The VISUCAM Digital Fundus Camera is suitable for photographing, displaying and
The VISUCAM Digital Fundus Camera is suitable for photographing, displaying and storing data relating to the retina and surrounding parts of the eye beeing examined under mydriatic and non-mydriatic conditions. These photographs assist with the diagnosis and follow-up of eye diseases, which can be visually monitored and photographiacally documented.
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to remove the cortex and clean the capsule bag during human cataract surgery.
The IOLMaster is intended for the biometric determination of ocular measurements
The IOLMaster is intended for the biometric determination of ocular measurements for axial length, anterior chamber depth, corneal radius, white-to-white (WTW), and for the measurement of pupil size and deviation of the visual axis from the center of the pupil. For patients who are candidates for intraocular lens (IOL) implantation, the device also performs calculations to assist physicians in determining the appropriate IOL power and type for implantation.
The FF 450plus is a monocular retina camera for routine use. It is designed to c
The FF 450plus is a monocular retina camera for routine use. It is designed to capture images of the eye, especially the retina area, as well as surrounding areas, to aid diagnosing or monitoring diseases of the eye that may be observed and photographed. If used in combination with dedicated optional equipment (electronic image sensors, digital archiving system) the system allows images to be displayed, stored, manipulated and archived digitally.
The SL 115 Classic Slit Lamp is a AC-powered slit lamp biomicroscope intended fo
The SL 115 Classic Slit Lamp is a AC-powered slit lamp biomicroscope intended for use in eye examination of the anterior eye segment, from the corneal epithelium to the posterior capsule. It is used to aid in the diagnosis of disease or trauma which affect the structural properties of the anterior eye segment. The optional SL cam 5.0 is a digital imaging solution that allows the user to take images and video sequences for documentation purposes of the anterior eye segment during slit lamp examinations.
The products are single use, sterile drapes to cover all surfaces of the main de
The products are single use, sterile drapes to cover all surfaces of the main device with a potential need to get in contact with sterile objects during surgical procedures.
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to remove the cortex and clean the capsule bag during human cataract surgery
This active reusable device is an accessory for ZEISS phaco systems. It has been
This active reusable device is an accessory for ZEISS phaco systems. It has been designed to emulsify and aspirate the eye lens during human eye surgery by phacoemulsification technique.
The SL 120 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use
The SL 120 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of disease or trauma which affect the structural properties of the anterior eye segment.The optional SL cam 5.0 is a digital imaging solution that allows the user to take images and video sequences for documentation purposes of the anterior eye segment during slit lamp examinations.
The VisuMax laser keratome is a femtosecond laser. It generates a beam of ultra-
The VisuMax laser keratome is a femtosecond laser. It generates a beam of ultra-short laser pulses whichare guided through the aperture in the treatment objective .The optical system focuses the laser beam into the corneal tissue.The VisuMax femtosecond laser is indicated for use in ophthalmic surgery for the creation of corneal incisions in patients undergoing the following treatments:• In the creation of a corneal flap in patients undergoing LASIK surgery or other treatment requiring initial lamellar resection of the cornea• In patients undergoing surgery or other treatment requiring initial lamellar resection of the cornea• In the creation of a lamellar cut/resection of the cornea for lamellar keratoplasty• In the creation of a cut/incision for penetrating keratoplasty and corneal harvesting• Surgery or other treatment requiring initial lamellar resection of the cornea to create tunnels for placement of corneal ring segments.Additionally under class III: The VisuMax Femtosecond Laser is indicated for use in small incisionlenticule extraction (SMILE) for the reduction or elimination ofmyopia with or without astigmatism• for spherical refractive error (in minus cylinder format) from -1.00 diopters through -10.00 diopters,• for cylinder from -0.75 diopters through -3.00 diopters,• when refraction spherical equivalent is no greater in magnitude than 10.00 diopters,in patients 22 years of age or older with documentation of stable manifest refraction over the past year as demonstrated by a change in sphere and cylinder of ≤ 0.50 D in magnitude.
HQF,OTL,HNO
Laser, Ophthalmic,Femtosecond Laser System For Refractive Correction,Keratome, Ac-Powered
The SL 130 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use
The SL 130 Slit Lamp is an AC-powered slit lamp biomicroscopes intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of disease or trauma which affect the structural properties of the anterior eye segment.The optional SL cam 5.0 is a digital imaging solution that allows the user to take images and video sequences for documentation purposes of the anterior eye segment during slit lamp examinations.
The Product is a single use sterile accessory kit for the ZEISS phaco and vitreo
The Product is a single use sterile accessory kit for the ZEISS phaco and vitreoretinal systems and has been designed to direct balanced salt solution from irrigation source to the surgical handpieces and to convey the materials removed from the eye to a reservoir during eye surgery on anterior and posterior segments of the human eye.
This single use device is an accessory for ZEISS phaco systems. It has been desi
This single use device is an accessory for ZEISS phaco systems. It has been designed to emulsify and aspirate the eye lens during human cataract surgery.(consists of TEST CHAMBER, PHACO TIP and SILICONE SLEEVE)
Schiotz tonometer with inclined scale, manufactured and certified by Gulden Opht
Schiotz tonometer with inclined scale, manufactured and certified by Gulden Ophthalmic, supplied with case, tables, zero test block and 5.5, 7.5, 10 and 15 gram weights
Schiotz tonometer weight - 5.5 gram, must send entire unit in for service when o
Schiotz tonometer weight - 5.5 gram, must send entire unit in for service when ordering this replacement part, service charge included in price listed
Allen-Schiotz tonometer with Plunger Retractor and inclined scale, manufactured
Allen-Schiotz tonometer with Plunger Retractor and inclined scale, manufactured and certified by Gulden Ophthalmics, supplied with case, tables, zero test block and 5.5, 7.5, 10 and 15 gram weights
Manual tonometer used to gauge internal pressure within the eye. An allen wrench
Manual tonometer used to gauge internal pressure within the eye. An allen wrench can be used to adjust weight settings.
Manual Tonometer is used to gauge the internal pressure of the eye using weights
Manual Tonometer is used to gauge the internal pressure of the eye using weights and a tonometer tip.
It is a manual device intended for measurement of intraocular pressure by applan
It is a manual device intended for measurement of intraocular pressure by applanation (applying a small flat disk to the cornea) to aid the diagnosis of glaucoma
It is a manual device intended for measurement of intraocular pressure by applan
It is a manual device intended for measurement of intraocular pressure by applanation (applying a small flat disk to the cornea) to aid the diagnosis of glaucoma
It is a manual device intended for measurement of intraocular pressure by applan
It is a manual device intended for measurement of intraocular pressure by applanation (applying a small flat disk to the cornea) to aid the diagnosis of glaucoma
The Icare ic200 (TA031) tonometer is a hand-held, battery operated device, which
The Icare ic200 (TA031) tonometer is a hand-held, battery operated device, which measures intraocular pressure (IOP) without the need for topical anesthesia. The Icare ic200 tonometer measures the IOP by utilizing the rebound method. The Icare ic200 tonometer is intended to be used for the measurement of intraocular pressure of the human eye. Icare ic200 allows IOP measurement of patients in all positions between sitting and supine positions. IOP measurement result can be transferred to printer or to a PC via Bluetooth connection.