Other products from "NEOCOIL, LLC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00856181003657 65 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 General Purpose Support strap
2 00856181003961 96 NC143005 The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam. MOS Coil, Magnetic Resonance, Specialty 2 16ch Shoulder Coil, Replacement Pad Kit (FRU)
3 00856181003954 95 NC143003 The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam. MOS Coil, Magnetic Resonance, Specialty 2 1.5T 16ch Shoulder Coil (FRU)
4 00856181003930 93 NC143001 The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam. MOS Coil, Magnetic Resonance, Specialty 2 1.5T 16ch Shoulder Coil (System)
5 00856181003749 74 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coi MOS Coil, Magnetic Resonance, Specialty 2 Pediatric SPEEDER Stabilizer Kit
6 00856181003732 73 The NeoCoil Patient Communication and Entertainment (PCE) System is intended to The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals. LNH System, Nuclear Magnetic Resonance Imaging 2 Siemens audio module
7 00856181003602 60 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 Flex Coils Knee Stabilizer
8 00856181003527 52 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 wrist pad
9 00856181003268 26 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 Flex Coils Pediatric Stabilizer
10 00856181003244 24 The NeoCoil 3T l6ch Flex SPEEDER Coils are a receive-only phased array coil syst The NeoCoil 3T l6ch Flex SPEEDER Coils are a receive-only phased array coil system designed to provide high resolution imaging for the upper and lower extremities, chest, abdomen, pelvis. head, neck, and spine. The system is compatible with 20, 3D, parallel and isotropic imaging, as well as, coil signal intensity correction. MOS Coil, Magnetic Resonance, Specialty 2 3T 16ch Flex SPEEDER Large
11 00856181003145 14 MOS Coil, Magnetic Resonance, Specialty 2 3.0T GEM Flex Interface, P-Connector
12 00856181003114 11 MOS Coil, Magnetic Resonance, Specialty 2 3.0T GEM Flex Coil 16-S Array
13 00856181003107 10 The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for i The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. The NecCoil 1 .5T GEM Flex Coil is tuned to receive RF frequency corresponding to the proton precession in a 1.5 tesla magnetic field, which is governed by the Larmor equation. MOS Coil, Magnetic Resonance, Specialty 2 1.5T GEM Flex Interface, HD-Connector
14 00856181003046 04 The NeoCoil 1 ST 8-Channel Shoulder Array Coil is a multi-element phased array r The NeoCoil 1 ST 8-Channel Shoulder Array Coil is a multi-element phased array receive only coil used for obtaining diagnostic images of the shoulder in Magnetic Resonance Imaging Systems. Compared to predicate devices, the submitted device offers greater SNR due to its unique eight channel layout and a larger field-of-view due to the antenna layout. MOS Coil, Magnetic Resonance, Specialty 2 1.5T 8ch Shoulder Coil
15 00856181003633 63 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 Preamp Box Foam Sleeve
16 00856181003893 89 The NeoCoil 1.5T 16ch Breast Coil is a phased array coil for imaging structures The NeoCoil 1.5T 16ch Breast Coil is a phased array coil for imaging structures of the breast, axilla and chest wall. The 1.5T 16ch Breast Coil is a three part receive-only coil designed to provide high resolution imaging. The 1.5T 16ch Breast Coil includes a coil support structure, patient support structure, biopsy components and comfort pads. MOS Coil, Magnetic Resonance, Specialty 2 1.5T 16Ch Breast Coil
17 00856181003794 79 The NeoCoil Wireless Audio System is intended to provide entertainment and facil The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure. LNH System, Nuclear Magnetic Resonance Imaging 2 Router Assembly
18 00856181003763 76 The NeoCoil Wireless Audio System is intended to provide entertainment and facil The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure. LNH System, Nuclear Magnetic Resonance Imaging 2 Sentinel P1 Audio Interface Module
19 00856181003558 55 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil 1 ST 8-Channel Shoulder Array Coil. MOS Coil, Magnetic Resonance, Specialty 2 Shoulder Coil Strap assembly
20 00856181003510 51 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 U-shaped large pad
21 00856181003480 48 The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for i The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. The NecCoil 1 .5T GEM Flex Coil is tuned to receive RF frequency corresponding to the proton precession in a 1.5 tesla magnetic field, which is governed by the Larmor equation. MOS Coil, Magnetic Resonance, Specialty 2 5 x 3 x 1 pad
22 00856181003251 25 The NeoCoil 3T l6ch Flex SPEEDER Coils are a receive-only phased array coil syst The NeoCoil 3T l6ch Flex SPEEDER Coils are a receive-only phased array coil system designed to provide high resolution imaging for the upper and lower extremities, chest, abdomen, pelvis. head, neck, and spine. The system is compatible with 20, 3D, parallel and isotropic imaging, as well as, coil signal intensity correction. MOS Coil, Magnetic Resonance, Specialty 2 3T 16ch Flex SPEEDER Medium
23 00856181003138 13 MOS Coil, Magnetic Resonance, Specialty 2 3.0T GEM Flex Coil 16-L Array
24 00856181003916 91 NC143203 The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniformcoverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receivesmagnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magneticfield applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRIscanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam. MOS Coil, Magnetic Resonance, Specialty 2 1.5T 16ch Shoulder Coil (Device)
25 00856181003718 71 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 Family Pack, foam kit
26 00856181003459 45 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 Cable Take-up pad
27 00856181003398 39 The NeoCoil Patient Communication and Entertainment (PCE) System is intended to The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals. LNH System, Nuclear Magnetic Resonance Imaging 2 Wireless Audio Interface
28 00856181003190 19 The NeoCoil Patient Communication and Entertainment (PCE) System is intended to The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals. LNH System, Nuclear Magnetic Resonance Imaging 2 Stand-Alone Wireless Audio Headphones
29 00856181003336 33 The SynChron™ Wireless Vector Gating System for CT is a product used to acquire The SynChron™ Wireless Vector Gating System for CT is a product used to acquire electrocardiogram (ECG) data from a patient and to generate and supply ECG waveform and triggering pulses to the CT scanner to aid in cardiac scanning. The SynChron™ Wireless Vector Gating System for CT includes a Physiologic Acquisition Module (PAM) that connects to the patient using ECG lead wires (Figure 2-2), acquires ECG data, processes the ECG data, and wirelessly transmits the data to the Receive Interface Module (RIM). The RIM will wirelessly receive data from the PAM, create analog ECG waveform and trigger pulse mark, and interfaces with the scanner. The ECG waveform and trigger marks can be seen on the scanner console. JAK System, X-Ray, Tomography, Computed 2 ECG CT Gating Cable
30 00856181003183 18 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coi MOS Coil, Magnetic Resonance, Specialty 2 Pediatric SPEEDER Stabilizer
31 00856181003053 05 The NeoCoil 3.OT 8-Channel Shoulder Array Coil is a multi-element phased arrayre The NeoCoil 3.OT 8-Channel Shoulder Array Coil is a multi-element phased arrayreceive only coil used for obtaining diagnostic images of the shoulder in MagneticResonance Imaging Systems. Compared to predicate devices, the submitteddevice offers easier patient setup and greater SNR due to its compatibility with3.OT MRI scanners.The submitted device consists of semi-flexible foam covered housing, consistingof eight antennas. The antennas are uniquely positioned with the appropriateoverlap to cancel out mutual coupling effects from adjacent antennas ordecoupled from an adjacent antenna using a transformer. Pre-amplifierdecoupling reduces any remaining decoupling between the antennas.The coil is held in place over the imaging area via a cross body strap. A systeminterface cable connects to the coil at the top of the housing. The flexible foamcovered housing along with the body strap enable the proper positioning on thepatient before laying down and holds the coil in place while scanning is beingperformed.To ensure safety, each antenna is equipped with active and passive transmitdecoupling circuits. Active decoupling is achieved via diodes that receive signalsfrom the scanner to turn the coil to a high impedance state during system RFtransmit. Crossed diodes are installed on each antenna acting as passiveswitches. These passive switches provide additional safety in case the activecircuitry does not receive signal from the scanner. MOS Coil, Magnetic Resonance, Specialty 2 3T 8ch Shoulder Coil
32 00856181003923 92 NC143000 The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optim The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings.The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy.During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam. MOS Coil, Magnetic Resonance, Specialty 2 3.0T 16ch Shoulder Coil (System)
33 00856181003640 64 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 General Purpose Support pad
34 00856181003596 59 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 Flex Coils Foot-Ankle Stabilizer
35 00856181003503 50 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 14 x 4 x 2 wedge pad
36 00856181003411 41 The NeoCoil Patient Communication and Entertainment (PCE) System is intended to The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals. LNH System, Nuclear Magnetic Resonance Imaging 2 PCE Pen Panel Transmitter Box
37 00856181003237 23 The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for i The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. MOS Coil, Magnetic Resonance, Specialty 2 1.5T GEM Flex Pediatric Interface, P-Connector
38 00856181003091 09 The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for i The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. The NecCoil 1 .5T GEM Flex Coil is tuned to receive RF frequency corresponding to the proton precession in a 1.5 tesla magnetic field, which is governed by the Larmor equation. MOS Coil, Magnetic Resonance, Specialty 2 1.5T GEM Flex Coil 16-L Array
39 00856181003060 06 The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for i The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. MOS Coil, Magnetic Resonance, Specialty 2 1.5T GEM Flex Interface, P-Connector
40 00856181003800 80 The NeoCoil Wireless Audio System is intended to provide entertainment and facil The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure. LNH System, Nuclear Magnetic Resonance Imaging 2 Technologist Console Interface
41 00856181003787 78 The NeoCoil Wireless Audio System is intended to provide entertainment and facil The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure. LNH System, Nuclear Magnetic Resonance Imaging 2 Scan Room Module
42 00856181003725 72 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coi MOS Coil, Magnetic Resonance, Specialty 2 16Ch Flex SPEEDER Pad Kit
43 00856181003572 57 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 GEM Flex Knee Stabilizer for Curved Tables
44 00856181003534 53 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 11 x 6.5 x 1.5 pad
45 00856181003497 49 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 8 x 3 x 0.5 pad
46 00856181003473 47 These accessory immobilization devices are intended for use in conjunction with These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil. MOS Coil, Magnetic Resonance, Specialty 2 7.5 x 3.5 x 2 pad
47 00856181003435 43 The NeoCoil 1.5T 16‐Channel Flex Coils for Siemens is a system of phased array, The NeoCoil 1.5T 16‐Channel Flex Coils for Siemens is a system of phased array, receive only coils forr imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. The NeoCoil 1.5T 16-Channel Flex Coils for Siemens is tuned to receive RF frequency corresponding to the proton precession in a 1.5 tesla magnetic field, which is governed by the Larmor equation. MOS Coil, Magnetic Resonance, Specialty 2 1.5T 16‐Channel Flex Coils for Siemens, Small
48 00856181003404 40 The NeoCoil Patient Communication and Entertainment (PCE) System is intended to The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals. LNH System, Nuclear Magnetic Resonance Imaging 2 Battery Charger
49 00856181003169 16 The NeoCoil 1.5T l6ch Flex SPEEDER is a receive-only phased array coil system de The NeoCoil 1.5T l6ch Flex SPEEDER is a receive-only phased array coil system designed to provide high resolution imaging for the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine. The system is compatible with 2D, 3D, parallel and isotropic imaging, as well as, coil signal intensity correction. MOS Coil, Magnetic Resonance, Specialty 2 1.5T 16ch Flex SPEEDER Large
50 00856181003121 12 MOS Coil, Magnetic Resonance, Specialty 2 3.0T GEM Flex Coil 16-M Array
Other products with the same Product Code "MOS"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 06970564410901 4598-002-05291 QHC 1H T/R ACS-NT-L Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
2 06970564410895 4598-000-51822 SHNC DRIVERBOX 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
3 06970564410888 4598-000-51893 SYN. BODY COIL 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
4 06970564410871 4598-000-51892 SYN. BODY COIL 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
5 06970564410864 4598-000-51872 SYN. BODY COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
6 06970564410840 4598-000-51821 SHNC DRIVERBOX 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
7 06970564410833 4598-000-51811 SHNC DRIVERBOX 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
8 06970564410826 4598-000-51831 SHNC DRIVERBOX 1.0T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
9 06970564410819 4598-000-51991 MICROSCOPY DRIVER 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
10 06970564410802 4598-009-69781 SYN. BODY COIL 1.5T ODU WITH SLEEVE Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
11 06970564410796 4598-000-51873 SYN. BODY COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
12 06970564410772 4598-000-51894 SYN. BODY COIL 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
13 06970564410758 4598-001-52231 QUAD HEAD COIL T/R 3T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
14 06970564410703 4522-133-17272 Quad Head Coil 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
15 06970564410673 4598-000-20661 3T DS Ped Head-spine 8ch Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
16 06970564410666 4598-000-20681 1.5 T DS Ped Head-spine 8ch Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
17 06970564410659 4598-000-20651 3T DS Ped Torso-cardiac 8ch Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
18 06970564410642 4598-000-20671 1.5T ds Ped Torsocardiac 8ch Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
19 06970564410598 4598-000-51971 MICROSCOPY 23MM COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
20 06970564410581 4598-000-51981 MICROSCOPY 47MM COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
21 06970564410567 4522-133-17242 Spine 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
22 06970564410550 4522-133-17231 SENSE SPINE COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
23 06970564410505 4598-000-51931 SHNC Posterior part 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
24 06970564410499 4598-000-51921 SHNC Anterior part 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
25 06970564410475 4598-000-51951 SHNC Posterior part (1.0T) Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
26 06970564410468 4598-000-51941 SHNC Anterior part (1.0T) Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
27 06970564410451 4522-133-17201 SENSE FLEX-S COIL 3.0T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
28 06970564410437 4522-133-17191 SENSE FLEX S COIL 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
29 06970564410420 4522-133-17181 SENSE FLEX S COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
30 06970564410390 4522-133-17211 SENSE FLEX M 3.0T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
31 06970564410376 4522-133-17172 SENSE FLEX M COIL 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
32 06970564410369 4522-133-17162 SENSE FLEX M COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
33 06970564410338 4522-133-17221 SENSE FLEX-LARGE COIL 3.0T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
34 06970564410314 4522-133-17151 SENSE FLEX-L COIL 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
35 06970564410307 4522-133-17141 SENSE FLEX-L COIL 1.5T VEAM Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
36 06970564410277 4598-000-51892 SYN. BODY COIL 1.5T-WE1 Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
37 06970564410260 4598-000-51871 SYN. BODY COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
38 06970564410239 4598-000-51911 SYN. BODY COIL 1.0T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
39 06970564410215 4522-133-17271 Quad Head Coil 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
40 06970564410192 4522-133-18981 Pediatric NV Spine coil 3T 8ch Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
41 06970564410178 4522-133-18721 Pediatr Body-Cardiac Coil 3T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
42 06970564410154 4522-133-17261 SENSE CARDIAC COIL 1.5T ODU Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
43 06970564410147 4522-133-17251 SENSE CARDIAC COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
44 06970564410116 4598-000-51961 CIRC.COIL C3 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
45 06970564410109 4598-000-51841 CIRC.COIL C1 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
46 06970564410093 4598-000-52031 CIRC.COIL C1 1.0T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
47 06970564410086 4522-150-41021 Wrist-Hand coil 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
48 06970564410062 4522-150-41161 Pediatric NV Spine coil 1.5T 8ch Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
49 06970564410048 4522-150-41131 Pediatric Body-Cardiac COIL 1.5T Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD
50 06970564410024 4522-150-40972 Knee/Foot/Ankle coil Philips SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO., LTD