HMO 51000-USA #SQUADROX-i Small Ad.+Filter /Small Adult. Filter
70106.7895
QUADROX-i Small Adult Microporous membrane oxygenator with integrated arterial f
QUADROX-i Small Adult Microporous membrane oxygenator with integrated arterial filter, SOFTLINE coated, and a screw connector
BEQ-HMO 51000 #SQUADR-i Small Adult +Fi. / Small Adult, Filter; BIOLINE Coating
70106.7911
QUADROX-i Small Adult Microporous Membrane Oxygenator with integrated arterial f
QUADROX-i Small Adult Microporous Membrane Oxygenator with integrated arterial filter, BIOLINE coated, with a screw connector
BEQ-HMO 50000-USA #SQUADR-i Small Ado.Fi / Small Adult, BIOLINE
70106.7905
QUADROX-i Small Adult Microporous Membrane Oxygenator, BIOLINE coated, without f
QUADROX-i Small Adult Microporous Membrane Oxygenator, BIOLINE coated, without filter, with a screw connector
QUADROX-i Small Adult Microporous Membrane Oxygenator, SOFTLINE coated, without
QUADROX-i Small Adult Microporous Membrane Oxygenator, SOFTLINE coated, without filter, with a screw connector
Venous Hardshell Cardiotomy Reservoir, Adult, non-coated, with cardiotomy filter
Venous Hardshell Cardiotomy Reservoir, Adult, non-coated, with cardiotomy filter, without screw connector, Sterile. The Venous Hardshell Cardiotomy Reservoirs are developed for the use in the field cardiopulmonary bypass operation. They are used as blood buffer in the extracorporeal circuit and as collecting and defoaming device for sucked blood. The vacuum-tight version of the VHK reservoir can also be employed postoperatively as drainage and auto-transfusion reservoir (e.g., for thorax drainage) to return the autologous blood to the patient which was removed from the thorax for the volume exchange.
Venous Hardshell Cardiotomy Reservoir, Adult, Vacuum-tight, with SOFTLINE Coatin
Venous Hardshell Cardiotomy Reservoir, Adult, Vacuum-tight, with SOFTLINE Coating, without screw connector, Sterile. The Venous Hardshell Cardiotomy Reservoirs are developed for the use in the field cardiopulmonary bypass operation. They are used as blood buffer in the extracorporeal circuit and as collecting and defoaming device for sucked blood. The vacuum-tight version of the VHK reservoir (VHK 71000) can also be employed postoperatively as drainage and auto-transfusion reservoir (e.g., for thorax drainage) to return the autologous blood to the patient which was removed from the thorax for the volume exchange.
The Paragon Adult Maxi PMP oxygenator is a hollow fiber membrane oxygenator inte
The Paragon Adult Maxi PMP oxygenator is a hollow fiber membrane oxygenator intended for physiologic gas exchange in adults and small adults undergoing cardiopulmonary bypass surgery. The integrated heat exchanger makes it possible to regulate the blood temperature.
Pall LeukoGuard LG Leukocyte Reduction Arterial Blood Filter for Extracorporeal
Pall LeukoGuard LG Leukocyte Reduction Arterial Blood Filter for Extracorporeal Service (with Bypass Loop)
The Novalung sLA Membrane Lung is a gas exchange device that allows for oxygen a
The Novalung sLA Membrane Lung is a gas exchange device that allows for oxygen and carbon dioxide gas exchange to occur by diffusion across a polymethylpentene (PMP) hollow fibre membrane material. Used in conjunction with a heart-lung machine along with a separate venous reservoir and heat exchanger, the sLA Membrane Lung can be used in open-heart surgery.
hilite 800 LT hollow fiber oxygenator for neonates and infants, model 0L01
MW 6208 0L01
The Medos hilite 800 LT oxygenator is indicated for use in procedures requiring
The Medos hilite 800 LT oxygenator is indicated for use in procedures requiring the extracorporeal oxygenation of and carbon dioxide removal from human blood. It is designed to operate at a blood flow rate of 0.2 to 0.8 liters per minute.
hilite 1000 hollow fiber oxygenator for neonates and infants, model 0001
MW 6208 0001
The Medos hilite 1000 oxygenator is indicated for use in procedures requiring th
The Medos hilite 1000 oxygenator is indicated for use in procedures requiring the extracorporeal oxygenation of and carbon dioxide removal from human blood. It is designed to operate at a blood flow rate of 0.2 to 1.0 liters per minute.
hilite 2400 LT hollow fiber oxygenator for pediatrics, model 0L01
MW 6205 0L01
The Medos hilite 2400 LT oxygenator is indicated for use in procedures requiring
The Medos hilite 2400 LT oxygenator is indicated for use in procedures requiring the extracorporeal oxygenation of and carbon dioxide removal from human blood. It is designed to operate at a blood flow rate up to 2.4 liters per minute.
hilite 2800 hollow fiber oxygenator for pediatrics, model 0001
MW 6205 0001
The Medos hilite 2800 oxygenator is indicated for use in procedures requiring th
The Medos hilite 2800 oxygenator is indicated for use in procedures requiring the extracorporeal oxygenation of and carbon dioxide removal from human blood. It is designed to operate at a blood flow rate up to 2.8 liters per minute.