No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 04260056885747 6194-1-001 6194-1-010 Simplex® HV is a fast-setting acrylic resin for use in bone surgery. Mixing the Simplex® HV is a fast-setting acrylic resin for use in bone surgery. Mixing the two separate sterile components produces a ductile bone cement which, after hardening, fixes the implant and transfers stresses produced during movement evenly to the bone. Simplex® HV cement powder also contains insoluble zirconium dioxide as an X-ray contrast medium. Simplex® HV does not emit a signal and does not pose a safety risk in a magnetic resonance environment. LOD Bone Cement 2 Simplex HV
2 04260056880759 08.702.017S 08.702.017S Vertecem II is a radio-opaque, injectable acrylic bone cement used for the treat Vertecem II is a radio-opaque, injectable acrylic bone cement used for the treatment of pathological fractures of the vertebral body due to osteoporosis, cancer, or benign lesions using a Vertebroplasty or Kyphoplasty procedure. NDN,LOD Cement, Bone, Vertebroplasty,Bone Cement Vertecem II Cement Kit
3 04260056884412 02-0305 02-0305 Vacuum mixing system for mixing of PMMA bone cements JDZ Mixer, Cement, For Clinical Use 1 EASYMIX pro
4 04260056883231 01-0309 BonOs® Inject is a radiopaque, injectable bone cement for use in spine surgery l BonOs® Inject is a radiopaque, injectable bone cement for use in spine surgery like percutaneous vertebral augmentation during vertebroplasty or kyphoplasty. Mixing the two separate sterile components initially produces a ductile, injectable bone cement which, after hardening in situ, is able to stabilize neoplastic vertebral lesions and vertebral compression fractures. BonOs® Inject cement powder also contains insoluble zirconium dioxide as an X-ray contrast medium. NDN,LOD Cement, Bone, Vertebroplasty,Bone Cement BonOs Inject
5 04260056881565 02-0601 02-0602 ManuMix® is a mixing system for bone cements of low to medium viscosity and subs ManuMix® is a mixing system for bone cements of low to medium viscosity and subsequent transfer in syringes for clinical application. JDZ Mixer, Cement, For Clinical Use 1 ManuMix
6 04260056885761 6195-1-001 6195-1-010 Simplex® HV with Gentamicin is a fast-setting acrylic resin with addition of gen Simplex® HV with Gentamicin is a fast-setting acrylic resin with addition of gentamicin sulfate for use in bone surgery. Mixing the two separate sterile components produces a ductile bone cement which, after hardening, fixes the implant and transfers stresses produced during movement evenly to the bone. Simplex® HV with Gentamicinn cement powder also contains insoluble zirconium dioxide as an X-ray contrast medium. Simplex® HV with Gentamicin does not emit a signal and does not pose a safety risk in a magnetic resonance environment. MBB,LOD Bone Cement, Antibiotic,Bone Cement 2 Simplex HV with Gentamicin
7 04260056885624 01-0117 BonOs® R is a fast-setting acrylic resin for use in bone surgery. Mixing the two BonOs® R is a fast-setting acrylic resin for use in bone surgery. Mixing the two separate sterile components produces a ductile bone cement which, after hardening, fixes the implant and transfers stresses produced during movement evenly to the bone. BonOs® R cement powder also contains insoluble zirconium dioxide as an X-ray contrast medium. BonOs® R does not emit a signal and does not pose a safety risk in a magnetic resonance environment. LOD Bone Cement 2 BonOs R 1x40
Other products with the same Product Codes "MBB, LOD"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10886982262257 07.702.040S 07702040S TRAUMACEM(TM) V+ INJECTABLE BONE CEMENT - STERILE TRAUMACEM SYNTHES GMBH
2 10885380066528 CMT-40-1G CMT-40-1G Orthopaedic cement, medicated CARDINAL HEALTH CARDINAL HEALTH 200, LLC
3 10885380066528 CMT-40-1G CMT-40-1G Orthopaedic cement, medicated CARDINAL HEALTH CARDINAL HEALTH 200, LLC
4 10885380066511 CMT-40-1 CMT-40-1 Orthopaedic cement, non-medicated CARDINAL HEALTH CARDINAL HEALTH 200, LLC
5 10603295174295 5450-50-501 545050501 Smartset GMV HIGH PERFORMANCE GENTAMICIN Medium Viscosity Bone Cement 40g SMARTSET DEPUY (IRELAND)
6 10603295174295 5450-50-501 545050501 Smartset GMV HIGH PERFORMANCE GENTAMICIN Medium Viscosity Bone Cement 40g SMARTSET DEPUY (IRELAND)
7 10603295174288 5450-35-500 545035500 Smartset GHV GENTAMICIN High Viscosity Bone Cement 40g SMARTSET DEPUY (IRELAND)
8 10603295174288 5450-35-500 545035500 Smartset GHV GENTAMICIN High Viscosity Bone Cement 40g SMARTSET DEPUY (IRELAND)
9 10603295174271 5450-32-500 545032500 DEPUY CMW 2 GENTAMICIN Fast Set Bone Cement 20g NA DEPUY (IRELAND)
10 10603295174271 5450-32-500 545032500 DEPUY CMW 2 GENTAMICIN Fast Set Bone Cement 20g NA DEPUY (IRELAND)
11 10603295174264 5450-31-500 545031500 DEPUY CMW 1 GENTAMICIN Bone Cement 40g NA DEPUY (IRELAND)
12 10603295174264 5450-31-500 545031500 DEPUY CMW 1 GENTAMICIN Bone Cement 40g NA DEPUY (IRELAND)
13 10603295168638 3332-040 3332040 DEPUY CMW 3 Medium Viscosity Bone Cement 40g NA DEPUY (IRELAND)
14 10603295168621 3322-020 3322020 DEPUY CMW 2 Fast Set Bone Cement 20g NA DEPUY (IRELAND)
15 10603295168614 3312-040 3312040 DEPUY CMW 1 High Viscosity Bone Cement 40g NA DEPUY (IRELAND)
16 10603295168379 3122-040 3122040 SmartSet HIGH PERFORMANCE MV Medium Viscosity Bone Cement 40g SMARTSET DEPUY (IRELAND)
17 10603295168362 3122-020 3122020 SmartSet HIGH PERFORMANCE MV Medium Viscosity Bone Cement 20g SMARTSET DEPUY (IRELAND)
18 10603295168355 3102-080 3102080 SmartSet ENDURANCE MV Medium Viscosity Bone Cement 80g SMARTSET DEPUY (IRELAND)
19 10603295168355 3102-080 3102080 SmartSet ENDURANCE MV Medium Viscosity Bone Cement 80g SMARTSET DEPUY (IRELAND)
20 10603295168331 3092-040 3092040 SmartSet HV High Viscosity Bone Cement 40g SMARTSET DEPUY (IRELAND)
21 10603295168331 3092-040 3092040 SmartSet HV High Viscosity Bone Cement 40g SMARTSET DEPUY (IRELAND)
22 10603295168324 3092-020 3092020 SmartSet HV High Viscosity Bone Cement 20g SMARTSET DEPUY (IRELAND)
23 10603295168324 3092-020 3092020 SmartSet HV High Viscosity Bone Cement 20g SMARTSET DEPUY (IRELAND)
24 M684141030001 14103000 14103000 ORTHOSET® III BONE CEMENT ORTHOSET® MICROPORT ORTHOPEDICS INC.
25 M684141020001 14102000 14102000 ORTHOSET® II BONE CEMENT ORTHOSET® MICROPORT ORTHOPEDICS INC.
26 M684141010001 14101000 14101000 ORTHOSET® I BONE CEMENT ORTHOSET® MICROPORT ORTHOPEDICS INC.
27 08058964727039 900189 80 Orthopedic bone cement modular spacer for temporary knee prosthesis SpaceFlex Knee G21 SRL
28 08058964726940 900189 70 SpaceFlex Knee G21 SRL
29 08058964726933 900189 60 SpaceFlex Knee G21 SRL
30 08058964726902 900005 15 Disposable custom modular spacer mold SpaceFlex Hip G21 SRL
31 08058964726896 900005 13 Disposable custom modular spacer mold SpaceFlex Hip G21 SRL
32 08058964726889 900005 10 Disposable custom modular spacer mold SpaceFlex Hip G21 SRL
33 08058964726759 800019 800019 Bone Cement OrthoSteady G G21 SRL
34 08058964726759 800019 800019 Bone Cement OrthoSteady G G21 SRL
35 08058964726186 900008 SpaceFlex Hip Instrument Kit is intended to be used in combination with SpaceFle SpaceFlex Hip Instrument Kit is intended to be used in combination with SpaceFlex Hip to mold temporary prosthesis. SpaceFlex Hip Instrument Kit G21 SRL
36 08058964726087 900001 144818 "Disposable cement spacer molds with metal reinforcement stem are indicated for "Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge." SpaceFlex Shoulder G21 SRL
37 08058964726070 900001 124818 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. SpaceFlex Shoulder G21 SRL
38 08058964726063 900001 124215 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. SpaceFlex Shoulder G21 SRL
39 08058964726056 900001 104818 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. SpaceFlex Shoulder G21 SRL
40 08058964726049 900001 104215 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. SpaceFlex Shoulder G21 SRL
41 08058964724977 900001 084215 Disposable cement spacer molds with metal reinforcement stem are indicated for u Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge. SpaceFlex Shoulder G21 SRL
42 08058964723970 800002 Radiopaque Bone Cement G1 40 Radiopaque Bone Cement G21 SRL
43 08058964723819 800039 800039 Radiopaque Bone Cement for vertebral consolidation V-STEADY G21 SRL
44 08058964720245 800036 800036 Radiopaque Bone Cement for vertebral consolidation V-FAST G21 SRL
45 08058964720122 800009 G3A 40 Bone Cement G21 SRL
46 08058964720122 800009 G3A 40 Bone Cement G21 SRL
47 08058964720047 800004 Radiopaque Bone Cement G3 40 Radiopaque Bone Cement G21 SRL
48 08031497002316 KITCEMENT-US Mendec Spine HV is a highly viscous, radio-opaque acrylic resin (PMMA based) for Mendec Spine HV is a highly viscous, radio-opaque acrylic resin (PMMA based) for vertebral augmentation procedures available as a closed mixing unit (the powder and liquid components are enclosed in a syringe-like device). CEMENT KIT TECRES SPA
49 08031497002163 65.01.111US MectaCem-X HV with Gentamicin is a low viscosity antibiotic-loaded polymethylme MectaCem-X HV with Gentamicin is a low viscosity antibiotic-loaded polymethylmethacrylate bone cements. It is composed by two components (40g powder and 14,7g liquid) which are designed for mixing together at the point of use to form the cement. The device is supplied sterile, for single use. MectaCem-X HV with Gentamicin is indicated for the fixation of prostheses to living bone in the second stage of a two-stage revision for total joint arthroplasty after the initial infection has been cleared. MectaCem-X HV with Gentamicin TECRES SPA
50 08031497002163 65.01.111US MectaCem-X HV with Gentamicin is a low viscosity antibiotic-loaded polymethylme MectaCem-X HV with Gentamicin is a low viscosity antibiotic-loaded polymethylmethacrylate bone cements. It is composed by two components (40g powder and 14,7g liquid) which are designed for mixing together at the point of use to form the cement. The device is supplied sterile, for single use. MectaCem-X HV with Gentamicin is indicated for the fixation of prostheses to living bone in the second stage of a two-stage revision for total joint arthroplasty after the initial infection has been cleared. MectaCem-X HV with Gentamicin TECRES SPA