with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
39 03700393300080 D5330 D5330 Single use, dissector with monopolar cautery for laparoscopic surgery NA PETERS SURGICAL
40 03700393300066 T5330 T5330 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
41 03700393300042 C5470 C5470 Single use, monopolar cautery scissors (curved blade) for laparoscopic surgery IN CUT scissors PETERS SURGICAL
42 03665772000091 B-1506 The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder Arm Monopolar hook DEX SURGICAL
43 03665772000084 B-1505 The monopolar maryland are reusable (40 uses) endoscopic instrument. It is conne The monopolar maryland are reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder Arm Monopolar Maryland DEX SURGICAL
44 03665772000077 B-1304 The monopolar scissors are reusable (20 uses) endoscopic instrument. It is conne The monopolar scissors are reusable (20 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder Arm Monopolar scissors DEX SURGICAL
45 03665772000060 B-1301 The arm needle holder is a reusable (40 uses) endoscopic instrument. It is conne The arm needle holder is a reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Protection sleeve (ref. 2090-MDS). Each Arm is composed of a shaft, a connection cover and an articulated instrument followed by the needle holder tip that provides distal mobility.1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder Arm Needle holder DEX SURGICAL
46 03665772000053 P46732 The Sleeve applicator tool purpose is to help the installation of Protection sle The Sleeve applicator tool purpose is to help the installation of Protection sleeve 2090-MDS onto the tip of Arm Needle holder B-1301 Sleeve applicator tool DEX SURGICAL
47 03665772000046 M-1304 Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-13 Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-1304, B-1505 and B-1506 and to remain there for the duration of the surgical procedure. It is provided non-sterile and is single use; it must be sterilize before the use. Its purpose is to protect the gear mechanism from its environment and guarantee the electrical insulation. It prevents the distal part of the arms (except for the tip) from coming into contact with the patient's tissues, thereby preventing the risk of lesions and burning subsequent to such contact. Monopolar protection sleeve DEX SURGICAL
48 03665772000039 2090-MDS Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and to remain there for the duration of the surgical procedure. Its purpose is to protect the gear mechanism from its environment. It also helps prevent the gears from coming into contact with the patient's tissues, thereby preventing the risk of lesion formation subsequent to such mechanical contact. It is provided non-sterile and is single use; it must be sterilize before the use. Protection sleeve DEX SURGICAL
49 03665772000022 P-1302 The DEX Device control handle for left handed is comprised of an ergonomic hand The DEX Device control handle for left handed is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-. Control Handle Left DEX SURGICAL
50 03665772000015 P-1301 The DEX Device control handle is comprised of an ergonomic hand piece that can t The DEX Device control handle is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-. Control handle DEX SURGICAL