Duns Number:619834542
Device Description: INTENDED USEAn enzyme-linked immunoassay (ELISA) for the detection of IgG antibodies to co INTENDED USEAn enzyme-linked immunoassay (ELISA) for the detection of IgG antibodies to complexes formed byoxidized low-density lipoprotein (oxLDL) with β2-glycoprotein I (β2GPI) in individuals with systemic lupuserythematosus (SLE) and lupus-like disorders (antiphospholipid syndrome). For In Vitro Diagnostic Use Only.SUMMARY AND EXPLANATION OF THE ASSAYThe antiphospholipid syndrome (APS) is one of the most common causes of acquired hypercoagulability(thrombophilia) It is frequently diagnosed in the context of a systemic autoimmune disorder such asSLE (secondary APS), however, it may also occur in the absence of an obvious underlying disease(primary APS). Oxidative stress and oxLDL formation are common in patients with SLE and APS suggesting an important relationship between lipid peroxidation and clotting activation (hypercoagulability). The presence of circulating IgG anti-oxLDL-β2GPI antibodies seem to be etiologically important. PRINCIPLE OF THE TESTThis test is an indirect ELISA detecting IgG anti-oxLDL-β2GPI antibodies. Diluted serum samples, calibrator(s), and controls are incubated in microwells coated with the oxLDL- β2GPI complex. After the removal of unbound serum proteins by washing, anti-human IgG antibodies, labeled with horseradish peroxidase (HRP), are added. Following another wash, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of IgG anti-oxLDL-β2GPI antibody. Results are obtained by reading the OD of each well in a spectrophotometer. Calibrator sera are provided, with the IgG anti-oxLDL-β2GPI antibody concentration expressed in G Units. A log-log regression analysis is performed with calibrator values plotted against calibrator mean O.D.’s. Controls and patient results are determined from the calibration curve. Refer to product package insert.
Catalog Number
11854
Brand Name
Anti-AtherOxTM IgG Test Kit (OxLDL-B2GPI IgG Antibody)
Version/Model Number
11854
Device Commercial Distribution Status
Not in Commercial Distribution
Commercial Distribution End Date
February 21, 2017
Issuing Agency
In GS1
MRI safety Status
Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)
-
Device labeled as "Not made with natural rubber latex"
-
For Single-Use
Yes
Prescription Use (Rx)
Yes
Over the Counter (OTC)
-
Kit
-
Combination Product
-
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)
-
FDA Premarket Submission
K072032
Product Code
MSV
Product Code Name
System,Test,Antibodies,B2 - Glycoprotein I (B2 - Gpi)
Public Device Record Key
2611afe2-115f-40d5-8020-415fffb22dc8
Public Version Date
July 06, 2018
Public Version Number
3
DI Record Publish Date
August 08, 2016
Package DI Number
None
Quantity per Package
-
Contains DI Package
-
Package Discontinue Date
-
Package Status
-
Package Type
-
Device Class | Device Class Description | No of Devices |
---|---|---|