No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 00866479000114 | BM1412-50-F-1 | Beacon Tissue Marker/Beacon Tissue Marker (SE) is a sterile, single patient use, Beacon Tissue Marker/Beacon Tissue Marker (SE) is a sterile, single patient use, PEKK discrete marker that is visible on standard radiographs (x-ray, mammography) aswell as ultrasound, and Magnetic Resonance Imaging (MRI) at up to 3.0 Tesla field strength. Beacon Tissue Marker/Beacon Tissue Marker (SE) is placed into soft tissue during open, percutaneous, or endoscopic procedures to radiographically mark a surgical location.Beacon Tissue Marker/Beacon Tissue Marker (SE) is supplied pre-loaded in the delivery device.The Beacon Tissue Marker delivery device has a beveled 12cm/14G needle with 1cm depth marks and a plunger. The Beacon Tissue Marker (SE) delivery device has a radiused tip 12cm/14G cannula with 1cm depth marks anda plunger. | NEU | Marker, Radiographic, Implantable | 2 | BEACON | |
2 | 00866479000107 | BM1412-50-1 | Beacon Tissue Marker/Beacon Tissue Marker (SE) is a sterile, single patient use, Beacon Tissue Marker/Beacon Tissue Marker (SE) is a sterile, single patient use, PEKK discrete marker that is visible on standard radiographs (x-ray, mammography) aswell as ultrasound, and Magnetic Resonance Imaging (MRI) at up to 3.0 Tesla field strength. Beacon Tissue Marker/Beacon Tissue Marker (SE) is placed into soft tissue during open, percutaneous, or endoscopic procedures to radiographically mark a surgical location. Beacon Tissue Marker/Beacon Tissue Marker (SE) is supplied pre-loaded in the delivery device. The Beacon Tissue Marker delivery device has a beveled 12cm/14G needle with 1cm depth marks and a plunger. The Beacon Tissue Marker (SE) delivery device has a radiused tip 12cm/14G cannula with 1cm depth marks anda plunger. | NEU | Marker, Radiographic, Implantable | BEACON | ||
3 | 00866479000152 | CS-2001-CC-10 | The Cassi Rotational Core Biopsy System with Quadpoint Disposable isused to perf The Cassi Rotational Core Biopsy System with Quadpoint Disposable isused to perform biopsy pro-cedures on multiple patients. Up to 7 biopsycycles (1 mandatory pre-test and 6 biopsies) can be performed per patient.The Cassi system components and catalog numbers are:REF: CS2100-NT Cassi Rotational Core Biopsy Needle – 10 gauge10 – Sterile single-use biopsy needles and sample trays; comprisedof a 19 gauge x 2 cm length securing needle with 10 gauge cuttingcannula with trocarREF: CS2120-NT Cassi Rotational Core Biopsy Needle – 12 gauge10 – Sterile single-use biopsy needles and sample trays; comprised ofa 19 gauge x 2 cm length securing needle with a 12 gauge cutting cannulawith trocarREF: CS2001-CC-1010 – Non-sterile single-use CO2 (carbon dioxide) canisters with capsREF:CS2001-BH1 – Non-sterile limited reusable biopsy handle and 1 spare limited-use9 – volt alkaline battery | KNW | Instrument, Biopsy | 2 | Cassi | |
4 | 00866479000145 | CS2001-BH | The Cassi Rotational Core Biopsy System with Quadpoint Disposable isused to perf The Cassi Rotational Core Biopsy System with Quadpoint Disposable isused to perform biopsy pro-cedures on multiple patients. Up to 7 biopsycycles (1 mandatory pre-test and 6 biopsies) can be performed per patient.The Cassi system components and catalog numbers are:REF: CS2100-NT Cassi Rotational Core Biopsy Needle – 10 gauge10 – Sterile single-use biopsy needles and sample trays; comprisedof a 19 gauge x 2 cm length securing needle with 10 gauge cuttingcannula with trocarREF: CS2120-NT Cassi Rotational Core Biopsy Needle – 12 gauge10 – Sterile single-use biopsy needles and sample trays; comprised ofa 19 gauge x 2 cm length securing needle with a 12 gauge cutting cannulawith trocarREF: CS2001-CC-1010 – Non-sterile single-use CO2 (carbon dioxide) canisters with capsREF:CS2001-BH1 – Non-sterile limited reusable biopsy handle and 1 spare limited-use9 – volt alkaline battery | KNW | Instrument, Biopsy | 2 | Cassi | |
5 | 00866479000138 | CS2120-NT-1 | The Cassi Rotational Core Biopsy System with Quadpoint Disposable isused to perf The Cassi Rotational Core Biopsy System with Quadpoint Disposable isused to perform biopsy pro-cedures on multiple patients. Up to 7 biopsycycles (1 mandatory pre-test and 6 biopsies) can be performed per patient.The Cassi system components and catalog numbers are:REF: CS2100-NT Cassi Rotational Core Biopsy Needle – 10 gauge10 – Sterile single-use biopsy needles and sample trays; comprisedof a 19 gauge x 2 cm length securing needle with 10 gauge cuttingcannula with trocarREF: CS2120-NT Cassi Rotational Core Biopsy Needle – 12 gauge10 – Sterile single-use biopsy needles and sample trays; comprised ofa 19 gauge x 2 cm length securing needle with a 12 gauge cutting cannulawith trocarREF: CS2001-CC-1010 – Non-sterile single-use CO2 (carbon dioxide) canisters with capsREF:CS2001-BH1 – Non-sterile limited reusable biopsy handle and 1 spare limited-use9 – volt alkaline battery | KNW | Instrument, Biopsy | 2 | Cassi |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 04526737120034 | BIO22100 | 22G x 100mmwith suction syringe | BIOSUC-C7 | HAKKO CO.,LTD. | |
2 | 04526737120027 | BIO2250 | 22G x 50mmwith suction syringe | BIOSUC-C7 | HAKKO CO.,LTD. | |
3 | 04526737120010 | BIO20100 | 20G x 100mmwith suction syringe | BIOSUC-C7 | HAKKO CO.,LTD. | |
4 | 04526737120003 | BIO2050 | 20G x 50mmwith suction syringe | BIOSUC-C7 | HAKKO CO.,LTD. | |
5 | 04260632793282 | BOW-1066-13-0100 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
6 | 04260632793275 | BOW-1066-13-0062 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
7 | 04260632793268 | BOW-1066-11-0150 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
8 | 04260632793251 | BOW-1066-11-0125 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
9 | 04260632793244 | BOW-1066-11-0100 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
10 | 04260632793237 | BOW-1066-08-0150 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
11 | 04260632793220 | BOW-1066-08-0125 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
12 | 04260632793213 | BOW-1066-08-0100 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
13 | 04260632793183 | BOW-1076-15-0100 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
14 | 04260632793176 | BOW-1076-15-0050 | Bone marrow biopsy system | MÖLLER MEDICAL GMBH | ||
15 | 04260277178130 | COX-2020-18-0149 | Coaxial needle | MÖLLER MEDICAL GMBH | ||
16 | 04260277178123 | COX-2020-18-0109 | Coaxial needle | MÖLLER MEDICAL GMBH | ||
17 | 04260277178116 | COX-2020-18-0049 | Coaxial needle | MÖLLER MEDICAL GMBH | ||
18 | 04260277178093 | DNG-2020-18-0250 | Fullcore Biopsy Needle | MÖLLER MEDICAL GMBH | ||
19 | 04260277178079 | DNG-2020-16-0250 | Fullcore Biopsy Needle | MÖLLER MEDICAL GMBH | ||
20 | 04260277177942 | ABG-2020-16-0075 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
21 | 04260277177904 | COX-2020-16-0149 | Coaxial needle | MÖLLER MEDICAL GMBH | ||
22 | 04260277177898 | COX-2020-16-0109 | Coaxial needle | MÖLLER MEDICAL GMBH | ||
23 | 04260277177881 | COX-2020-16-0049 | Coaxial needle | MÖLLER MEDICAL GMBH | ||
24 | 04260277177621 | ABG-2040-20-0200 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
25 | 04260277177614 | ABG-2040-20-0150 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
26 | 04260277177607 | ABG-2040-20-0100 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
27 | 04260277177591 | ABG-2040-18-0250 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
28 | 04260277177584 | ABG-2040-18-0200 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
29 | 04260277177577 | ABG-2040-18-0150 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
30 | 04260277177560 | ABG-2040-18-0100 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
31 | 04260277177553 | ABG-2040-16-0200 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
32 | 04260277177546 | ABG-2040-16-0150 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
33 | 04260277177539 | ABG-2040-16-0100 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
34 | 04260277177522 | ABG-2040-14-0200 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
35 | 04260277177515 | ABG-2040-14-0150 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
36 | 04260277177508 | ABG-2040-14-0100 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
37 | 04260277177324 | ABG-2030-14-0200 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
38 | 04260277177317 | ABG-2030-14-0150 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
39 | 04260277177300 | ABG-2030-14-0100 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
40 | 04260277177294 | ABG-2030-16-0200 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
41 | 04260277177287 | ABG-2030-16-0150 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
42 | 04260277177270 | ABG-2030-16-0100 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
43 | 04260277177263 | ABG-2030-18-0250 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
44 | 04260277177256 | ABG-2030-18-0200 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
45 | 04260277177249 | ABG-2030-18-0150 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
46 | 04260277177232 | ABG-2030-18-0100 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
47 | 04260277177225 | ABG-2030-20-0200 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
48 | 04260277177218 | ABG-2030-20-0150 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
49 | 04260277177201 | ABG-2030-20-0100 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH | ||
50 | 04260277176990 | ABG-2020-20-0300 | Disposable Automatic Biopsy Gun | MÖLLER MEDICAL GMBH |