Basic Chlorine Sentinel - The Nelson Sentinel Series Basic Chlorine - Nelson Environmental Technologies Inc

Duns Number:835316464

Device Description: The Nelson Sentinel Series Basic Chlorine Sentinel is a complete system that attaches to t The Nelson Sentinel Series Basic Chlorine Sentinel is a complete system that attaches to the drain of a hemodialysis water treatment system sample port. The Basic Chlorine Sentinel detects dissolved chlorine by an auxiliary meter detection technology, self-monitors for maintenance-required conditions, loss of electrical power, as well as two other system conditions such as flooding and the status of RO shutdown alarm. The device chlorine monitoring probe is preferably placed after the second carbon filter, before the RO machine or at the beginning of the patient water treatment loop.The device has three components – a lockable master control enclosure, a lockable probe/tester enclosure, and the remote module installed in the patient area.A chlorine concentration equal to or above the set-point (default: 0.10mg/L) will activate the buzzers and the red CHLORINE alarm indicators for as long as the condition exists. The buzzers can only be muted for 3 minutes (then automatically reset) for as long as the condition exists. The yellow AUTO-TEST OK/CL DETECTED indication will latch. The AUTO-TEST/CL DETECTED indication can be deactivated after the event by pressing the blue RESET PUSHBUTTON on the front cover of the controller.A probe failure or the activation of one of the auxiliary input relays will activate the yellow MAINTENANCE needed indicators as well as the Buzzers which will remain activated as long as the condition exists. However, the buzzers can be muted by the key mute switch while the maintenance issue is being resolved.

Want to know more about this Product? Request more information now!


More Product Details

Catalog Number

-

Brand Name

Basic Chlorine Sentinel

Version/Model Number

NSS-BCS-001

Device Commercial Distribution Status

In Commercial Distribution

Commercial Distribution End Date

-

Issuing Agency

In GS1

Product Characteristics

MRI safety Status

Labeling does not contain MRI Safety Information

Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)

-

Device labeled as "Not made with natural rubber latex"

-

For Single-Use

-

Prescription Use (Rx)

-

Over the Counter (OTC)

-

Kit

-

Combination Product

-

Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)

-

FDA Premarket Submission

-

Product Code Details

Product Code

FIP

Product Code Name

Subsystem, Water Purification

Device Record Status

Public Device Record Key

13131fdc-e803-44d2-acab-35465555da12

Public Version Date

July 14, 2022

Public Version Number

1

DI Record Publish Date

July 06, 2022

Additional Identifiers

Package DI Number

None

Quantity per Package

-

Contains DI Package

-

Package Discontinue Date

-

Package Status

-

Package Type

-

"NELSON ENVIRONMENTAL TECHNOLOGIES INC" Characteristics
Device Class Device Class Description No of Devices
2 A medical device with a moderate to high risk that requires special controls. 1