No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 03665772000039 | 2090-MDS | Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and Protection sleeve 2090-MDS is designed to be placed on the Needle holder arm and to remain there for the duration of the surgical procedure. Its purpose is to protect the gear mechanism from its environment. It also helps prevent the gears from coming into contact with the patient's tissues, thereby preventing the risk of lesion formation subsequent to such mechanical contact. It is provided non-sterile and is single use; it must be sterilize before the use. | GEI | Electrosurgical, Cutting & Coagulation & Accessories | 2 | Protection sleeve | |
2 | 03665772000084 | B-1505 | The monopolar maryland are reusable (40 uses) endoscopic instrument. It is conne The monopolar maryland are reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder | GEI | Electrosurgical, Cutting & Coagulation & Accessories | 2 | Arm Monopolar Maryland | |
3 | 03665772000060 | B-1301 | The arm needle holder is a reusable (40 uses) endoscopic instrument. It is conne The arm needle holder is a reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Protection sleeve (ref. 2090-MDS). Each Arm is composed of a shaft, a connection cover and an articulated instrument followed by the needle holder tip that provides distal mobility.1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder | GEI | Electrosurgical, Cutting & Coagulation & Accessories | 2 | Arm Needle holder | |
4 | 03665772000046 | M-1304 | Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-13 Monopolar protection sleeve is designed to be installed onto Monopolar Arms B-1304, B-1505 and B-1506 and to remain there for the duration of the surgical procedure. It is provided non-sterile and is single use; it must be sterilize before the use. Its purpose is to protect the gear mechanism from its environment and guarantee the electrical insulation. It prevents the distal part of the arms (except for the tip) from coming into contact with the patient's tissues, thereby preventing the risk of lesions and burning subsequent to such contact. | GEI | Electrosurgical, Cutting & Coagulation & Accessories | 2 | Monopolar protection sleeve | |
5 | 03665772000022 | P-1302 | The DEX Device control handle for left handed is comprised of an ergonomic hand The DEX Device control handle for left handed is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-. | GEI | Electrosurgical, Cutting & Coagulation & Accessories | 2 | Control Handle Left | |
6 | 03665772000008 | E-1301 | The console or control unit contains the DEX Device operating system. The front The console or control unit contains the DEX Device operating system. The front surface contains indicator lights, buttons, an emergency stop button and a connection port | GEI | Electrosurgical, Cutting & Coagulation & Accessories | 2 | Control Unit | |
7 | 03665772000091 | B-1506 | The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected The monopolar hook are reusable (40 uses) endoscopic instrument. It is connected to the control handle and is used with the single-use Monopolar Protection sleeve (ref. M-1304). Each Arm is composed of an insulated shaft, a connection cover and an articulated instrument that provides distal mobility1. Tilting the tip with respect to the axis of the shaft2. Rotation of the tip around its own axis3. Opening-closing the tip/needle holder | GEI | Electrosurgical, Cutting & Coagulation & Accessories | 2 | Arm Monopolar hook | |
8 | 03665772000053 | P46732 | The Sleeve applicator tool purpose is to help the installation of Protection sle The Sleeve applicator tool purpose is to help the installation of Protection sleeve 2090-MDS onto the tip of Arm Needle holder B-1301 | GEI | Electrosurgical, Cutting & Coagulation & Accessories | 2 | Sleeve applicator tool | |
9 | 03665772000015 | P-1301 | The DEX Device control handle is comprised of an ergonomic hand piece that can t The DEX Device control handle is comprised of an ergonomic hand piece that can turn on its own axis thanks to the comfort joint. This axis can also allow the user to perform a complete manual prono-supination movement without moving his shoulder.The control handle has command buttons that activate the different degrees of freedom or the Arm. The three axes are motorized: Open/Close, Tilt (Left/Right), Rotation+/Rotation-. | GEI | Electrosurgical, Cutting & Coagulation & Accessories | 2 | Control handle |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | B3315851022 | 5851022 | 10MM Glassman Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
2 | B331585101845 | 5851018-45 | Long Retrograde Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
3 | B3315851018 | 5851018 | Retrograde Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
4 | B331585100645 | 5851006-45 | Long Sharp Tooth Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
5 | B3315851006 | 5851006 | Sharp Tooth Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
6 | B331585100545 | 5881005-45 | Long Claw Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
7 | B3315851005 | 5851005 | Claw Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
8 | B3315851004 | 5851004 | 10MM Babcock Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
9 | B331585100245 | 5851002-45 | Long Gall Bladder Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
10 | B3315851002 | 5851002 | Gall Bladder Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
11 | B331585100145 | 5851001-45 | Long Tissue Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
12 | B3315851001 | 5851001 | Tissue Grasping Forceps | Signature | SILEX MEDICAL, LLC | |
13 | B2702610210 | 26-1021 | Cameron-Miller | CAMERON-MILLER INC | ||
14 | B264ATI0140 | ATI-014 | ATI-014 | Insulation and Continuity Tester | NA | CONTROLE GENERAL INFORMATIQUE B.F. INC |
15 | B177953970 | 95397 | 10mm x 33cm Cannula with Holes. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
16 | B1779458L0 | 9458L | 10mm x 33cm Pool Suction Cannula. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
17 | B1779457L0 | 9457L | 5mm x 44cm cannula with holes. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
18 | B1779455L00 | 9455L-0 | 10mm x 33cm Outer Cannula without Holes. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
19 | B1779455L0 | 9455L | 10mm x 33cm Outer Cannula with Holes. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
20 | B1779453L20 | 9453L-2 | 5mm x 33cm Outer Cannula with Holes WT.03. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
21 | B1779453L00 | 9453L-0 | 5mm x 33cm Outer Cannula without Holes. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
22 | B1779453L0 | 9453L | 5mm x 33cm Outer Cannula with Holes. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
23 | B1779452L0 | 9452L | 5mm x 29cm Hydro-Dissection Cannula. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
24 | B1779451L00 | 9451L-0 | 5mm x 27.4cm Outer Cannula without Holes. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
25 | B1779451L0 | 9451L | 5mm x 27.4cm Cannula with Holes. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
26 | B1779450L0 | 9450L | Dual Trumpet Valve Handle with Parallel valve. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
27 | B1779440F0270 | 9440F027 | 5mm x 33cm Non-conductive Outer Cannula. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
28 | B1779440F0250 | 9440F025 | Sealing End Cap, Non-conductive. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
29 | B1779440F0 | 9440F | Non-conductive Dual Trumpet Valve Handle. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
30 | B17793620 | 9362 | Bipolar Retractable/Rotatable Electrode Ball. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
31 | B17793610 | 9361 | Bipolar Retractable/Rotatable Electrode Needle. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
32 | B17793600 | 9360 | Bipolar Retractable/Rotatable Electrode L-hook. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
33 | B17793580 | 9358 | Monopolar Cable for Retractable/Rotatable Electrodes. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
34 | B1779354010 | 9354-01 | Monopolar Retractable/Rotatable Ball Electrode (2mm tip). | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
35 | B1779353010 | 9353-01 | Monopolar Retractable/Rotatable Electrode Needle. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
36 | B1779352010 | 9352-01 | Monopolar Retractable/Rotatable Electrode Right Angle. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
37 | B1779351010 | 9351-01 | Monopolar Retractable/Rotatable Electrode Hook. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
38 | B1779350010 | 9350-01 | Monopolar Retractable/Rotatable Electrode Spatula. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
39 | B17793312 | 9331 | Tuohy-Borsst Adapter for 1,000-2,300u fiber (package of 10). | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
40 | B17793302 | 9330 | Tuohy-Borsst Adapter for 600-1,000u fiber (package of 10). | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
41 | B1779315L0 | 9315L | Trumpet Valve Piston. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
42 | B1779314L0 | 9314L | Trumpet Valve Upper Cap with Spring. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
43 | B1779313L0 | 9313L | Trumpet Valve Lower Cap. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
44 | B1779310100 | 9310-10 | Cleaning Brush, 10mm. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
45 | B17793100 | 9310 | Cleaning Brush, 5mm. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
46 | B17793070 | 9307 | Adapter to connect Davol, Karl Storz, and American Hydro Surgical Cannulas to St Adapter to connect Davol, Karl Storz, and American Hydro Surgical Cannulas to Stainless Steel ACCU-Surg Dual Trumpet Valve. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
47 | B1779306L0 | 9306L | Replacement O-ring kit. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
48 | B1779305L0 | 9305L | End cap with Luer Fitting. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
49 | B1779304L0 | 9304L | Sealing End Cap. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL | |
50 | B1779303010 | 9303-01 | Internal Cannula, 2.4mm x 33cm. | Accu-Beam | TRANSAMERICAN TECHNOLOGIES INTERNATIONAL |