No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 10705034157832 | 188319412 | 188319412 | MOUNTAINEER OCT SPINAL SYSTEM MINI POLYAXIAL BONE SCREW 3.5 x 4 x 12mm | NKG,MNI,KWP | Orthosis, cervical pedicle screw spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATI Orthosis, cervical pedicle screw spinal fixation,ORTHOSIS, SPINAL PEDICLE FIXATION,APPLIANCE, FIXATION, SPINAL INTERLAMINAL | 2 | MOUNTAINEER |
2 | 10705034157825 | 188319410 | 188319410 | MOUNTAINEER OCT SPINAL SYSTEM MINI POLYAXIAL BONE SCREW 3.5 x 4.0 x 10mm | NKG,KWP,MNI | Orthosis, cervical pedicle screw spinal fixation,APPLIANCE, FIXATION, SPINAL INT Orthosis, cervical pedicle screw spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | MOUNTAINEER |
3 | 10705034157818 | 188319408 | 188319408 | MOUNTAINEER OCT SPINAL SYSTEM MINI POLYAXIAL BONE SCREW 3.5 x 4.0 x 8mm | NKG,KWP,MNI | Orthosis, cervical pedicle screw spinal fixation,APPLIANCE, FIXATION, SPINAL INT Orthosis, cervical pedicle screw spinal fixation,APPLIANCE, FIXATION, SPINAL INTERLAMINAL,ORTHOSIS, SPINAL PEDICLE FIXATION | 2 | MOUNTAINEER |
4 | 10886705032228 | 242309 | 242309 | ENDOSCOPE TRAY | FSM | TRAY, SURGICAL, INSTRUMENT | 1 | NA |
5 | 10886705031962 | 242107 | 242107 | Endoscope, Mitek Lock 30 degree x 2.7 mm x 75 mm | EOB,HRX | Nasopharyngoscope (flexible or rigid),Arthroscope | 2 | NA |
6 | 10886705021901 | 215504 | 215504 | Hip Slotted Cannula Tray | FSM | TRAY, SURGICAL, INSTRUMENT | 1 | NA |
7 | 10886705032150 | 242277 | 242277 | C-Mount Endoscope, Mitek Lock 70 degree x 2.7 mm x 75 mm | HRX,EOB | Arthroscope,Nasopharyngoscope (flexible or rigid) | 2 | NA |
8 | 10886705032143 | 242276 | 242276 | C-Mount Endoscope, Mitek Lock 30 degree x 2.7 mm x 75 mm | HRX,EOB | Arthroscope,Nasopharyngoscope (flexible or rigid) | 2 | NA |
9 | 10886705032136 | 242275 | 242275 | C-Mount Endoscope, Mitek Lock 0 degree x 2.7 mm x 75 mm | HRX,EOB | Arthroscope,Nasopharyngoscope (flexible or rigid) | 2 | NA |
10 | 00878528001362 | CSP181800-30 | CSP18180030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 18mm x 30cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 18mm x 30cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
11 | 00878528001355 | CSP181700-30 | CSP18170030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 17mm x 30cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 17mm x 30cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
12 | 00878528001348 | CSP181600-30 | CSP18160030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 16mm x 27.9cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 16mm x 27.9cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
13 | 00878528001331 | CSP181500-30 | CSP18150030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 15mm x 26cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 15mm x 26cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
14 | 00878528001324 | CSP181400-30 | CSP18140030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 14mm x 24.3cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 14mm x 24.3cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
15 | 00878528001317 | CSP181300-30 | CSP18130030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 13mm x 22.6cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 13mm x 22.6cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
16 | 00878528001300 | CSP181200-30 | CSP18120030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 12mm x 20.7cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 12mm x 20.7cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
17 | 00878528001294 | CSP181100-30 | CSP18110030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 11mm x 18.9cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 11mm x 18.9cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
18 | 00878528001287 | CSP181000-30 | CSP18100030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 10mm x 17.1cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 10mm x 17.1cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
19 | 00878528001270 | CSP180900-30 | CSP18090030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 9mm x 15.3cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 9mm x 15.3cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
20 | 00878528001263 | CSP180800-30 | CSP18080030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 8mm x 13.6cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 8mm x 13.6cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
21 | 00878528001256 | CSP180700-30 | CSP18070030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 7mm x 14.3cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 7mm x 14.3cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
22 | 00878528001249 | CSP180600-30 | CSP18060030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 6mm x 12.2cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 6mm x 12.2cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
23 | 00878528001232 | CSP180500-30 | CSP18050030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 5mm x 10cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 5mm x 10cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
24 | 00878528001225 | CSP180400-30 | CSP18040030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 4mm x 7.9cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 4mm x 7.9cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
25 | 00878528001218 | CSP180300-30 | CSP18030030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 3mm x 5.8cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 3mm x 5.8cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
26 | 00878528001201 | CSP180200-30 | CSP18020030 | MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 2mm x 2.7cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 18 CERECYTE Coil 2mm x 2.7cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
27 | 00878528001102 | CSP101000-30 | CSP10100030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 10mm x 20.3cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 10mm x 20.3cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
28 | 00878528001096 | CSP100900-30 | CSP10090030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 9mm x 18.4cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 9mm x 18.4cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
29 | 00878528001089 | CSP100800-30 | CSP10080030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 8mm x 16.1cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 8mm x 16.1cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
30 | 00878528001072 | CSP100700-30 | CSP10070030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 7mm x 13.9cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 7mm x 13.9cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
31 | 00878528001065 | CSP100600-30 | CSP10060030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 6mm x 11.9cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 6mm x 11.9cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
32 | 00878528001058 | CSP100500-30 | CSP10050030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 5mm x 9.7cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 5mm x 9.7cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
33 | 00878528001041 | CSP100400-30 | CSP10040030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 4mm x 7.5cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 4mm x 7.5cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
34 | 00878528001034 | CSP100350-30 | CSP10035030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 3.5mm x 6.6cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 3.5mm x 6.6cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
35 | 00878528001027 | CSP100300-30 | CSP10030030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 3mm x 5.4cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 3mm x 5.4cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
36 | 00878528001010 | CSP100250-30 | CSP10025030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 2.5mm x 3.3cm 190cm Contents: MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 2.5mm x 3.3cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
37 | 00878528001003 | CSP100200-30 | CSP10020030 | MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 2mm x 2.5cm 190cm Contents: 1 MICRUSPHERE microcoil MICRUSPHERE 10 CERECYTE Coil 2mm x 2.5cm 190cm Contents: 1 Detachable Coil System | HCG | DEVICE, NEUROVASCULAR EMBOLIZATION | 2 | MICRUSPHERE CERECYTE |
38 | 00859030005260 | PRDSACD | PRDSACD | PulseRider Aneurysm Neck Reconstruction Device Connection Cable | NJE | Intracranial Neurovascular Stent | PulseRider Aneurysm Neck Reconstruction Device Connection Cable | |
39 | 10886705032204 | 242329 | 242329 | Pure Vue Software expansion | FCW,GCJ | Light source, fiberoptic, routine,Laparoscope, general & plastic surgery | 2 | Pure Vue |
40 | 20886705030559 | 223173 | 223173 | FREE NEEDLE LOOP REVERSE CUTTING NEEDLE WITH STAINLESS STEEL WIRE LOOP 36mm 1/2 FREE NEEDLE LOOP REVERSE CUTTING NEEDLE WITH STAINLESS STEEL WIRE LOOP 36mm 1/2 c REVERSE CUTTING N=1 OS-6 | GAB | NEEDLE, SUTURING, DISPOSABLE | NA | |
41 | 10886705031979 | 242109 | 242109 | Endoscope, Mitek Lock 70 degree x 2.7 mm x 75 mm | EOB,HRX | Nasopharyngoscope (flexible or rigid),Arthroscope | 2 | NA |
42 | 20886704078651 | 82-8859 | 828859 | CODMAN CERTAS X-Ray Overlay Tool | JXG | Shunt, central nervous system and components | CODMAN CERTAS | |
43 | 10886705032235 | 242313 | 242313 | LID FOR CAMERA AND ENDOSCOPE TRAY | FSM | TRAY, SURGICAL, INSTRUMENT | 1 | NA |
44 | 10886705032211 | 242307 | 242307 | CAMERA HEAD SYSTEM TRAY | FSM | TRAY, SURGICAL, INSTRUMENT | 1 | NA |
45 | 10886705032129 | 242274 | 242274 | C-Mount Endoscope, Mitek Lock 30 degree x 1.9 mm x 60 mm | HRX,EOB | Arthroscope,Nasopharyngoscope (flexible or rigid) | 2 | NA |
46 | 10886705032112 | 242273 | 242273 | C-Mount Endoscope, Mitek Lock 0 degree x 1.9 mm x 60 mm | HRX,EOB | Arthroscope,Nasopharyngoscope (flexible or rigid) | 2 | NA |
47 | 10886705032105 | 242272 | 242272 | C-Mount Endoscope, Mitek Lock 70 degree x 3.5 mm x 205 mm | EOB,HRX | Nasopharyngoscope (flexible or rigid),Arthroscope | 2 | NA |
48 | 10886705032099 | 242271 | 242271 | C-Mount Endoscope, Mitek Lock 30 degree x 3.5 mm x 205 mm | EOB,HRX | Nasopharyngoscope (flexible or rigid),Arthroscope | 2 | NA |
49 | 10886705032082 | 242269 | 242269 | 4K C-Mount Endoscope, Mitek Lock 70 degree x 4 mm x 167 mm | EOB,HRX | Nasopharyngoscope (flexible or rigid),Arthroscope | 2 | NA |
50 | 10886705032075 | 242268 | 242268 | 4K C-Mount Endoscope, Mitek Lock 30 degree x 4 mm x 167 mm | EOB,HRX | Nasopharyngoscope (flexible or rigid),Arthroscope | 2 | NA |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | M781DFH80115901 | DFH80-115/90 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
2 | M781DFH80115801 | DFH80-115/80 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
3 | M781DFH60115901 | DFH60-115/90 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
4 | M781DFH60115801 | DFH60-115/80 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
5 | M781DFH10135901 | DFH10-135/90 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
6 | M781DFH10115901 | DFH10-115/90 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
7 | M781DFH10115801 | DFH10-115/80 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
8 | M781DF80115801 | DF80-115/80 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
9 | M781DF60115801 | DF60-115/80 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
10 | M781DF45115801 | DF45-115/80 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
11 | M781DF10135901 | DF10-135/90 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
12 | M781DF10115801 | DF10-115/80 | The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and ou The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with hydrophilic coating. | TwinFlo™ Catheter | THERMOPEUTIX, INC. | |
13 | M7819680801 | 96-8080 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
14 | M7819660601 | 96-6060 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
15 | M7819645251 | 96-4525 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
16 | M7819610101 | 96-1010 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
17 | M7819445451 | 94-4545 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
18 | M7819280801 | 92-8080 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
19 | M7819260601 | 92-6060 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
20 | M7819260251 | 92-6025 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
21 | M7819245451 | 92-4545 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
22 | M7819245251 | 92-4525 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
23 | M7819210101 | 92-1010 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
24 | M7819180801 | 91-8080 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
25 | M7819180601 | 91-8060 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
26 | M7819180451 | 91-8045 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
27 | M7819180251 | 91-8025 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
28 | M7819160601 | 91-6060 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
29 | M7819160451 | 91-6045 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
30 | M7819160251 | 91-6025 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
31 | M7819145451 | 91-4545 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
32 | M7819145251 | 91-4525 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlu The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
33 | M7819110801 | 91-1080 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
34 | M7819110601 | 91-1060 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
35 | M7819110451 | 91-1045 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with heparin in the hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
36 | M78110480801 | 104-8080 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
37 | M78110460601 | 104-6060 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
38 | M78110445451 | 104-4545 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
39 | M78110080801 | 100-8080 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
40 | M78110060601 | 100-6060 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
41 | M78110045251 | 100-4525 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
42 | M78110010101 | 100-1010 | The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlus The TAPAS® Catheter consists of a two concentric tubular shafts (proximal occlusion balloon and distal occlusion balloon, POB and DOB, respectively) and is used to infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The proximal infusion lumen (Red) may be accessed using external devices connected to this lumen. There are three additional smaller lumens: one lumen is used for inflation of the balloon on the DOB; one lumen is used for inflation of the balloon on the POB; and one lumen permits pressure monitoring (Yellow) distal to the proximal occlusion balloon. The simultaneous inflation of the balloons may isolate a target region within a vessel and allow the infusion of a fluid agent into the vascular region of interest. The catheter is supplied with hydrophilic coating. | TAPAS® Catheter | THERMOPEUTIX, INC. | |
43 | 16286780610023 | E01P3 | E01P3 | The Syringe, 10 mL is a component of the COBRA-OS™ Kit and is used to inflate th The Syringe, 10 mL is a component of the COBRA-OS™ Kit and is used to inflate the COBRA-OS™ balloon.The COBRA-OS™ is intended for temporary occlusion of large vessels including patients requiring emergency control of hemorrhage. | Syringe, 10 mL | FRONT LINE MEDICAL TECHNOLOGIES INC. |
44 | 16286780610016 | F01P1 | F01P1 | The COBRA-OS™ is intended for temporary occlusion of large vessels including pat The COBRA-OS™ is intended for temporary occlusion of large vessels including patients requiring emergency control of hemorrhage. | COBRA-OS™ | FRONT LINE MEDICAL TECHNOLOGIES INC. |
45 | 16286780610009 | F01K1 | F01K1 | The COBRA-OS™ is intended for temporary occlusion of large vessels including pat The COBRA-OS™ is intended for temporary occlusion of large vessels including patients requiring emergency control of hemorrhage. | COBRA-OS™ | FRONT LINE MEDICAL TECHNOLOGIES INC. |
46 | 10887714025256 | 362 | RB402070 | A coaxial catheter recommended for temporary occlusion of the aorta. | REBOA Catheter | NUMED, INC. |
47 | 10887714025249 | 362 | RB402050 | A coaxial catheter recommended for temporary occlusion of the aorta. | REBOA Catheter | NUMED, INC. |
48 | 10887714025232 | 362 | RB402030 | A coaxial catheter recommended for temporary occlusion of the aorta. | REBOA Catheter | NUMED, INC. |
49 | 10887714025225 | 362 | RB401070 | A coaxial catheter recommended for temporary occlusion of the aorta. | REBOA Catheter | NUMED, INC. |
50 | 10887714025218 | 362 | RB401050 | A coaxial catheter recommended for temporary occlusion of the aorta. | REBOA Catheter | NUMED, INC. |