Other products from "INFRAREDX, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00857595006425 TVC-MC9 TVC-MC9 TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC9) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32).Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
2 00857595006418 TVC-MC8 TVC-MC8 TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
3 00857595006401 TVC-MC8 TVC-MC8 TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravas TVC Imaging System™The TVC Imaging System™ (TVC-MC8) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and enhanced IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 40MHz rotational IVUS imaging from a single catheter. The system is compatible with the TVC Insight™ Catheter Kit (TVC-C195-20) and TVC Insight Hydrophilic Catheter Kit (TVC-C195-22). The system can be configured for Extended Bandwidth™ making the system compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32) that provides NIRS and 50MHz rotational IVUS imaging. Non-RoHsIndications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Imaging System™
4 00857595006234 TVC-C195-42 TVC-C195-42 The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, dispo The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, disposable coronary catheter and accessory kit designed for use only with the Makoto Intravascular Imaging System™ (TVC-MC10 and TVC-MC10i). The dual-modality intravascular imaging catheter combines 50 MHz Extended Bandwidth IVUS transducer and laser-based near infrared spectroscopy (NIRS) for simultaneous acquisition of vessel structure and plaque composition data— a single catheter, a single pullback, two sets of data. The Dualpro™ IVUS+NIRS Imaging Catheter features a durable hydrophilic coating for improved deliverability.Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 Dualpro™ IVUS+NIRS Imaging Catheter Kit
5 04543660023515 GLGMF-YOK0A This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.The OKAY® II Y-Connector Set reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y-connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
6 04543660023508 GLGMN-YOK0A This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer. (YOK0A)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
7 04543660023492 GLGMF-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation. (GM-30NF)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
8 04543660023485 GLGMN-YOK0E This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with This angioplasty convenience kit contains one(1) sterile pouch with OKAY-II with kit and extension tube and one(1) sterile pouch with a GM-30 Inflation Device.OKAY® II Y-Connector Set with Extension Tube reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube. (YOK0E)The GM-30 30atm-25cc inflation device features standard length, 31 cm, high pressure tubing and 3 position stopcock for single angioplasty balloon inflation and deflation. (GM-30N)Indications for Use:1. The Y-connector is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure.2. The inflation device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM,DTL Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiop Syringe, Balloon Inflation, Exempt,Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass 2 GM-30 Accessory Kit
9 04543660022341 YOK0B OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector
10 00857595006210 TVC-C195-22 TVC-C195-22 Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC Insight Hydrophilic Catheter™ Kit The TVC Insight Hydrophilic Catheter™ Kit (TVC-C195-22) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. OBJ,OGZ Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight™
11 00857595006203 TVC-C195-20 TVC-C195-20 Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single us Insight Catheter™ Kit The TVC Insight Catheter™ Kit (TVC-C195-20) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™ (TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and high fidelity 40 MHz ultrasonics for simultaneous acquisition of vessel structure and plaque composition—a single catheter, a single pullback, two sets of data. The catheter features a 40MHz wide bandwidth IVUS transducer.Indications for Use: 1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OBJ,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Ultrasound, Intravascular,Cat System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Ultrasound, Intravascular,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight™
12 04543660022662 GM-30NL GM-30NL 30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubi 30atm-25cc Inflation Device. Features extended length, 76 cm, high pressure tubing and 3 position stopcock for balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
13 04543660022655 GM-30NF GM-30NF 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 4 position stopcock for single or dual angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
14 04543660022648 GM-30N GM-30N 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubi 30atm-25cc Inflation Device. Features standard length, 31 cm, high pressure tubing and 3 position stopcock for angioplasty balloon inflation and deflation.Indications for Use:1. This device is recommended for use with balloon dilation catheters to create and monitor pressure in the balloon, and to deflate the balloon. PTM Syringe, Balloon Inflation, Exempt 2 GM-30 Inflation Device
15 04543660022334 YOK0A OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, and introducer.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector Set
16 04543660022358 YOK0E OKAY II reduces blood loss during procedures through the use of a hemostatic val OKAY II reduces blood loss during procedures through the use of a hemostatic valve not featured on conventional Y connectors. Its large 3.33mm (10F) inner diameter facilitates a variety of PCI devices and techniques, and a new feature has been added that allows the one-touch style hemostatic valve to be locked in the open position. Includes Y-connector, torque device, introducer, and extension tube.Indications for Use:1. This product is designed to work in conjunction with guiding catheters, etc. to reduce blood loss while assisting in manipulation of catheters, etc., injection of contrast solution from a side port, injection of medicine or saline solution, and measurement of blood pressure. DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass OKAY® II Y-Connector Set with Extension Tube
17 00857595006227 TVC-C195-32 TVC-C195-32 Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Cathet Insight XB™ Catheter KitThe TVC Insight XB™ Extended Bandwidth™ NIRS-IVUS Catheter Kit (TVC-C195-32) is a single use, disposable coronary catheter and accessory kit designed for use only with the TVC Imaging System™(TVC-MC9, TVC-MC9i, and properly configured TVC-MC8). The dual-modality intravascular imaging catheter combines laser-based near infrared spectroscopy (NIRS) and 50 MHz Extended Bandwidth ultrasonics for simultaneous acquisition of vessel structure and plaque composition— a single catheter, a single pullback, two sets of data. The Insight XB catheter features a 50MHz Extended Bandwidth IVUS transducer and durable hydrophilic coating for improved delivery.Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation TVC Insight XB™
18 00857595006623 TVC-MC9i TVC-MC9i TThe TVC Integrated Imaging System™ (TVC-MC9i) is a dual-modality intravascular TThe TVC Integrated Imaging System™ (TVC-MC9i) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated NIRS (near infrared spectroscopy) and Extended Bandwidth™ IVUS imaging technology to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50MHz Extended Bandwidth rotational IVUS imaging from a single catheter. This model of TVC Imaging System is designed to be installed in the catheterization laboratory and minimize usage of space. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the TVC Insight XB™ Extended Bandwidth NIRS-IVUS Catheter Kit (TVC-C195-32). Indications for Use:1. The TVC Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 TVC Integrated Imaging System™
19 00857595006432 TVC-MC10 TVC-MC10 The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravasc The Makoto Intravascular Imaging System™ (TVC-MC10) is a dual-modality intravascular imaging system that enables structural and chemical assessment of coronary arteries and plaques by using integrated Extended Bandwidth IVUS imaging and NIRS (near infrared spectroscopy) technologies to identify lipid-core plaques (LCP) of interest. The system utilizes proprietary NIRS analysis and 50 MHz Extended Bandwidth rotational IVUS imaging from a single catheter. The system features a touch screen control interface and a workflow that fits the complex catheterization laboratory environment. The system is compatible with the Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42). Indications for Use:1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures. IYO,OGZ System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphol System, Imaging, Pulsed Echo, Ultrasonic,Catheter, Intravascular, Plaque Morphology Evaluation 2 Makoto Intravascular Imaging System™
Other products with the same Product Codes "IYO, OGZ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00628055603108 SA-10-0029 Imaging catheter accessories Novasight Hybrid™ Catheter PIM Bag CONAVI MEDICAL INC
2 00628055603085 TA-07-0001 Imaging System Novasight Hybrid™ PIM CONAVI MEDICAL INC
3 00628055603078 TA-03-0005 Imaging System Novasight Hybrid™ Hummingbird Console CONAVI MEDICAL INC
4 00628055603061 SA-10-0022 Imaging catheter accessories Novasight Hybrid™ Catheter Accessories Package CONAVI MEDICAL INC
5 00628055603054 TA-06-0001 Imaging catheter Novasight Hybrid™ Catheter CONAVI MEDICAL INC
6 00628055481027 1.0 EV-SYS-120 The ExactVu high resolution micro-ultrasound system is intended for use by quali The ExactVu high resolution micro-ultrasound system is intended for use by qualified medical professionals for diagnostic ultrasound imaging, data processing and guidance of puncture and biopsy. The ExactVu System is comprised of transducers responsible for ultrasound signal generation and recording, a needle guide and a main unit that controls the transducers, processes the acoustic data, and processes and displays images. ExactVu High Resolution Micro-Ultrasound System EXACT IMAGING INC
7 00628055481010 1.0 EV-SYS-220 The ExactVu high resolution micro-ultrasound system is intended for use by quali The ExactVu high resolution micro-ultrasound system is intended for use by qualified medical professionals for diagnostic ultrasound imaging, data processing and guidance of puncture and biopsy. The ExactVu System is comprised of transducers responsible for ultrasound signal generation and recording, a needle guide and a main unit that controls the transducers, processes the acoustic data, and processes and displays images. ExactVu High Resolution Micro-Ultrasound System EXACT IMAGING INC
8 00627825005562 PRB266 NuWav LABORIE MEDICAL TECHNOLOGIES CANADA ULC
9 00627825005555 PRB265 NuWav LABORIE MEDICAL TECHNOLOGIES CANADA ULC
10 00627825005548 PRB260 NuWav LABORIE MEDICAL TECHNOLOGIES CANADA ULC
11 00627825005531 PRB250 NuWav LABORIE MEDICAL TECHNOLOGIES CANADA ULC
12 00627825005524 PRB240 NuWav LABORIE MEDICAL TECHNOLOGIES CANADA ULC
13 00627825005517 PRB262 NuWav LABORIE MEDICAL TECHNOLOGIES CANADA ULC
14 00618125188635 33442 Probe Covers Clear Polyethylene Sterile 9in x 96in x 1 in, 100 per Case Abbott Medical TIDI PRODUCTS, LLC
15 00618125175680 MI-100MILCDN Medi-Inn Probe Covers Clear Polyethylene Sterile 6.5in x 54in x .002in 100 per Case Medi-INN TIDI PRODUCTS, LLC
16 00618125143238 MICK-PC748BE Medi-Inn Ultrasound Probe Covers Clear Polyethylene Sterile 7in x 48in 50 per Case Medi-Inn TIDI PRODUCTS, LLC
17 00618125143221 MICK-PC748 Medi-Inn Ultrasound Probe Covers Clear Polyethylene Sterile 7in x 48in 100 per Case Medi-Inn TIDI PRODUCTS, LLC
18 00618125143207 MICK-P748 Medi-Inn Ultrasound Probe Covers Clear Polyethylene Sterile 7in x 48in 100 per Case Medi-Inn TIDI PRODUCTS, LLC
19 00618125143191 MICK-P732 Medi-Inn Ultrasound Probe Covers Clear Polyethylene Sterile 7in x 32in 100 per Case Medi-Inn TIDI PRODUCTS, LLC
20 00618125143184 MICK-P714 Medi-Inn Ultrasound Probe Covers Clear Polyethylene Sterile 7in x 14in 100 per Case Medi-Inn TIDI PRODUCTS, LLC
21 00618125143177 MICK-P696 COVER, PROBE, PE, 6.00 X 96.00 Medi-Inn TIDI PRODUCTS, LLC
22 00618125143153 MICK-P432 Medi-Inn Ultrasound Probe Covers Clear Polyethylene Sterile 4in x 32in 100 per Case Medi-Inn TIDI PRODUCTS, LLC
23 00618125143146 MICK-P424 Medi-Inn Ultrasound Probe Covers Clear Polyethylene Sterile 4in x 24in 100 per Case Medi-Inn TIDI PRODUCTS, LLC
24 00618125143122 MICK-P416 COVER, PROBE, PE, 4.00 X 16.00 Medi-Inn TIDI PRODUCTS, LLC
25 00382830041751 482-651600 Vista Software CD Natus NATUS NEUROLOGY INCORPORATED
26 00382830038201 222-515000 PROBE/ULTRASOUND USB MV 12MHZ Natus NATUS NEUROLOGY INCORPORATED
27 00382830038195 222-515100 PROBE/ULTRASOUND USB VC 7.5MHZ Natus NATUS NEUROLOGY INCORPORATED
28 00380657501236 8065750123 Biometry Probe 10MHZ Alcon ALCON LABORATORIES, INC.
29 00380657410774 8065741077 Straight Pacymetry Probe, 20MHZ Alcon ALCON LABORATORIES, INC.
30 00380657410736 8065741073 Biometry Probe, With Applicator, 10MHZ Alcon ALCON LABORATORIES, INC.
31 00380656786108 8065-6786-10 20 GA StraightLaser Probe Alcon ALCON LABORATORIES, INC.
32 00195278530981 iq v203 to v206 UPG Vivid iq v203 to v206 upgrade kit Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
33 00195278516541 R4 UPG Venue Go R4 MD either eDelivery or physical Venue Go GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
34 00195278516534 R4 UPG Venue R4 MD either eDelivery or physical Venue GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
35 00195278516510 R4 Venue Go R4 Final Assembly Venue Go GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
36 00195278516497 R4 Venue Fit R4 Final Assembly Venue Fit GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
37 00195278516480 R4 Venue R4 final Assembly Venue GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
38 00195278516343 E v203 v204 to v206 UPG Vivid E95, E90, E80 v203 v204 to v206 UPG Vivid GE VINGMED ULTRASOUND AS
39 00195278516312 S v203 v204 v205 to v206 UPG Vivid S70N S60N v203 v204 v205 to v206 Upg kit Vivid GE VINGMED ULTRASOUND AS
40 00195278513014 R4 UPG Venue Fit R4 MD either eDelivery or physical Venue Fit GE MEDICAL SYSTEMS, ULTRASOUND & PRIMARY CARE DIAGNOSTICS, LLC
41 00195278505354 E90 v206 Vivid E90 v206 Vivid GE VINGMED ULTRASOUND AS
42 00195278505347 E80 v206 Vivid E80 v206 Vivid GE VINGMED ULTRASOUND AS
43 00195278505330 E95 v206 Vivid E95 v206 Vivid GE VINGMED ULTRASOUND AS
44 00195278505316 S60N v206 Vivid S60N v206 NOR Vivid GE VINGMED ULTRASOUND AS
45 00195278505255 S70N v206 Vivid S70N v206 NOR Vivid GE VINGMED ULTRASOUND AS
46 00195278505187 S60N v206CH Vivid S60N v206 China Vivid GE VINGMED ULTRASOUND AS
47 00195278505170 S70N v206CH Vivid S70N v206 China Vivid GE VINGMED ULTRASOUND AS
48 00195278488527 iq v204 to v206 UPG SW only Vivid iq V204 to V206 SW only upgrade kit Vivid GE MEDICAL SYSTEMS (CHINA) CO.,LTD.
49 00195278487414 E10s R2 to R3 UPG LOGIQ E10s R2 to R3 UPG LOGIQ GE ULTRASOUND KOREA LTD.
50 00195278473103 P8 BT22 VOLUSON-P8-BT22 Voluson P8 BT22 Voluson GE ULTRASOUND KOREA LTD.