The centrifugal control unit provides the local display and control mechanism fo
The centrifugal control unit provides the local display and control mechanism for the centrifugal motor and disposable pump and serves as the interface between the centrifugal motor and the rest of the system. The local display indicates the motor speed, flow rate, and safety, status and error messages. The pump can be controlled from either the CCM or from the control knob on the control unit.
The large roller pump is a peristaltic pump with a 6 inch (15 cm) raceway that c
The large roller pump is a peristaltic pump with a 6 inch (15 cm) raceway that can be used for arterial, cardioplegia, vent, and suction applications. A universl tube clamp mechanism accommodates a variety of tubing sizes, including dual tube sets.
The small roller pump is a peristaltic pump with a 4 inch (10 cm) raceway that c
The small roller pump is a peristaltic pump with a 4 inch (10 cm) raceway that can be used for arterial, cardioplegia, vent, and suction applications. A universl tube clamp mechanism accommodates a variety of tubing sizes, including dual tube sets.
Central Control Monitor (CCM) combines an embedded computer, a touch screen, and
Central Control Monitor (CCM) combines an embedded computer, a touch screen, and a Graphical User Interface (GUI) to provide a centralized display of system information and onscreen control of all system devices
The air sensor is a non-invasive, ultrasonic sensor that can detect air bubbles
The air sensor is a non-invasive, ultrasonic sensor that can detect air bubbles in the perfusion circuit. This is the 3/8"x3/32" sensor.
The occluder head provides a computer-controlled tube occlusion mechanism. The o
The occluder head provides a computer-controlled tube occlusion mechanism. The occluder head is controlled via signals received from the occluder module. The occulder head can be detached from the occluder module.
A PC Card contained in one of the CCM card slots that stores a system activity l
A PC Card contained in one of the CCM card slots that stores a system activity log and is used by authorized service personnel
The Configuration PC Card is used to backup System 1 Perfusion Configurations. T
The Configuration PC Card is used to backup System 1 Perfusion Configurations. These cards also allow the renaming and deletion of PerfusionConfigurations.
This kit is provided to store and house miscellaneous items: roller pump knob co
This kit is provided to store and house miscellaneous items: roller pump knob colored caps, wire markers and tags, spare fasteners, tools that may be needed, and replacement air filter.
The occluder module serves as the interface between the occluder head and the sy
The occluder module serves as the interface between the occluder head and the system. The occluder system is controlled from the CCM, and can be configured to respond to primary pump events.
The Interface Module for CDI 500 Module provides the interface between the CDI™
The Interface Module for CDI 500 Module provides the interface between the CDI™ 500 Blood Parameter Monitoring System and the APS1. The module communicates the CDI 500 monitor values to the system for display on the CCM.
The Interface Module for CDI 100 provides the interface between a CDI ™ 100 or C
The Interface Module for CDI 100 provides the interface between a CDI ™ 100 or CDI™ 100 Saturation/Hematocrit Monitor and the APS1. The module communicates the CDI monitor values to the system for display on the CCM.
The RS-232 Interface Module provides the interface between the RS-232 protocol d
The RS-232 Interface Module provides the interface between the RS-232 protocol data acquistion software and the system. The module outputs system data to the data acquisition software such as Tlink Data management Software.
The pressure module serves as the interface between up to two pressure transduce
The pressure module serves as the interface between up to two pressure transducers and the system. This module monitors signals from the pressure transducers and communicates pressure values, alerts, and alarms to the system.
The level detect module serves as the interface between the level sensor and the
The level detect module serves as the interface between the level sensor and the system. This module monitors level sensors mounted on a hardsheel blood reserviour and communicates any alerts or alarms to the system.
The Air Bubble Detect (ABD) module is the interface between an air sensor and th
The Air Bubble Detect (ABD) module is the interface between an air sensor and the system. The ABD module monitors the air sensor and communicates any alarms to the system.
Central Control Monitor (CCM) combines an embedded computer, a touch screen, and
Central Control Monitor (CCM) combines an embedded computer, a touch screen, and a Graphical User Interface (GUI) to provide a centralized display of system information and onscreen control of all system devices.
The flowmeter module provides the interface between the flow sensor and the syst
The flowmeter module provides the interface between the flow sensor and the system. The module processes the signals necessary to compute fluid flow values. Those flow values are then communicated to the system. Flowmeter values are displayed on the CCM and, if assigned, on a pump's local display.
System base using a 220V-240V, 7A (circuit breaker), 50/60 Hz (10A power source
System base using a 220V-240V, 7A (circuit breaker), 50/60 Hz (10A power source required) power source
System base using a 100V-120V, 15A (circuit breaker), 50/60 Hz (20A power source
System base using a 100V-120V, 15A (circuit breaker), 50/60 Hz (20A power source required) power source
The electronic gas blender is an optional module that integrates into the APS1 c
The electronic gas blender is an optional module that integrates into the APS1 chassis. It accepts inputs of medical grade oxygen and air, or oxygen and 95/5 (a blend of 95% oxygen and 5% carbon dioxide), and allows the ser to control and regulate the gas output to an oxygenator. A built-in oxygen analyzer measures the oxygen content of the blended gas and provides the information to the system for display on the CCM.
The centrifugal control unit provides the local display and control mechanism fo
The centrifugal control unit provides the local display and control mechanism for the centrifugal pump and serves as the interface between the centrifugal motor and the rest of the heart-lung system.
Roller Pump (6" Blue). The large roller pump is a peristaltic pump with a 6 inch
Roller Pump (6" Blue). The large roller pump is a peristaltic pump with a 6 inch (15 cm) raceway that can be used for arterial, cardioplegia, vent, and suction applications. A universal tub clamp mechanism accommodates a variety of tubing sizes, including dual tube sets.
Roller Pump (4" Blue). The small roller pump is a peristaltic pump with a 4 inch
Roller Pump (4" Blue). The small roller pump is a peristaltic pump with a 4 inch (10 cm) raceway that can be used for arterial, cardioplegia, vent, and suction applications. A universal tub clamp mechanism accommodates a variety of tubing sizes, including dual tube sets.
Roller pump hand cranks used to rotate the roller pump occlusion mechanism durin
Roller pump hand cranks used to rotate the roller pump occlusion mechanism during an electrical power failure. These hand cranks can be used on either the large 6" or the small 4" roller pumps.
Ultrasonic couplant used to facilitate the transmission of sound energy between
Ultrasonic couplant used to facilitate the transmission of sound energy between the level sensor and the reservoir.
The air sensor is a non-invasive, ultrasonic sensor that can detect air bubbles
The air sensor is a non-invasive, ultrasonic sensor that can detect air bubbles in the perfusion circuit. This is the 3/8"x3/32" sensor.
The level sensor is an ultrasonic transducer that is mounted on a hardshell bloo
The level sensor is an ultrasonic transducer that is mounted on a hardshell blood reservoir and detects the presence or absence of blood or prime solution at the point of detection. Red.
The level sensor is an ultrasonic transducer that is mounted on a hardshell bloo
The level sensor is an ultrasonic transducer that is mounted on a hardshell blood reservoir and detects the presence or absence of blood or prime solution at the point of detection. Yellow.
Ultrasonic couplant used to facilitate the transmission of sound energy between
Ultrasonic couplant used to facilitate the transmission of sound energy between the flow sensor and extracorporeal tubing.
Manual drive motor used to rotate the disposable centrifugal pump in the event
Manual drive motor used to rotate the disposable centrifugal pump in the event of electrical power loss.
The centrifugal motor is the drive mechanism necessary to pump fluid through a d
The centrifugal motor is the drive mechanism necessary to pump fluid through a disposable centrifugal pump which is magnetically coupled to the motor.
The air sensor is a non-invasive, ultrasonic sensor that can detect air bubbles
The air sensor is a non-invasive, ultrasonic sensor that can detect air bubbles in the perfusion circuit. This is the 3/8"x3/32" sensor.
8000 Perfusion System Arterial Monitor Providing Temperature and Pressure Measur
8000 Perfusion System Arterial Monitor Providing Temperature and Pressure Measurement Display.
The flow sensor is a non-invasive ultrasonic transducer used to measure fluid fl
The flow sensor is a non-invasive ultrasonic transducer used to measure fluid flow. Includes ultrasonic coupling gel.
The air sensor is a non-invasive, ultrasonic sensor that can detect air bubbles
The air sensor is a non-invasive, ultrasonic sensor that can detect air bubbles in the perfusion circuit. This is the 1/4"x3/32" sensor. Includes cable and holder.