The TCDB40 Wafer Assembly consists of a copper wafer and plastic holder. The pla
The TCDB40 Wafer Assembly consists of a copper wafer and plastic holder. The plastic holder is color coded to assist the operator with proper placement/insertion. The wafer assembly is placed in the TCDB40 Sterile Tube Welding device prior to the weld process. The copper wafer is separated from the plastic holder during the welding process and after welding is completed both the plastic holder and the copper wafer are removed from the device and discarded. The wafers are single use only and cannot be reused. The TCDB40 Sterile Tube Welding device will not operate without a wafer assembly inserted and will not operate with a used a wafer. The TCDB40 wafer assemblies are packaged in 8 plastic trays. Each tray has 25 individual wafer assemblies. Each box referred to as a case has a total of 200 individual TCDB40 wafer assemblies.
The TCD B40 Wafer Assembly consists of a copper wafer and a plastic holder. The
The TCD B40 Wafer Assembly consists of a copper wafer and a plastic holder. The plastic holder is color coded to assist the operator with proper placement/insertion.The wafer assembly is placed in the device prior to the weld process. During the welding process the copper wafer is separated from the plastic holder, and after welding is completed, both the holder and wafer are removed from the device and discarded. The wafers are one-time use only and cannot be reused. The TCD B40 device will not operate without a wafer assembly inserted and will not operate with a used wafer. The TCD B40 wafer assemblies are packaged in boxes containing 240 wafer assemblies in each box referred to as a case.
The TCD B40 is a bench top, portable device intended for use by appropriately tr
The TCD B40 is a bench top, portable device intended for use by appropriately trained and qualified personnel in hospital/laboratory/clinical settings for the purpose of making sterile connections of 3.9 mm to 4.5 mm PVC tubing in blood processing applications.
The Genesis Rapid Weld STW is a medical device used in laboratories, designed fo
The Genesis Rapid Weld STW is a medical device used in laboratories, designed for the purpose of making sterile connections in PVC tubing in blood processing applications. The device enables fluid transfer while maintaining a closed system without the need for a consumable (disposable wafer).
The Blade Module consists of a stainless steel blade that cuts the PVC tube segm
The Blade Module consists of a stainless steel blade that cuts the PVC tube segments. The Blade Module is designed with a built in service meter to record the number of welds performed on the device. This feature monitors the usage endured by the Blade Module. The operator is notified when the Blade Module requires replacement. If the operator fails to respond to the warning message and replace the Blade Module the Genesis Rapid Weld STW will not operate once the Blade Module weld cycle limit is reached. Operation will resume once a replacement Blade Module is installed.
The Blade Module consists of a stainless steel blade that cuts the PVC tube segm
The Blade Module consists of a stainless steel blade that cuts the PVC tube segments. The Blade Module is designed with a built in service meter to record the number of welds performed on the device. This feature monitors the usage endured by the Blade Module. The operator is notified when the Blade Module requires replacement. If the operator fails to respond to the warning message and replace the Blade Module the Genesis Rapid Weld STW will not operate once the Blade Module weld cycle limit is reached. Operation will resume once a replacement Blade Module is installed.
The Blade Module consists of a stainless steel blade that cuts the PVC tube segm
The Blade Module consists of a stainless steel blade that cuts the PVC tube segments. The Blade Module is designed with a built in service meter to record the number of welds performed on the device. This feature monitors the usage endured by the Blade Module. The operator is notified when the Blade Module requires replacement. If the operator fails to respond to the warning message and replace the Blade Module the Genesis RapidWeld STW, Model GRW-430 will not operate once the Blade Module weld cycle limit is reached. Operation will resume once a replacement Blade Module is installed.
The CompoDock is used for the production of special cellular blood components, e
The CompoDock is used for the production of special cellular blood components, e.g. in blood banks where tube connections are needed that provide protection against microbial contamination.The CompoDock is a high-frequency connection device that permits sterile connection of medical PVC tubes to one another.Here, sterile connection is achieved when germs from the environment are prevented from being carried into the closed systems. The closed system is maintained after the docking process.
The Genesis RapidWeld II STW, model GRW-430-02, is a medical device used in labo
The Genesis RapidWeld II STW, model GRW-430-02, is a medical device used in laboratories, designed for the purpose of making sterile connections in PVC tubing in blood processing applications. The device enables fluid transfer while maintaining a closed system without the need for a consumable (disposable wafer).
The TCD B40 is a bench top, portable device intended for use by appropriately tr
The TCD B40 is a bench top, portable device intended for use by appropriately trained and qualified personnel in hospital/laboratory/clinical settings for the purpose of making sterile connections of 3.9 mm to 4.5 mm PVC tubing in blood processing applications.
The Genesis Rapid Weld STW is a medical device used in laboratories, designed fo
The Genesis Rapid Weld STW is a medical device used in laboratories, designed for the purpose of making sterile connections in PVC tubing in blood processing applications. The device enables fluid transfer while maintaining a closed system without the need for a consumable (disposable wafer).