The CMV Probe ASR contains a specific nucleic acid sequence for detection of Cyt
The CMV Probe ASR contains a specific nucleic acid sequence for detection of Cytomegalovirus (CMV). The CMV Probe ASR is designed to detect a region of the MIE gene in the CMV genome. The DNA is synthetically derived.Analyte Specific Reagent. Analytical and performance characteristics are not established.
The QIAcube Connect MDx system is a fully automated, sample preparation system,
The QIAcube Connect MDx system is a fully automated, sample preparation system, processing up to 12 samples using silica spin columns technology. The QIAcube Connect MDx is intended to be used only in combination with QIAGEN kits indicated for use with the QIAcube Connect MDx system for the protocols described in the instructions for use of the respective kits. The system is intended for use by professional users, such as technicians and physicians trained in molecular biological techniques and the operation of the QIAcube Connect IVD system.
The therascreen FGFR RGQ RT-PCR Kit is a real-time, reverse transcription PCR te
The therascreen FGFR RGQ RT-PCR Kit is a real-time, reverse transcription PCR test for the qualitative detection of two point mutations in exon 7 [p.R248C (c.742C>T), p.S249C (c.746C>G)], two point mutations in exon 10 [p.G370C (c.1108G>T) and p.Y373C (c.1118A>G)] and two fusions (FGFR3-TACC3v1 and FGFR3-TACC3v3) in the fibroblast growth factor receptor 3 (FGFR3) gene in RNA samples derived from formalin-fixed paraffin-embedded (FFPE) urothelial tumor tissue. The test is indicated for use as an aid in identifying patients with cases of urothelial cancer (UC) which harbor these alterations and are therefore eligible for treatment with BALVERSA™ (erdafitinib).Specimens are processed using the RNeasy DSP FFPE Kit for manual sample preparation followed by reverse transcription and then automated amplification and detection on the Rotor-Gene Q MDx (US) instrument.
The CMV Primer ASR contains a specific nucleic acid sequence for the amplificati
The CMV Primer ASR contains a specific nucleic acid sequence for the amplification of cytomegalovirus (CMV). The CMV Primer ASR is designed to detect a 105 bp region of the MIE gene in the CMV genome. The DNA is synthetically derived.Analyte Specific Reagent. Analytical and performance characteristics are not established.
The therascreen FGFR RGQ RT-PCR Kit is a real-time, reverse transcription PCR te
The therascreen FGFR RGQ RT-PCR Kit is a real-time, reverse transcription PCR test for the qualitative detection of two point mutations in exon 7 [p.R248C (c.742C>T), p.S249C (c.746C>G)], two point mutations in exon 10 [p.G370C (c.1108G>T) and p.Y373C (c.1118A>G)] and two fusions (FGFR3:TACC3v1 and FGFR3:TACC3v3) in the fibroblast growth factor receptor 3 (FGFR3) gene in RNA samples derived from formalin-fixed paraffin-embedded (FFPE) urothelial tumor tissue. The test is indicated for use as an aid in identifying patients with cases of urothelial cancer (UC) which harbor these alterations and are therefore eligible for treatment with BALVERSA™ (erdafitinib).Specimens are processed using the RNeasy DSP FFPE Kit for manual sample preparation followed by reverse transcription and then automated amplification and detection on the Rotor-Gene Q MDx (US) instrument.
The therascreen PIK3CA RGQ PCR Kit is a real-time qualitative PCR test for the d
The therascreen PIK3CA RGQ PCR Kit is a real-time qualitative PCR test for the detection of 11 mutations in the phosphatidylinositol 3-kinase catalytic subunit alpha (PIK3CA) gene (Exon 7: C420R; Exon 9: E542K, E545A, E545D [1635G>T only], E545G, E545K, Q546E, Q546R; and Exon 20: H1047L, H1047R, H1047Y) using genomic DNA (gDNA) extracted from formalin-fixed, paraffin-embedded (FFPE) breast tumor tissue or circulating tumor DNA (ctDNA) from plasma derived from K2EDTA anticoagulated peripheral whole blood taken from patients with breast cancer. The test is intended to aid clinicians in identifying breast cancer patients who may be eligible for treatment with PIQRAY® (alpelisib) based on a PIK3CA Mutation Detected result. Patients whose FFPE tissue or plasma specimen produces a positive therascreen PIK3CA RGQ PCR Kit test result for the presence of one or more PIK3CA mutations are eligible for treatment with PIQRAY (alpelisib). Patients whose plasma specimen produces a negative result using this test should be reflexed to testing with FFPE tumor tissue for the presence of PIK3CA mutations. FFPE tumor specimens are processed using the QIAamp DSP DNA FFPE Tissue Kit for manual sample preparation. K2EDTA anticoagulated whole peripheral venous blood plasma specimens are processed using the QIAamp DSP Circulating Nucleic Acid Kit for manual sample preparation. For both specimen types, the Rotor-Gene Q (RGQ) MDx (US) instrument is used for automated amplification and detection. The Kit is to be used by trained personnel in a professional laboratory environment.
The therascreen BRAF V600E RGQ PCR Kit is a real-time PCR test for the qualitati
The therascreen BRAF V600E RGQ PCR Kit is a real-time PCR test for the qualitative detection of V600E mutations in the BRAF gene using genomic DNA extracted from formalin-fixed paraffin-embedded (FFPE) human colorectal cancer (CRC) tumor tissue. The therascreen BRAF V600E RGQ PCR Kit is an in vitro diagnostic device intended to be used as an aid in selecting patients with metastatic colorectal cancer (mCRC) whose tumors carry the BRAF V600E mutation for treatment with BRAFTOVI (encorafenib) in combination with cetuximab. The therascreen BRAF V600E RGQ PCR Kit is for use on the Rotor-Gene Q MDx (US)instrument. The therascreen BRAF V600E RGQ PCR Kit is intended for in vitro diagnostic use.
The Idylla™ Console is a computer with a vertically oriented touch-screen and a
The Idylla™ Console is a computer with a vertically oriented touch-screen and a barcode reader placed directly below the touch-screen that communicates with the Idylla™ Instruments. Idylla™ Console and up to eight Idylla™ Instruments constitute the Idylla™ System.
The HSV 1&2 ELITe MGB® Assay is a real-time polymerase chain reaction (PCR) base
The HSV 1&2 ELITe MGB® Assay is a real-time polymerase chain reaction (PCR) based qualitative in vitro diagnostic test for the direct detection and differentiation of Herpes Simplex Virus 1 and 2 (HSV-1 and HSV-2) DNA in cutaneous or mucocutaneous lesion swab specimens from patients with signs and symptoms of HSV-1 or HSV-2 infection.
The product «ELITe InGenius® Waste Box» (Catalog code F2102-000) provides dispos
The product «ELITe InGenius® Waste Box» (Catalog code F2102-000) provides disposable plastic boxes for collecting tip waste generated during the protocol run for extraction from biological samples, realtime set up in association with the «ELITe InGenius®» a fully automated sample-to-result instrument (Catalog code INT030-K).ELITe InGenius® Waste Box is FDA cleared only for use in association with ELITe InGenius® (Catalog code INT030-K) and HSV1&2 ELITe MGB® Assay.
The ELITe InGenius® SP 200 Consumable Set (Catalog number INT032CS) provides con
The ELITe InGenius® SP 200 Consumable Set (Catalog number INT032CS) provides consumables to be used with ELITe InGenius® SP 200 (Catalog number INT032SP200) extraction cartridge for nucleic acid extraction from biological samples, in association with the ELITe InGenius® instrument (Catalog number INT030-K). ELITe InGenius system, is a fully automated molecular diagnostics system performing extraction, purification, amplification and detection.ELITe InGenius® SP 200 Consumable Set is FDA cleared only for use in association with HSV 1&2 ELITe MGB® Assay
The product ELITe InGenius® PCR Cassette (catalog number INT035PCR) provides con
The product ELITe InGenius® PCR Cassette (catalog number INT035PCR) provides consumables to be used in association with the ELITe InGenius® instrument (catalog number INT030-K) for Real Time PCR reactions. ELITe InGenius system, is a fully automated molecular diagnostics system performing extraction, purification, amplification and detection.ELITe InGenius® PCR Cassette is FDA cleared only for use in association with HSV1&2 ELITe MGB® Assay.
The product ELITe InGenius® SP 200 extraction cartridge (catalog number INT032SP
The product ELITe InGenius® SP 200 extraction cartridge (catalog number INT032SP200) provides reagents used in association with the ELITe InGenius® instrument (catalog number INT030-K) to perform extractions and purification of nucleic acids. ELITe InGenius system, is a fully automated molecular diagnostics system performingextraction, purification, amplification and detection.ELITe InGenius SP 200 is FDA cleared only for use in association with ELITe InGenius® (code INT030-K) instrument and HSV1&2 ELITe MGB® Assay.
The ELITe InGenius® system is an in vitro diagnostic (IVD) platform that perform
The ELITe InGenius® system is an in vitro diagnostic (IVD) platform that performs nucleic acid based tests. The ELITe InGenius system is a fully automated device integrating extraction and purification of nucleic acids from multiple sample types, amplification and detection of the target sequence by real-time Polymerase Chain Reaction (PCR), and result interpretation. ELITe InGenius® is FDA cleared only for use in association with HSV 1&2 ELITe MGB® Assay
QuantStudio Real-Time PCR Instrument Qualified by OpGen for use with Acuitas AMR
QuantStudio Real-Time PCR Instrument Qualified by OpGen for use with Acuitas AMR Gene Panel.