A single 3cc transducer connected to a 20 drops, 60" tube Adset. The patient lin
A single 3cc transducer connected to a 20 drops, 60" tube Adset. The patient line is connected with a 48" pressure tube and a 12" pressure tube via 3-way White stopcocks.
Interface Cable to interface Transducer to Monitor. It has a 10-pin monitor conn
Interface Cable to interface Transducer to Monitor. It has a 10-pin monitor connector and the cable length is 150"
Interface Cable to interface Transducer to Monitor. It has a 6-pin monitor conne
Interface Cable to interface Transducer to Monitor. It has a 6-pin monitor connector and the cable length is 150"
A Safedraw Septum connected to a 5cc Restricted Syringe stops at 2cc via a 60” P
A Safedraw Septum connected to a 5cc Restricted Syringe stops at 2cc via a 60” Pressure Tubing. It has a 12” Pressure tubing on the patient side and a colour set.
A standalone 60 drops, 60" tube 1-way Adset packs with a Critiflo assembled with
A standalone 60 drops, 60" tube 1-way Adset packs with a Critiflo assembled with Velcro strap & Adhesive pad. It is connected to a 3-way OFF white stopcock and a 12' Female/ Male Pressure tubing. It also includes a separately packed 2x male protective caps.
A non flushing transducer, 36" Male/Male Pressure Tubing and 2 x 4-Way stopcocks
A non flushing transducer, 36" Male/Male Pressure Tubing and 2 x 4-Way stopcocks. A separately packed 2x male protective caps.
A 2-way 20 drops,60" tubing length each AdSet connected with 2x 3cc transducers
A 2-way 20 drops,60" tubing length each AdSet connected with 2x 3cc transducers at each end. 1 channel is connected with a septum with a 5cc syringe with touchguard stops at 3cc via a 48" & 6" Pressure Tubing. The patient side connects with a 24", 1-Way stopcock & a 6" Small Bore Tubes. The other line connects directly to the 3cc transducer, a 48" & a 12" Pressure Tubes. It includes a separately packed 3xmale & 3xfemale protective caps..
1-way 20 drops, 60" Adset connected with a 3cc Transducer. The blood sampling li
1-way 20 drops, 60" Adset connected with a 3cc Transducer. The blood sampling line has a 24" Small Bore tube , a 1-way stopcock and another 6" small bore tube connect to the Septum Device. The other end of the device connects to a 3-way Red and a 3-way White stopcocks , a 6" Pressure Tubing which cis connected to a 5cc Restricted Syringe with touchguard stops at 3cc.
A 3-way 20 drops,60" tubing length each AdSet connected with 3x 3cc transducers
A 3-way 20 drops,60" tubing length each AdSet connected with 3x 3cc transducers at each end. 1 channel is connected with a septum with a 5cc syringe with touchguard stops at 3cc via a 48" & 6" Pressure Tubing & a 24" & 6" small bore tube from Patient. The other 2 lines connects directly to the 3cc transducer each, a 3-way stopcock and a 72" Pressure Tubing and a 3-way yellow stopcock for one line and a blue 3-way stopcock on the other line. . It includes a separately packed 10xmale & 10xfemale protective caps.
A 3-way 20 drops,60" tubing length each AdSet connected with 3x 3cc transducers
A 3-way 20 drops,60" tubing length each AdSet connected with 3x 3cc transducers at each end. 1 channel is connected with a septum with a 5cc syringe with touchguard stops at 2cc via a 48" & 6" Pressure Tubing & a 12" pressure Tubing from Patient. The other 2 lines connects directly to the 3cc transducer each, a 3-way stopcock and a 6" Pressure Tubing. The 3rd line has an additional 3-Way stopcock to the 6" Pressure Tubing. It includes a separately packed 4xmale & 4xfemale protective caps.
Single 1-way 60 drops, 60inch tube length Adset connected to a 3cc transducer. T
Single 1-way 60 drops, 60inch tube length Adset connected to a 3cc transducer. The zeroing stopcock of the transducer is connected with a septum with a 84" pressure tubing and a 12" pressure tubing. The safedraw set comes with a 5cc syringe with touchguard stops at 2cc. It includes a separately packed 2x male protective caps and a colour Label Set.
a single 3cc transducer connected to a 20 drops, 60" tube Adset. Patient line is
a single 3cc transducer connected to a 20 drops, 60" tube Adset. Patient line is connected to a 6" Prressure tube via a 2-way red stopcock with its side port connected to 3-way white stopcock and a 6" pressure tube.
2x 3cc transducers, 1x 20 drops, 60" tube Adset & 2x 6" Pressure Tubing, each co
2x 3cc transducers, 1x 20 drops, 60" tube Adset & 2x 6" Pressure Tubing, each connected to a port of a 5-Gang Multiport. The middle port connects directly with a 20 drops, 60" Adset. The other 4 ports, each connects with a 6" Pressure Tubing with clamp. The 2 x 3cc transducers are individually connected to these tubings. The zeroing stopcock of transducer in port # 1 connects with a 12" Pressure tubing, with red tape for identification, It has a 72" Pressure tubing connected via s 3-way red stopcocks. Port #2, transducer is connected with a 12" Pressure tubing identified with Yellow tape and a 3-Way yellow stopcock. Port 4 & 5, each connected with 6" pressure Tubing. It also include a TBG, transducer mounting plate
A 3-way white stopcock connects to a 12" presure tubing. It includes a separatel
A 3-way white stopcock connects to a 12" presure tubing. It includes a separately packed 2x male protective caps.
A single line 3cc transducer connected to a 72" Pressure tube and a 12" tube wit
A single line 3cc transducer connected to a 72" Pressure tube and a 12" tube with stopcocks. It includes a separately packed 3x male & 1x female protective caps and a Colour Set.
a 2-way Adset of tube lengths 60" with 1 line connected to a 3cc transducer and
a 2-way Adset of tube lengths 60" with 1 line connected to a 3cc transducer and pressure tubing of lengths 72" and 12" and stopcocks. The other line is left open for other connection. It includes a separately packed 3xmale, 1x Female protective caps and a Colour Set
A 30 cc transducer connected with a 48" pressure tubing and a 3-Way White stopco
A 30 cc transducer connected with a 48" pressure tubing and a 3-Way White stopcock. It has a separately packed 2-xmale protective caps.
A single 3cc transducer connected to a 20 drops, 60" Adset. The other side conne
A single 3cc transducer connected to a 20 drops, 60" Adset. The other side connected with a 48" Pressure tubing and a 3-way White stopcock
A single line 3cc transducer connected to a 20 drops, 60" tube Adset. The other
A single line 3cc transducer connected to a 20 drops, 60" tube Adset. The other end of the transducer is connected to a 12" pressure tubing via 3-way red stopcock.
A single 3cc transducer connected to a 20 drops, 60" tube Adset. The patient lin
A single 3cc transducer connected to a 20 drops, 60" tube Adset. The patient line is connected with a 48" pressure tube and a 12" pressure tube via 3-way White stopcocks.
A single 3cc transducer connected to a 20 drops, 60" tube AdSet. patient line is
A single 3cc transducer connected to a 20 drops, 60" tube AdSet. patient line is connected to a 12" Pressure Tube and a 72" Pressure tube via 3-way stopcock. It also includes a separately packed 3xmale & 1x Female fittings protective caps and a Label Set.
4x 3cc transducers, each connects to a port of a 5-Gang Multiport. The middle po
4x 3cc transducers, each connects to a port of a 5-Gang Multiport. The middle port connects directly with a 20 drops, 60" Adset. The other 4 ports, each connects with a 6" Pressure Tubing with clamp. The 4 x 3cc transducers are individually connected to these tubings. The zeroing stopcock of transducer in port # 1 connects with a 12" Pressure tubing, with red tape for identification, It has a 60" &12" Pressure tubings connect to it via 2 separate 3-way red stopcocks. Port #2, transducer is connected with a 24" Pressure tubing identified with Yellow tape and a 3-Way yellow stopcock. Port # 4, with its transducer connects to a Blue taped 24" pressure tubing and a 3-Way blue stopcock. Port # 5 connects with a transducer.