No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00857595006005 TVC-MC8-B1 TVC-MC8-B1 Individual Sterile Barrier for TVC-MC8 or TVC-MC9 System Controller IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation TVC Controller Sterile Barrier
2 00857595006425 TVC-MC9 TVC-MC9 TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32).Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
3 00857595006418 TVC-MC8 TVC-MC8 TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
4 00857595006401 TVC-MC8 TVC-MC8 TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging. Non-RoHsIndications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
5 00857595006234 TVC-C195-42 TVC-C195-42 The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, dispo The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, disposable coronary catheter and accessory kit designed for use only with the Makoto Intravascular Imaging System™ (TVC-MC10 and TVC-MC10i). The dual-modality intravascular imaging catheter combines 50 MHz Extended Bandwidth IVUS transducer and laser-based near infrared spectroscopy (NIRS) for simultaneous acquisition of vessel structure and plaque composition data— a single catheter, a single pullback, two sets of data. The Dualpro™ IVUS+NIRS Imaging Catheter features a durable hydrophilic coating for improved deliverability.Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 Dualpro™ IVUS+NIRS Imaging Catheter Kit
6 04543660023515 GLGMF-YOK0A This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.The OKAY® II Y-Connector Set reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y-connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
7 04543660023508 GLGMN-YOK0A This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
8 04543660023492 GLGMF-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
9 04543660023485 GLGMN-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
10 04543660022341 YOK0B OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector
11 00857595006210 TVC-C195-22 TVC-C195-22 Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC-C195-22) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight™
12 00857595006203 TVC-C195-20 TVC-C195-20 Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single us Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer.Indications for Use: 1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OBJ,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Ultrasound, Intravascular,Cat System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight™
13 04543660022662 GM-30NL GM-30NL 30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubi 30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubing and 3 position stopcock for balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
14 04543660022655 GM-30NF GM-30NF 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
15 04543660022648 GM-30N GM-30N 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 3 position stopcock for angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
16 04543660022334 YOK0A OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector Set
17 04543660022358 YOK0E OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector Set with Extension Tube
18 00857595006227 TVC-C195-32 TVC-C195-32 Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Cathet Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Catheter Kit (TVC-C195-32) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™(TVC-MC9, TVC-MC9i, and properly configured TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and 50 MHz Extended Bandwidth ultrasonics for simultaneous acquisition of vessel structure and plaque composition— a single catheter, a single pullback, two sets of data. The Insight XB catheter features a 50MHz Extended Bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight XB™
19 00857595006432 TVC-MC10 TVC-MC10 The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravasc The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated Extended Bandwidth IVUS imaging and NIRS (near infrared spectroscopy) technologies to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50 MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42). Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 Makoto Intravascular Imaging System™
Other products with the same Product Codes "IYO, OGZ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00382830041751 482-651600 Vista Software CD Natus NATUS NEUROLOGY INCORPORATED
2 00382830038201 222-515000 PROBE/ULTRASOUND USB MV 12MHZ Natus NATUS NEUROLOGY INCORPORATED
3 00382830038195 222-515100 PROBE/ULTRASOUND USB VC 7.5MHZ Natus NATUS NEUROLOGY INCORPORATED
4 00380657501236 8065750123 Biometry Probe 10MHZ Alcon ALCON LABORATORIES, INC.
5 00380657410774 8065741077 Straight Pacymetry Probe, 20MHZ Alcon ALCON LABORATORIES, INC.
6 00380657410736 8065741073 Biometry Probe, With Applicator, 10MHZ Alcon ALCON LABORATORIES, INC.
7 00380656786108 8065-6786-10 20 GA StraightLaser Probe Alcon ALCON LABORATORIES, INC.
8 00195278530981 iq v203 to v206 UPG Vivid iq v203 to v206 upgrade kit Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
9 00195278516541 R4 UPG Venue Go R4 MD either eDelivery or physical Venue Go GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
10 00195278516534 R4 UPG Venue R4 MD either eDelivery or physical Venue GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
11 00195278516510 R4 Venue Go R4 Final Assembly Venue Go GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
12 00195278516497 R4 Venue Fit R4 Final Assembly Venue Fit GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
13 00195278516480 R4 Venue R4 final Assembly Venue GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
14 00195278516343 E v203 v204 to v206 UPG Vivid E95, E90, E80 v203 v204 to v206 UPG Vivid GE VINGMED ULTRASOUND AS
15 00195278516312 S v203 v204 v205 to v206 UPG Vivid S70N S60N v203 v204 v205 to v206 Upg kit Vivid GE VINGMED ULTRASOUND AS
16 00195278513014 R4 UPG Venue Fit R4 MD either eDelivery or physical Venue Fit GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
17 00195278505354 E90 v206 Vivid E90 v206 Vivid GE VINGMED ULTRASOUND AS
18 00195278505347 E80 v206 Vivid E80 v206 Vivid GE VINGMED ULTRASOUND AS
19 00195278505330 E95 v206 Vivid E95 v206 Vivid GE VINGMED ULTRASOUND AS
20 00195278505316 S60N v206 Vivid S60N v206 NOR Vivid GE VINGMED ULTRASOUND AS
21 00195278505255 S70N v206 Vivid S70N v206 NOR Vivid GE VINGMED ULTRASOUND AS
22 00195278505187 S60N v206CH Vivid S60N v206 China Vivid GE VINGMED ULTRASOUND AS
23 00195278505170 S70N v206CH Vivid S70N v206 China Vivid GE VINGMED ULTRASOUND AS
24 00195278488527 iq v204 to v206 UPG SW only Vivid iq V204 to V206 SW only upgrade kit Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
25 00195278487414 E10s R2 to R3 UPG LOGIQ E10s R2 to R3 UPG LOGIQ GE ULTRASOUND KOREA LTD.
26 00195278473103 P8 BT22 VOLUSON-P8-BT22 Voluson P8 BT22 Voluson GE ULTRASOUND KOREA LTD.
27 00195278473097 P6 BT22 VOLUSON-P6-BT22 Voluson P6 BT22 Voluson GE ULTRASOUND KOREA LTD.
28 00195278473080 S6 BT22 VOLUSON-S6-BT22 Voluson S6 BT22 Voluson GE ULTRASOUND KOREA LTD.
29 00195278473073 S8 BT22 VOLUSON-S8-BT22 Voluson S8 BT22 Voluson GE ULTRASOUND KOREA LTD.
30 00195278473066 S8t BT22 VOLUSON-S8t-BT22 Voluson S8t BT22 Voluson GE ULTRASOUND KOREA LTD.
31 00195278473059 S10 T22 VOLUSON-S10-BT22 Voluson S10 BT22 Voluson GE ULTRASOUND KOREA LTD.
32 00195278473042 S10 Expert BT22 VOLUSON-S10Expert-BT22 Voluson S10 Expert BT22 Voluson GE ULTRASOUND KOREA LTD.
33 00195278473028 Signature to BT22 UPG Voluson-Signature-to-BT22-UPG Voluson Signature to BT22 UPG Voluson GE ULTRASOUND KOREA LTD.
34 00195278473011 Performance to BT22 UPG Voluson-Performance-to-BT22-UPG Voluson Performance to BT22 UPG Voluson GE ULTRASOUND KOREA LTD.
35 00195278464675 P9 R4 to R4.5 SW Conversion LP9 R4 to R4.5 SW Conversion LOGIQ GE ULTRASOUND KOREA LTD.
36 00195278464668 P10 R4.5 HD LOGIQ P10 R4.5 HD LOGIQ GE ULTRASOUND KOREA LTD.
37 00195278464651 P9 R4 to R4.5 SW Conversion LP8 R4 to R4.5 SW Conversion LOGIQ GE ULTRASOUND KOREA LTD.
38 00195278464644 P10 R4.5 LOGIQ P10 R4.5 LOGIQ GE ULTRASOUND KOREA LTD.
39 00195278464637 P9 R4.5 LOGIQ P9 R4.5 LOGIQ GE ULTRASOUND KOREA LTD.
40 00195278464620 P10 R4 to R4.5 SW Conversion LP10 R4 to R4.5 SW Conversion LOGIQ GE ULTRASOUND KOREA LTD.
41 00195278464613 P8 R4.5 LOGIQ P8 R4.5 LOGIQ GE ULTRASOUND KOREA LTD.
42 00195278460677 iq v204 to v206 UPG Vivid iq v204 to v206 upgrade kit Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
43 00195278460639 T8 T9 v204 v205 to v206 UPG SW only Vivid T8 T9 v204 v205 to v206 upgrade kit SW only Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
44 00195278460622 T8 T9 v204 v205 to v206 UPG Vivid T8 T9 v204 v205 to v206 upgrade kit Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
45 00195278435743 E v204 4D ICE UPG Vivid E v204 4D ICE UPG Vivid GE VINGMED ULTRASOUND AS
46 00195278422286 T8 v206 T8 v206 console Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
47 00195278422279 T9 v206 T9 v206 console Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
48 00195278421388 iq v206 Vivid iq R6 basic console Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
49 00195278410245 E10s R3 OLED LOGIQ E10s R3 OLED LOGIQ GE ULTRASOUND KOREA LTD.
50 00195278410221 E10s R3 LOGIQ E10s R3 LOGIQ GE ULTRASOUND KOREA LTD.