Other products from "PHILIPS MEDICAL SYSTEMS NEDERLAND B.V."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00884838108899 300007314091 HD 8Ch WRIST ARRAY (Receive Only) MOS Coil, Magnetic Resonance, Specialty 2 GE HEALTHCARE
2 00884838055322 781341 Magnetic Resonance Equipment LNI,LNH System, nuclear magnetic resonance spectroscopic,System, nuclear magnetic resona System, nuclear magnetic resonance spectroscopic,System, nuclear magnetic resonance imaging 2 Ingenia 1.5T
3 00884838106970 6 830089 Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
4 00884838104570 ClarifEye - 1 002120 Software medical device. Intended for use by professional healthcare providers a Software medical device. Intended for use by professional healthcare providers as an intra-operative image-guidance tool used during surgical and interventional therapy. OWB,LLZ,JAK,OLO Interventional Fluoroscopic X-Ray System,System, Image Processing, Radiological, Interventional Fluoroscopic X-Ray System,System, Image Processing, Radiological,System, X-Ray, Tomography, Computed,Orthopedic Stereotaxic Instrument 2 ClarifEye
5 00884838101890 StentBoost Live - 2 001017 Software medical device, used with a Philips Interventional X-Ray System. Provid Software medical device, used with a Philips Interventional X-Ray System. Provides real-time enhanced visualization of stents in coronary vessels. Supports the user in placing and deploying stents. OWB,LLZ Interventional Fluoroscopic X-Ray System,System, Image Processing, Radiological 2 StentBoost Live
6 00884838100107 5 830089 Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
7 00884838099272 Azurion 7 B20 722226 Biplane Interventional X-Ray System with floor-mounted frontal stand (20-inch fl Biplane Interventional X-Ray System with floor-mounted frontal stand (20-inch flat detector), ceiling-mounted lateral stand (12-inch or 15-inch flat detector) and optional interface for an OR table. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 Azurion
8 00884838095250 4.2 830089 Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
9 00884838085268 Azurion 7 M20 722079 Monoplane Interventional X-Ray System. A ceiling or floor-mounted monoplane syst Monoplane Interventional X-Ray System. A ceiling or floor-mounted monoplane system with a 20-inch flat detector. Optionally the ceiling-mounted configuration has an interface for an OR table OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 Azurion
10 00884838085220 2.2 Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
11 00884838093072 4.1 98960612681X Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
12 00884838091429 3.2 98960612660X Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
13 00884838090668 Onvision system 453561943492 Intended to be used during peripheral nerve block procedures. Tracks the positio Intended to be used during peripheral nerve block procedures. Tracks the position of the B.Braun Onvision needle tip position on the ultrasound image by overlaying a circle at the given location. IYO System, Imaging, Pulsed Echo, Ultrasonic 2 Onvision system
14 00884838087460 3.1 98960612483X Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
15 00884838085251 Azurion 7 M12 722078 Monoplane Interventional X-Ray System. A ceiling or floor-mounted monoplane syst Monoplane Interventional X-Ray System. A ceiling or floor-mounted monoplane system with a 12-inch flat detector. OWB,JAA Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified 2 Azurion
16 00884838085770 2.3 98960612341x Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
17 00884838084544 Philips Hemodynamic Application - 1 002010 Software medical device. Intended for use by professional healthcare providers f Software medical device. Intended for use by professional healthcare providers for physiologic/hemodynamic monitoring, medical data processing and analytical assessment. MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms) 2 Philips Hemodynamic Application
18 00884838080812 StentBoost Live - 1 001017 Software medical device, used with a Philips Interventional X-Ray System. Provid Software medical device, used with a Philips Interventional X-Ray System. Provides real-time enhanced visualization of stents in coronary vessels. Supports the user in placing and deploying stents. OWB,LLZ Interventional Fluoroscopic X-Ray System,System, Image Processing, Radiological 2 StentBoost Live
19 00884838076730 1.2 Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
20 00884838075214 2.1 Cardiovascular Image and Information Management Solution (CVIS) LLZ System, image processing, radiological 2 IntelliSpace Cardiovascular
21 00884838059269 StentBoost - 4 001007 Software medical device, used with a Philips Interventional X-Ray System. Provid Software medical device, used with a Philips Interventional X-Ray System. Provides high resolution visualization of stents in vessels. Supports the user in placing and deploying stents. OWB,LLZ Interventional Fluoroscopic X-Ray System,System, Image Processing, Radiological 2 StentBoost
22 00884838059238 MR-CT Roadmap - 1 001004 Software medical device, used with a Philips Interventional X-Ray System. Extens Software medical device, used with a Philips Interventional X-Ray System. Extension of 3D-RA. Provides live 3D image guidance for navigating endovascular devices through vascular structures. OWB,LLZ,JAK Interventional Fluoroscopic X-Ray System,System, Image Processing, Radiological, Interventional Fluoroscopic X-Ray System,System, Image Processing, Radiological,System, X-Ray, Tomography, Computed 2 MR-CT Roadmap
23 00884838059191 Interventional Workspot - 1 001000 Software medical device hosting platform, used with a Philips Interventional X-R Software medical device hosting platform, used with a Philips Interventional X-Ray System. Provides common functionalities (e.g. import / export, data handling) for other software medical devices. LLZ,OWB System, Image Processing, Radiological,Interventional Fluoroscopic X-Ray System 2 Interventional Workspot
24 00884838083325 728231 JAK System, x-ray, tomography, computed 2 Brilliance CT
25 00884838114388 300009321831 Medial Array Coil VT MOS Coil, Magnetic Resonance, Specialty 2 DUNLEE SENITNELLE
26 00884838108646 Ingenia 1.5T 782140 Enables trained physicians to obtain cross-sectional and spectroscopic images of Enables trained physicians to obtain cross-sectional and spectroscopic images of internal structures of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with spin. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
27 00884838108639 Ingenia Ambition S 782139 Enables trained physicians to obtain cross-sectional and spectroscopic images of Enables trained physicians to obtain cross-sectional and spectroscopic images of internal structures of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with spin. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
28 00884838108622 Ingenia Ambition X 782138 Enables trained physicians to obtain cross-sectional and spectroscopic images of Enables trained physicians to obtain cross-sectional and spectroscopic images of internal structures of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with spin. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
29 00884838108615 Ingenia Elition S 782137 Enables trained physicians to obtain cross-sectional and spectroscopic images of Enables trained physicians to obtain cross-sectional and spectroscopic images of internal structures of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with spin. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
30 00884838108608 Ingenia Elition X 782136 Enables trained physicians to obtain cross-sectional and spectroscopic images of Enables trained physicians to obtain cross-sectional and spectroscopic images of internal structures of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with spin. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
31 00884838104129 Ingenia Elition X 782119 The Ingenia Elition X with the gradient and RF designs, as well as Compressed SE The Ingenia Elition X with the gradient and RF designs, as well as Compressed SENSE delivers on superb image quality, improves patient handling setup time and combines this with accelerations in both 2D- and 3D scanning. LNH System, nuclear magnetic resonance imaging 2 Ingenia
32 00884838099715 Ingenia 1.5T 781315 LNH,LNI System, nuclear magnetic resonance imaging,System, nuclear magnetic resonance sp System, nuclear magnetic resonance imaging,System, nuclear magnetic resonance spectroscopic 2 Ingenia
33 00884838099500 HA FlexTrak II 989710008732 The HA FlexTrak II is Height-adjustable to facilitate easy patient transfer and The HA FlexTrak II is Height-adjustable to facilitate easy patient transfer and allows patient preparation for an examination while the previous patient is being scanned. Positioning of coils, positioning aids, monitoring and triggering equipment can be done outside the examination room. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
34 00884838099494 Tabletop extender 989603008792 A moveable tabletop which combined with the standard table top enables a maximum A moveable tabletop which combined with the standard table top enables a maximum field of view of 200cm. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
35 00884838099487 Trolley 989603008226 The Patient Trolley Frame is a stainless steel frame with four wheels for easy t The Patient Trolley Frame is a stainless steel frame with four wheels for easy transportation of the patient positioned on the system's tabletop. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
36 00884838099470 HA FlexTrak 989710006412 The HA FlexTrak is Height-adjustable to facilitate easy patient transfer and all The HA FlexTrak is Height-adjustable to facilitate easy patient transfer and allows patient preparation for an examination while the previous patient is being scanned. Positioning of coils, positioning aids, monitoring and triggering equipment can be done outside the examination room. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
37 00884838099463 FlexTrak 989710006402 The FlexTrak allows patient preparation for an examination while the previous pa The FlexTrak allows patient preparation for an examination while the previous patient is being scanned. Positioning of coils, positioning aids, monitoring and triggering equipment can be done outside the examination room. LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
38 00884838099456 Acoustic Hood 989603022784 "The Achieva acoustic hood is designed to be used with the SENSE Pediatric Head "The Achieva acoustic hood is designed to be used with the SENSE Pediatric Head Spine coil and the SENSE Pediatric Body/Cardiac coil and their mattresses.The acoustic will provide good acoustic noise damping for vulnerable neonatal patients requiring MR examinations.Premature patients are scanned while their acoustic sensory system is still in development and should be protected. Very small children will not always tolerate a headset." LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
39 00884838099449 Acoustic Hood 989603020982 "The Achieva acoustic hood is designed to be used with the SENSE Pediatric Head "The Achieva acoustic hood is designed to be used with the SENSE Pediatric Head Spine coil and the SENSE Pediatric Body/Cardiac coil and their mattresses.The acoustic will provide good acoustic noise damping for vulnerable neonatal patients requiring MR examinations.Premature patients are scanned while their acoustic sensory system is still in development and should be protected. Very small children will not always tolerate a headset." LNH System, Nuclear Magnetic Resonance Imaging 2 Ingenia
40 00884838098343 Ingenia Ambition S 782108 Ingenia Ambition S LNH System, nuclear magnetic resonance imaging 2 Ingenia
41 00884838098336 Ingenia Elition X 782107 Ingenia Elition X LNH System, nuclear magnetic resonance imaging 2 Ingenia
42 00884838098329 Ingenia Elition S 782106 Ingenia Elition S LNH System, nuclear magnetic resonance imaging 2 Ingenia
43 00884838099340 AltaTrack equipment 4322 070 2535 X The AltaTrack equipment is a visualization device with Fiber Optic RealShape (FO The AltaTrack equipment is a visualization device with Fiber Optic RealShape (FORS) technology. Its function is to create a 3D image in real time of an AltaTrack Guidewire and/or AltaTrack Catheter and overlay it on real-time or pre-recorded 2D fluoroscopy images and/or on pre-operative 3D CT images, if available.The AltaTrack equipment comprises software and hardware components (such as lasers, optical components, computer hardware, electrical and optical cabling), and a single-use, sterile, detachable component. DQK Computer, Diagnostic, Programmable 2 AltaTrack
44 00884838099043 Ingenia 1.5T 782115 Enables trained physicians to obtain cross-sectional and spectroscopic images of Enables trained physicians to obtain cross-sectional and spectroscopic images of internal structures of the head, body or extremities, in any orientation, representing the spatial distribution of protons or other nuclei with LNH System, nuclear magnetic resonance imaging 2 Ingenia
45 00884838098350 Ingenia Ambition X 782109 Ingenia Ambition X LNH System, nuclear magnetic resonance imaging 2 Ingenia
46 00884838095083 Smartpath to dStream for 3.0T 781270 LNH,LNI System, nuclear magnetic resonance imaging,System, nuclear magnetic resonance sp System, nuclear magnetic resonance imaging,System, nuclear magnetic resonance spectroscopic 2 Ingenia
47 00884838098312 Ingenia 3.0T CX 782105 We’ve designed Ingenia 3.0T CX with the performance that helps you explore with We’ve designed Ingenia 3.0T CX with the performance that helps you explore with confidence, perform advanced clinical imaging that supports referrals, and conduct routine imaging efficiently. Thanks in part to exceptional Qua LNH System, nuclear magnetic resonance imaging 2 Ingenia
48 00884838098299 Ingenia 3.0T 782103 Ingenia 3.0T LNH System, nuclear magnetic resonance imaging 2 Ingenia
49 00884838098275 Ingenia 1.5T 782101 Ingenia 1.5T LNH System, nuclear magnetic resonance imaging 2 Ingenia
50 00884838095076 Smartpath to dStream for 1.5T 781260 MRDD Equipment LNI,LNH System, nuclear magnetic resonance spectroscopic,System, nuclear magnetic resona System, nuclear magnetic resonance spectroscopic,System, nuclear magnetic resonance imaging 2 Ingenia
Other products with the same Product Codes "OWB, LLZ, JAK"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04260495880389 3.8.0 The product mint Lesion helps qualified radiologists with the image-based diagno The product mint Lesion helps qualified radiologists with the image-based diagnosis and treatment response assessment of oncological diseases. Fields of application are radiological diagnosis and follow-up examinations in oncology, as well as clinical or pharmaceutical drug trials across a defined group of patients.mint Lesion implements various radiological guidelines and response evaluation criteria, such as RECIST (Response Evaluation Criteria In Solid Tumors). This also includes the assessment of the stage of oncological disease (staging) and the objective response to therapy (e.g. timepoint response / overall response). The timepoint response is an empirical measure to evaluate therapy success according to the response criteria in use. It is mainly used to assess patient cohorts in the course of clinical trials of novel therapy agents. The timepoint response may differ from a radiological assessment of response to therapy and must not be used as a surrogate.mint Lesion allows for the documentation of size and assessment of changes in size of solid tumors described by the respective criteria that are monitored by means of radiological imaging (computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine (PET, NM), digital radiography (XR, CR)).mint Lesion follows the typical workflow of follow-up examinations, from assessment to reporting, and enables the integration of a clinical-radiological software environment (PACS, Picture Archiving and Communication System). Assessment results can be exported into different electronical formats and processed further by other applications. mintLesion™ MINT MEDICAL GMBH
2 04260495880372 3.7.0 The product mint Lesion helps qualified radiologists with the image-based diagno The product mint Lesion helps qualified radiologists with the image-based diagnosis and treatment response assessment of oncological diseases. Fields of application are radiological diagnosis and follow-up examinations in oncology, as well as clinical or pharmaceutical drug trials across a defined group of patients. mint Lesion implements various radiological guidelines and response evaluation criteria, such as RECIST (Response Evaluation Criteria In Solid Tumors). This also includes the assessment of the stage of oncological disease (staging) and the objective response to therapy (e.g. timepoint response / overall response). The timepoint response is an empirical measure to evaluate therapy success according to the response criteria in use. It is mainly used to assess patient cohorts in the course of clinical trials of novel therapy agents. The timepoint response may differ from a radiological assessment of response to therapy and must not be used as a surrogate. mint Lesion allows for the documentation of size and assessment of changes in size of solid tumors described by the respective criteria that are monitored by means of radiological imaging (computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine (PET, NM), digital radiography (XR, CR)). mint Lesion follows the typical workflow of follow-up examinations, from assessment to reporting, and enables the integration of a clinical-radiological software environment (PACS, Picture Archiving and Communication System). Assessment results can be exported into different electronical formats and processed further by other applications. mintLesion® MINT MEDICAL GMBH
3 04260495880365 3.6.0 The product mint Lesion helps qualified radiologists with the image-based diagno The product mint Lesion helps qualified radiologists with the image-based diagnosis and treatment response assessment of oncological diseases. Fields of application are radiological diagnosis and follow-up examinations in oncology, as well as clinical or pharmaceutical drug trials across a defined group of patients. mint Lesion implements various radiological guidelines and response evaluation criteria, such as RECIST (Response Evaluation Criteria In Solid Tumors). This also includes the assessment of the stage of oncological disease (staging) and the objective response to therapy (e.g. timepoint response / overall response). The timepoint response is an empirical measure to evaluate therapy success according to the response criteria in use. It is mainly used to assess patient cohorts in the course of clinical trials of novel therapy agents. The timepoint response may differ from a radiological assessment of response to therapy and must not be used as a surrogate. mint Lesion allows for the documentation of size and assessment of changes in size of solid tumors described by the respective criteria that are monitored by means of radiological imaging (computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine (PET, NM), digital radiography (XR, CR)). mint Lesion follows the typical workflow of follow-up examinations, from assessment to reporting, and enables the integration of a clinical-radiological software environment (PACS, Picture Archiving and Communication System). Assessment results can be exported into different electronical formats and processed further by other applications. mintLesion® MINT MEDICAL GMBH
4 04260495880358 3.5.0 The product mint Lesion helps qualified radiologists with the image-based diagno The product mint Lesion helps qualified radiologists with the image-based diagnosis and treatment response assessment of oncological diseases. Fields of application are radiological diagnosis and follow-up examinations in oncology, as well as clinical or pharmaceutical drug trials across a defined group of patients. mint Lesion implements various radiological guidelines and response evaluation criteria, such as RECIST (Response Evaluation Criteria In Solid Tumors). This also includes the assessment of the stage of oncological disease (staging) and the objective response to therapy (e.g. timepoint response / overall response). The timepoint response is an empirical measure to evaluate therapy success according to the response criteria in use. It is mainly used to assess patient cohorts in the course of clinical trials of novel therapy agents. The timepoint response may differ from a radiological assessment of response to therapy and must not be used as a surrogate. mint Lesion allows for the documentation of size and assessment of changes in size of solid tumors described by the respective criteria that are monitored by means of radiological imaging (computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine (PET, NM), digital radiography (XR, CR)). mint Lesion follows the typical workflow of follow-up examinations, from assessment to reporting, and enables the integration of a clinical-radiological software environment (PACS, Picture Archiving and Communication System). Assessment results can be exported into different electronical formats and processed further by other applications. mintLesion® MINT MEDICAL GMBH
5 04260495880341 3.4.0 The product mint Lesion helps qualified radiologists with the image-based diagno The product mint Lesion helps qualified radiologists with the image-based diagnosis and treatment response assessment of oncological diseases. Fields of application are radiological diagnosis and follow-up examinations in oncology, as well as clinical or pharmaceutical drug trials across a defined group of patients. mint Lesion implements various radiological guidelines and response evaluation criteria, such as RECIST (Response Evaluation Criteria In Solid Tumors). This also includes the assessment of the stage of oncological disease (staging) and the objective response to therapy (e.g. timepoint response / overall response). The timepoint response is an empirical measure to evaluate therapy success according to the response criteria in use. It is mainly used to assess patient cohorts in the course of clinical trials of novel therapy agents. The timepoint response may differ from a radiological assessment of response to therapy and must not be used as a surrogate. mint Lesion allows for the documentation of size and assessment of changes in size of solid tumors described by the respective criteria that are monitored by means of radiological imaging (computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine (PET, NM), digital radiography (XR, CR)). mint Lesion follows the typical workflow of follow-up examinations, from assessment to reporting, and enables the integration of a clinical-radiological software environment (PACS, Picture Archiving and Communication System). Assessment results can be exported into different electronical formats and processed further by other applications. mintLesion® MINT MEDICAL GMBH
6 04260483290183 2.4 2.4.0.229939, Release date: 2021-09-032.4.1.252491, Release date: 2022-03-25 DynaCAD Lung MEVIS MEDICAL SOLUTIONS AG
7 04260483290176 1.7 1.7.0.228241, Release date: 2021-03-181.7.1.252491, Release date: 2022-03-25 Veolity MEVIS MEDICAL SOLUTIONS AG
8 04260483290169 3.2 DynaSuite Neuro MEVIS MEDICAL SOLUTIONS AG
9 04260483290114 2.3 DynaCAD Lung MEVIS MEDICAL SOLUTIONS AG
10 04260483290091 1.4 Veolity MEVIS MEDICAL SOLUTIONS AG
11 04260483290077 3.1 DynaSuite Neuro MEVIS MEDICAL SOLUTIONS AG
12 04260483290053 2.2 DynaCAD Lung MEVIS MEDICAL SOLUTIONS AG
13 04260483290039 1.3 Veolity MEVIS MEDICAL SOLUTIONS AG
14 04260476810015 3 Software for biopsy needle guide planning and tracking. BioJet Target MEDICAL TARGETING TECHNOLOGIES GMBH
15 04260476510038 v1 (US) aycan mobile AYCAN DIGITALSYSTEME GMBH
16 04260476510021 v3 aycan workstation AYCAN DIGITALSYSTEME GMBH
17 04260456230147 4.80.0 CHILI PACS is a picture archiving and communication system with image processing CHILI PACS is a picture archiving and communication system with image processing functions to support physicians in diagnosis and treatment planning. CHILI PACS CHILI GMBH
18 04260456230130 4.78.0 CHILI PACS CHILI GMBH
19 04260456230123 4.76.0 CHILI PACS CHILI PACS CHILI GMBH
20 04260456230116 4.74.0 CHILI PACS CHILI GMBH
21 04260456230109 4.72.0 CHILI PACS CHILI GMBH
22 04260456230093 4.70.0 CHILI PACS CHILI PACS CHILI GMBH
23 04260456230086 4.68.0 CHILI PACS 4.68.0 CHILI PACS CHILI GMBH
24 04260456230079 4.66.0 CHILI PACS 4.66.0 CHILI PACS CHILI GMBH
25 04260456230062 4.64.0 CHILI PACS 4.64.0 CHILI PACS CHILI GMBH
26 04260456230055 4.62.0 CHILI PACS 4.62.0 CHILI PACS CHILI GMBH
27 04260456230048 4.60 CHILI GmbH CHILI GMBH
28 04260456230031 4.58 CHILI PACS 4.58 CHILI PACS CHILI GMBH
29 04260456230024 4.56 CHILI PACS 4.56 CHILI PACS CHILI GMBH
30 04260456230017 4.54 CHILI PACS 4.54 CHILI PACS CHILI GMBH
31 04260456230000 4.52 CHILI PACS 4.52 CHILI PACS CHILI GMBH
32 G090AIM11 1 AIM1 AI Metrics is a thin client software application used with general purpose compu AI Metrics is a thin client software application used with general purpose computing hardware for the display and visualization of medical image data, supporting images and anatomical datasets, such as CT and MR. AI Metrics is designed as a workflow automation application with analytical tools to help the user assess, categorize and document the extent of a disease and/or tumor response to therapy in accordance with user selected standards (e.g. RECIST 1.1) and assess changes in imaging findings over multiple time-points. AI Metrics supports the interpretation and evaluation of examinations and follow up documentation of findings within healthcare institutions, for example, in Radiology, Oncology, and other Medical Imaging environments. AI Metrics functionality provides for communication, storage, processing, rendering, and display of DICOM compliant image data derived from various sources, navigation through images, selection of regions of interest, generation of information from those regions, evaluation in accordance with user selected standards, and generation of a structured report. The user controls these functions with a system of interactive menus and semi-automated or manual workflow automation tools, including: • Manual annotation tools for users to select regions of interest (ROIs), • Semi-automatic lesion segmentation suggestions for user-selected ROIs, • Automatic measurement and display of long and short axis of segmented lesions, • Automatic tabulation and summation of measurements,• Semi-automatic lesion labelling suggestions for anatomical location (organ, body region, and laterality), • Automatic calculation of quantitative and qualitative metrics using annotation data in accordance with the selected criteria, and • Automatic generation of a structured report that includes the annotation data and calculated quantitative and qualitative metrics presented in a graph, table, key images, and structured text report. AI Metrics AI METRICS, LLC
33 G01900 06 ThinkingNet THINKING SYSTEMS CORPORATION
34 G003DM01 1 3D printed patient specific replicas of patient anatomy 3D Anatomic Model RICOH USA, INC.
35 EZIEZIEHMVISIONV3D1 30236 Ziehm Vision2 Vario 3D ZIEHM IMAGING GMBH
36 EZIEZIEHMVISIONV1 30237 Ziehm Vision2 Vario ZIEHM IMAGING GMBH
37 EZIEZIEHMVISIONRFD3D1 302837 Ziehm Vision RFD 3D ZIEHM IMAGING GMBH
38 EZIEZIEHMVISIONRFD3D1 302837 Ziehm Vision RFD 3D ZIEHM IMAGING GMBH
39 EZIEZIEHMVISIONRFD1 302801 Ziehm Vision RFD ZIEHM IMAGING GMBH
40 EZIEZIEHMVISIONR1 302805 Ziehm Vision R ZIEHM IMAGING GMBH
41 EZIEZIEHMVISIONFDV3D1 30238 Ziehm Vision2 FD Vario 3D ZIEHM IMAGING GMBH
42 EZIEZIEHMVISIONFDV1 30239 Ziehm Vision2 FD Vario ZIEHM IMAGING GMBH
43 EZIEZIEHMVISIONFD165 302891; 302929 Ziehm Vision FD ZIEHM IMAGING GMBH
44 EZIEZIEHMVISIONFD1 30208 Ziehm Vision2 FD ZIEHM IMAGING GMBH
45 EZIEZIEHMVISION1 30355 Ziehm Vision2 ZIEHM IMAGING GMBH
46 EZIEZIEHMSOLOFD1 132874 Ziehm Solo FD ZIEHM IMAGING GMBH
47 EZIEZIEHMSOLO1 302711 Ziehm Solo ZIEHM IMAGING GMBH
48 EZIEZIEHM8000 308000 Ziehm 8000 ZIEHM IMAGING GMBH
49 EOLEOLEASPHEREV3P01 3.0 Olea Sphere V3.0 is an image processing software package to be used by trained p Olea Sphere V3.0 is an image processing software package to be used by trained professionals including but not limited to physicians and medical technicians. The software runs on a standard "off-the-shelf" workstation and can be used to perform image viewing, processing, image collage and analysis of medical images. Data and images are acquired through DICOM compliant imaging devices and modalities. OLEA SPHERE OLEA MEDICAL USA
50 EOLEOLEASPHEREV2P31 2.3 Olea Sphere V2.3 is an image processing software package to be used by trained p Olea Sphere V2.3 is an image processing software package to be used by trained professionals including but not limited to physicians and medical technicians. The software runs on a standard "off-the-shelf" workstation and can be used to perform image viewing, processing, image collage and analysis of medical images. Data and images are acquired through DICOM compliant imaging devices and modalities. OLEA SPHERE OLEA MEDICAL USA