Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and
Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and to remain there for the duration of the surgical procedure. Its purpose is to protect the gear mechanism from its environment. It also helps prevent the gears from coming into contact with the patient's tissues, thereby preventing the risk of lesion formation subsequent to such mechanical contact. It is provided non-sterile and is single use; it must be sterilize before the use.
The arm needle holder is a reusable (40 uses) endoscopic instrument. It is conne
The arm needle holder is a reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Protection sleeve (ref. 2090-MDS). Each Arm is composed of a shaft, a connection cover and an articulated instrument followed by the needle holder tip that provides distal mobility.1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder
Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-13
Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-1304, B-1505 and B-1506 and to remain there for the duration of the surgical procedure. It is provided non-sterile and is single use; it must be sterilize before the use. Its purpose is to protect the gear mechanism from its environment and guarantee the electrical insulation. It prevents the distal part of the arms (except for the tip) from coming into contact with the patient's tissues, thereby preventing the risk of lesions and burning subsequent to such contact.
The DEX Device control handle for left handed is comprised of an ergonomic hand
The DEX Device control handle for left handed is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-.
The console or control unit contains the DEX Device operating system. The front
The console or control unit contains the DEX Device operating system. The front surface contains indicator lights, buttons, an emergency stop button and a connection port
The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected
The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder
The monopolar scissors are reusable (20 uses) endoscopic instrument. It is conne
The monopolar scissors are reusable (20 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder
The Sleeve applicator tool purpose is to help the installation of Protection sle
The Sleeve applicator tool purpose is to help the installation of Protection sleeve 2090-MDS onto the tip of Arm Needle holder B-1301
The DEX Device control handle is comprised of an ergonomic hand piece that can t
The DEX Device control handle is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-.
Cook, Dimpled Vaporization Roller 24FR, 3mm For Use With Storz Double Stem Resec
Cook, Dimpled Vaporization Roller 24FR, 3mm For Use With Storz Double Stem Resectoscope(24, 27FR)
Cook, Coagulating Perforated Resector 27FR For Use With Storz Double Stem Resect
Cook, Coagulating Perforated Resector 27FR For Use With Storz Double Stem Resectoscope (27FR)
Cook, Coagulating Perforated Resector 24FR For Use With Storz Double Stem Resect
Cook, Coagulating Perforated Resector 24FR For Use With Storz Double Stem Resectoscope (24FR)
Cook, Dimpled Vaporization Roller 24FR, 3mm For Use With Olympus OES Resectoscop
Cook, Dimpled Vaporization Roller 24FR, 3mm For Use With Olympus OES Resectoscope(24, 26, 28FR)
Cook, Dimpled Vaporization Roller 24FR, 3mm For Use With Storz Single Stem Resec
Cook, Dimpled Vaporization Roller 24FR, 3mm For Use With Storz Single Stem Resectoscope(24, 27FR)
Cook, Coagulating Perforated Resector 27FR For Use With Storz Single Stem Resect
Cook, Coagulating Perforated Resector 27FR For Use With Storz Single Stem Resectoscope(27FR)
Cook, Coagulating Perforated Resector 24FR For Use With Storz Single Stem Resect
Cook, Coagulating Perforated Resector 24FR For Use With Storz Single Stem Resectoscope(24FR)
Cook, Dimpled Vaporization Roller 24FR, 3mm For Use With ACMI USA/Elite Resectos
Cook, Dimpled Vaporization Roller 24FR, 3mm For Use With ACMI USA/Elite Resectoscope(24, 26, 28FR)