The VISUCAM Digital Fundus Camera is suitable for photographing, displaying and
The VISUCAM Digital Fundus Camera is suitable for photographing, displaying and storing data relating to the retina and surrounding parts of the eye beeing examined under mydriatic and non-mydriatic conditions. These photographs assist with the diagnosis and follow-up of eye diseases, which can be visually monitored and photographiacally documented.
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to remove the cortex and clean the capsule bag during human cataract surgery.
The IOLMaster is intended for the biometric determination of ocular measurements
The IOLMaster is intended for the biometric determination of ocular measurements for axial length, anterior chamber depth, corneal radius, white-to-white (WTW), and for the measurement of pupil size and deviation of the visual axis from the center of the pupil. For patients who are candidates for intraocular lens (IOL) implantation, the device also performs calculations to assist physicians in determining the appropriate IOL power and type for implantation.
The FF 450plus is a monocular retina camera for routine use. It is designed to c
The FF 450plus is a monocular retina camera for routine use. It is designed to capture images of the eye, especially the retina area, as well as surrounding areas, to aid diagnosing or monitoring diseases of the eye that may be observed and photographed. If used in combination with dedicated optional equipment (electronic image sensors, digital archiving system) the system allows images to be displayed, stored, manipulated and archived digitally.
The SL 115 Classic Slit Lamp is a AC-powered slit lamp biomicroscope intended fo
The SL 115 Classic Slit Lamp is a AC-powered slit lamp biomicroscope intended for use in eye examination of the anterior eye segment, from the corneal epithelium to the posterior capsule. It is used to aid in the diagnosis of disease or trauma which affect the structural properties of the anterior eye segment. The optional SL cam 5.0 is a digital imaging solution that allows the user to take images and video sequences for documentation purposes of the anterior eye segment during slit lamp examinations.
The products are single use, sterile drapes to cover all surfaces of the main de
The products are single use, sterile drapes to cover all surfaces of the main device with a potential need to get in contact with sterile objects during surgical procedures.
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to remove the cortex and clean the capsule bag during human cataract surgery
This active reusable device is an accessory for ZEISS phaco systems. It has been
This active reusable device is an accessory for ZEISS phaco systems. It has been designed to emulsify and aspirate the eye lens during human eye surgery by phacoemulsification technique.
The SL 120 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use
The SL 120 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of disease or trauma which affect the structural properties of the anterior eye segment.The optional SL cam 5.0 is a digital imaging solution that allows the user to take images and video sequences for documentation purposes of the anterior eye segment during slit lamp examinations.
The VisuMax laser keratome is a femtosecond laser. It generates a beam of ultra-
The VisuMax laser keratome is a femtosecond laser. It generates a beam of ultra-short laser pulses whichare guided through the aperture in the treatment objective .The optical system focuses the laser beam into the corneal tissue.The VisuMax femtosecond laser is indicated for use in ophthalmic surgery for the creation of corneal incisions in patients undergoing the following treatments:• In the creation of a corneal flap in patients undergoing LASIK surgery or other treatment requiring initial lamellar resection of the cornea• In patients undergoing surgery or other treatment requiring initial lamellar resection of the cornea• In the creation of a lamellar cut/resection of the cornea for lamellar keratoplasty• In the creation of a cut/incision for penetrating keratoplasty and corneal harvesting• Surgery or other treatment requiring initial lamellar resection of the cornea to create tunnels for placement of corneal ring segments.Additionally under class III: The VisuMax Femtosecond Laser is indicated for use in small incisionlenticule extraction (SMILE) for the reduction or elimination ofmyopia with or without astigmatism• for spherical refractive error (in minus cylinder format) from -1.00 diopters through -10.00 diopters,• for cylinder from -0.75 diopters through -3.00 diopters,• when refraction spherical equivalent is no greater in magnitude than 10.00 diopters,in patients 22 years of age or older with documentation of stable manifest refraction over the past year as demonstrated by a change in sphere and cylinder of ≤ 0.50 D in magnitude.
HQF,OTL,HNO
Laser, Ophthalmic,Femtosecond Laser System For Refractive Correction,Keratome, Ac-Powered
The SL 130 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use
The SL 130 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of disease or trauma which affect the structural properties of the anterior eye segment.The optional SL cam 5.0 is a digital imaging solution that allows the user to take images and video sequences for documentation purposes of the anterior eye segment during slit lamp examinations.
The Product is a single use sterile accessory kit for the ZEISS phaco and vitreo
The Product is a single use sterile accessory kit for the ZEISS phaco and vitreoretinal systems and has been designed to direct balanced salt solution from irrigation source to the surgical handpieces and to convey the materials removed from the eye to a reservoir during eye surgery on anterior and posterior segments of the human eye.
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to emulsify and aspirate the eye lens during human cataract surgery.(consists of TEST CHAMBER, PHACO TIP and SILICONE SLEEVE)
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to emulsify and aspirate the eye lens during human cataract surgery.(consists of TEST CHAMBER, PHACO TIP and SILICONE SLEEVE).
The IMAGEnet 6 ver. 2.4.0 is a software program that is intended for use in the
The IMAGEnet 6 ver. 2.4.0 is a software program that is intended for use in the collection, storage and management of digital images, patient data and diagnostic data from Topcon devices.
The IMAGEnet 6 ver. 2.3.0 is a software program that is intended for use in the
The IMAGEnet 6 ver. 2.3.0 is a software program that is intended for use in the collection, storage and management of digital images, patient data and diagnostic data from Topcon devices.
The IMAGEnet 6 ver. 2.2.1 is a software program that is intended for use in the
The IMAGEnet 6 ver. 2.2.1 is a software program that is intended for use in the collection, storage and management of digital images, patient data and diagnostic data from Topcon devices.
The IMAGEnet 6 ver. 2.2.0 is a software program that is intended for use in the
The IMAGEnet 6 ver. 2.2.0 is a software program that is intended for use in the collection, storage and management of digital images, patient data and diagnostic data from Topcon devices.
The IMAGEnet 6 ver. 2.1.1 is a software program that is intended for use in the
The IMAGEnet 6 ver. 2.1.1 is a software program that is intended for use in the collection, storage and management of digital images, patient data and diagnostic data from Topcon devices.
The IMAGEnet 6 ver. 2.1.0 is a software program that is intended for use in the
The IMAGEnet 6 ver. 2.1.0 is a software program that is intended for use in the collection, storage and management of digital images, patient data and diagnostic data from Topcon devices.
The IMAGEnet 6 ver. 2.0.3 is a software program that is intended for use in the
The IMAGEnet 6 ver. 2.0.3 is a software program that is intended for use in the collection, storage and management of digital images, patient data and diagnostic data from Topcon devices.
The IMAGEnet 6 ver. 2.0.2 is a software program that is intended for use in the
The IMAGEnet 6 ver. 2.0.2 is a software program that is intended for use in the collection, storage and management of digital images, patient data and diagnostic data from Topcon devices.
The IMAGEnet 6 ver. 2.0 is a software program that is intended for use in the co
The IMAGEnet 6 ver. 2.0 is a software program that is intended for use in the collection, storage and management of digital images, patient data and diagnostic data from Topcon devices.
It is intended for use as a diagnostic device to aid in the check and management
It is intended for use as a diagnostic device to aid in the check and management of ocular diseases such as macular holes, cystoid macular edema, diabetic retinopathy, aged related macular degeneration, and so on
It is intended for use as a diagnostic device to aid in the check and management
It is intended for use as a diagnostic device to aid in the check and management of ocular diseases such as macular holes, cystoid macular edema, diabetic retinopathy, aged related macular degeneration, and so on
A desktop retinal imaging device that can perform ultra-widefield scanning laser
A desktop retinal imaging device that can perform ultra-widefield scanning laser ophthalmoscopy and targeted navigated optical coherence tomography.
The NAVIS-EX image filing software is software that acquires data from the follo
The NAVIS-EX image filing software is software that acquires data from the following NIDEK fundus photography devices and files it for easy transfer to external systems. NAVIS-EX is equipped with functions for image acquiring, image display, image drawing, image processing, image measurement, panorama image creation, stereo image observation, composite image creation, and Follow-Up. (According to the image, available functions are limited.) Image data can be transferred by network or e-mail. NAVIS-EX can construct a network among multiple terminals and refers to and edits data from the clientPC.
The NIDEK Optical Coherence Tomography RS-3000 Advance is an ophthalmic camera t
The NIDEK Optical Coherence Tomography RS-3000 Advance is an ophthalmic camera that allows non-invasive and non-contact observation of the shape of the fundus or retina. Fundus surface images (hereafter referred to as SLO image) are captured with the confocal laser scanning using a near-infrared light source with a wavelength of 785 nm. Cross-sectional images of the retina (hereafter referred to as OCT image) are captured with the optical interferometer using an infrared light source with a wavelength of 880 nm. With the images captured using the RS-3000 Advance, the shape and structure of the fundus or retina can be observed, and diseases can be observed. This system is comprised of the main body for capturing images, a computer (hereafter called PC) for storing and analyzing captured images, PC monitor, and an isolation transformer.In addition, the image filing software NAVIS-EX (hereafter referred to as NAVIS-EX) offers the following features:• Image analysis functions such as 3D/map color display or retinal thickness analysis• Networking for data review or analysis on PCs in separate locations