The VISUCAM Digital Fundus Camera is suitable for photographing, displaying and
The VISUCAM Digital Fundus Camera is suitable for photographing, displaying and storing data relating to the retina and surrounding parts of the eye beeing examined under mydriatic and non-mydriatic conditions. These photographs assist with the diagnosis and follow-up of eye diseases, which can be visually monitored and photographiacally documented.
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to remove the cortex and clean the capsule bag during human cataract surgery.
The IOLMaster is intended for the biometric determination of ocular measurements
The IOLMaster is intended for the biometric determination of ocular measurements for axial length, anterior chamber depth, corneal radius, white-to-white (WTW), and for the measurement of pupil size and deviation of the visual axis from the center of the pupil. For patients who are candidates for intraocular lens (IOL) implantation, the device also performs calculations to assist physicians in determining the appropriate IOL power and type for implantation.
The FF 450plus is a monocular retina camera for routine use. It is designed to c
The FF 450plus is a monocular retina camera for routine use. It is designed to capture images of the eye, especially the retina area, as well as surrounding areas, to aid diagnosing or monitoring diseases of the eye that may be observed and photographed. If used in combination with dedicated optional equipment (electronic image sensors, digital archiving system) the system allows images to be displayed, stored, manipulated and archived digitally.
The SL 115 Classic Slit Lamp is a AC-powered slit lamp biomicroscope intended fo
The SL 115 Classic Slit Lamp is a AC-powered slit lamp biomicroscope intended for use in eye examination of the anterior eye segment, from the corneal epithelium to the posterior capsule. It is used to aid in the diagnosis of disease or trauma which affect the structural properties of the anterior eye segment. The optional SL cam 5.0 is a digital imaging solution that allows the user to take images and video sequences for documentation purposes of the anterior eye segment during slit lamp examinations.
The products are single use, sterile drapes to cover all surfaces of the main de
The products are single use, sterile drapes to cover all surfaces of the main device with a potential need to get in contact with sterile objects during surgical procedures.
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to remove the cortex and clean the capsule bag during human cataract surgery
This active reusable device is an accessory for ZEISS phaco systems. It has been
This active reusable device is an accessory for ZEISS phaco systems. It has been designed to emulsify and aspirate the eye lens during human eye surgery by phacoemulsification technique.
The SL 120 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use
The SL 120 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of disease or trauma which affect the structural properties of the anterior eye segment.The optional SL cam 5.0 is a digital imaging solution that allows the user to take images and video sequences for documentation purposes of the anterior eye segment during slit lamp examinations.
The VisuMax laser keratome is a femtosecond laser. It generates a beam of ultra-
The VisuMax laser keratome is a femtosecond laser. It generates a beam of ultra-short laser pulses whichare guided through the aperture in the treatment objective .The optical system focuses the laser beam into the corneal tissue.The VisuMax femtosecond laser is indicated for use in ophthalmic surgery for the creation of corneal incisions in patients undergoing the following treatments:• In the creation of a corneal flap in patients undergoing LASIK surgery or other treatment requiring initial lamellar resection of the cornea• In patients undergoing surgery or other treatment requiring initial lamellar resection of the cornea• In the creation of a lamellar cut/resection of the cornea for lamellar keratoplasty• In the creation of a cut/incision for penetrating keratoplasty and corneal harvesting• Surgery or other treatment requiring initial lamellar resection of the cornea to create tunnels for placement of corneal ring segments.Additionally under class III: The VisuMax Femtosecond Laser is indicated for use in small incisionlenticule extraction (SMILE) for the reduction or elimination ofmyopia with or without astigmatism• for spherical refractive error (in minus cylinder format) from -1.00 diopters through -10.00 diopters,• for cylinder from -0.75 diopters through -3.00 diopters,• when refraction spherical equivalent is no greater in magnitude than 10.00 diopters,in patients 22 years of age or older with documentation of stable manifest refraction over the past year as demonstrated by a change in sphere and cylinder of ≤ 0.50 D in magnitude.
HQF,OTL,HNO
Laser, Ophthalmic,Femtosecond Laser System For Refractive Correction,Keratome, Ac-Powered
The SL 130 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use
The SL 130 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of disease or trauma which affect the structural properties of the anterior eye segment.The optional SL cam 5.0 is a digital imaging solution that allows the user to take images and video sequences for documentation purposes of the anterior eye segment during slit lamp examinations.
The Product is a single use sterile accessory kit for the ZEISS phaco and vitreo
The Product is a single use sterile accessory kit for the ZEISS phaco and vitreoretinal systems and has been designed to direct balanced salt solution from irrigation source to the surgical handpieces and to convey the materials removed from the eye to a reservoir during eye surgery on anterior and posterior segments of the human eye.
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to emulsify and aspirate the eye lens during human cataract surgery.(consists of TEST CHAMBER, PHACO TIP and SILICONE SLEEVE)
The OxyLight system is a skin care therapy system that that uses multiple therap
The OxyLight system is a skin care therapy system that that uses multiple therapeutic modalities delivered through different attachments or handles. The system includes a panel that irradiates Blue, Red and Yellow LED light for photodynamic therapy and Oxygen spray therapy as well as a microdermabrasion handle.
Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jac
Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jacket with length marking, SMA 905 connector, black protection cap, black bend protection, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jack
Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket with length marking, SMA 905 connector, black protection cap, black bend protection, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber - Radial Emission Fiber 600µm Vein
Radial Emission Fiber Vein, core 550µm, clad 578µm, fiber OD 1400µm, white Tefze
Radial Emission Fiber Vein, core 550µm, clad 578µm, fiber OD 1400µm, white Tefzel Jacket with length marking, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber - Radial Emission Fiber 600µm Stopper
Radial Emission Fiber with Stopper, core 550µm, clad 578µm, fiber OD 1400µm, whi
Radial Emission Fiber with Stopper, core 550µm, clad 578µm, fiber OD 1400µm, white Tefzel Jacket, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, stopper 466mm from distal end, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber - Radial Emission Fiber 400µm Vein
Radial Emission Fiber Vein, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel
Radial Emission Fiber Vein, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket with length marking, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber - Radial Emission Fiber 400µm Stopper
Radial Emission Fiber with Stopper, core 400µm, clad 420µm, fiber OD 900µm, whit
Radial Emission Fiber with Stopper, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, stopper 466mm from distal end, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Ja
Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jacket with length marking, standard SMA905 connector with knurl nut, PVC protection cap, extension sleeve red engraved, black bend protection, LUER adapter, distal conical tip with silica capillary dome, capillary OD 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Corona 360 Fiber, core 550µm, clad 578µm, fiber OD 1400µm, white Vestodur Jacket
Corona 360 Fiber, core 550µm, clad 578µm, fiber OD 1400µm, white Vestodur Jacket with length marking, customized connector, white bend protection, distal conical tip with silica capillary dome, capillary OD 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber, core 320µm, clad 385µm, fiber OD 415µm, polyimide coating,
Laser Surgery Fiber, core 320µm, clad 385µm, fiber OD 415µm, polyimide coating, standard SMA 905 connector with knurl nut, PVC protection cap, extension sleeve red engraved, black bend protection, Silicone tubing OD 2mm, distal flat tip, cleaved, 10cm freestanding fiber, NA 0.22, length 3m +/-0,2m, sterile EO, disposable, single packed,
Laser Surgery Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jack
Laser Surgery Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jacket with length marking, standard SMA 905 connector with knurl nut, PEEK protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, NA 0.22, length 3m +/-0,2m, sterile EO, double packed
Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket,
Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, SMA 905 holmium connector with knurl nut, black protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, 3mm stripped, NA 0.22, length 3m +/-0,2m, sterile EO, disposable, double packed
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, freestanding SMA 905, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop blue 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, freestanding SMA 905, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop green 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop yellow 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop red 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed