The Piccolo® AmLyte 13 , used with the Piccolo Xpress® chemistry analyzer, is in
The Piccolo® AmLyte 13 , used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, amylase, aspartate aminotransferase (AST), calcium, c-reactive protein (CRP), creatine kinase, creatinine, glucose, potassium, sodium, total bilirubin and blood urea nitrogen (BUN) in lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The Abaxis CRP method is not intended for high sensitivity CRP measurement.
The Piccolo® MetLac 12 Panel reagent disc, used with the Piccolo Xpress® chemist
The Piccolo® MetLac 12 Panel reagent disc, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of albumin, calcium, chloride, creatinine, glucose, lactate, magnesium, phosphorus, potassium, sodium, total carbon dioxide and blood urea nitrogen (BUN) in lithium heparinized whole blood or lithium heparinized plasma in a clinical laboratory setting or point-of-care location.
The Piccolo® MetLyte Plus CRP reagent disc, used with the Piccolo Xpress® chemis
The Piccolo® MetLyte Plus CRP reagent disc, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of c-reactive protein (CRP), chloride, creatine kinase, creatinine, glucose, potassium, sodium, total carbon dioxide and blood urea nitrogen (BUN) in lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The Abaxis CRP method is not intended for high sensitivity CRP measurement.
The Piccolo® Basic Metabolic Panel Plus, used with the Piccolo blood chemistry a
The Piccolo® Basic Metabolic Panel Plus, used with the Piccolo blood chemistry analyzer or Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of calcium, chloride, creatinine, glucose, lactate dehydrogenase, magnesium, potassium, sodium, total carbon dioxide, and blood urea nitrogen in a clinical laboratory setting or point-of-care location. This disc is for testing heparinized plasma and serum, only.
The Piccolo® Comprehensive Metabolic Panel, used with the Piccolo® blood chemist
The Piccolo® Comprehensive Metabolic Panel, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), aspartate aminotransferase (AST), calcium, chloride, creatinine, glucose, potassium, sodium, total bilirubin, total carbon dioxide, total protein, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® Renal Function Panel, used with the Piccolo® blood chemistry analyz
The Piccolo® Renal Function Panel, used with the Piccolo® blood chemistry analyzer or the PiccoloXpress® chemistry analyzer is intended to be used for the in vitro quantitative determination of albumin, calcium, chloride, creatinine, glucose, phosphorus, potassium, sodium, total carbon dioxide and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® Basic Metabolic Panel, used with the Piccolo blood chemistry analyz
The Piccolo® Basic Metabolic Panel, used with the Piccolo blood chemistry analyzer or the PiccoloXpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of calcium, chloride, creatinine, glucose, potassium, sodium, total carbon dioxide, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® MetLyte 8 Panel, used with the Piccolo® blood chemistry analyzer or
The Piccolo® MetLyte 8 Panel, used with the Piccolo® blood chemistry analyzer or the PiccoloXpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of chloride, creatine kinase, creatinine, glucose, potassium, sodium, total carbon dioxide and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® Electrolyte Panel, used with the Piccolo® blood chemistry analyzer
The Piccolo® Electrolyte Panel, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of chloride, potassium, sodium, and total carbon dioxide in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.