Duns Number:619834542
Device Description: INTENDED USEDetection and semi-quantitation of IgA anti-phosphatidylserine (aPS) antibodie INTENDED USEDetection and semi-quantitation of IgA anti-phosphatidylserine (aPS) antibodies as an aid for assessingthe risk of thrombosis in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders(anti-phospholipid syndrome). For In Vitro Diagnostic Use.SUMMARY AND EXPLANATION OF THE TESTHigh serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (e.g., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. These antibodies have been associated with an increased risk for recurrent arterial and venous thrombotic events, thrombocytopenia, and fetal loss. Phosphatidylserine is a more physiologically relevant phospholipid due to its presence in cell membranes of endothelial cells and platelets.PRINCIPLE OF THE TESTThe test is an indirect ELISA. Diluted serum/citrated plasma samples, calibrator sera, and controls are incubated in phosphatidylserine coated microwells. β2-glycoprotein I is provided in the sample diluent. After the removal of unbound serum or plasma proteins by washing, antibodies specific for human IgA, labeled with horseradish peroxidase (HRP), are added forming complexes with the phosphatidylserine bound antibodies. Following another washing step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of IgA Antiphosphatidylserine (aPS) antibodies. Results are obtained by reading the O.D. (optical density or absorbance) of each well in a spectrophotometer. IgA calibrator sera are provided, expressed as APS (IgA anti-phosphatidylserine) units. Control and patient results are determined from the calibration curve. Refer to Package Insert.
Catalog Number
10206
Brand Name
REAADS Anti-Phosphatidylserine IgA Semi-Quantitative Test Kit (96 Well)
Version/Model Number
10206
Device Commercial Distribution Status
In Commercial Distribution
Commercial Distribution End Date
-
Issuing Agency
In GS1
MRI safety Status
Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)
-
Device labeled as "Not made with natural rubber latex"
-
For Single-Use
Yes
Prescription Use (Rx)
Yes
Over the Counter (OTC)
-
Kit
-
Combination Product
-
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)
-
FDA Premarket Submission
-
Product Code
MID
Product Code Name
System, Test, Anticardiolipin Immunological
Public Device Record Key
151fba17-509a-47e8-a46f-7e2f286ea508
Public Version Date
March 29, 2018
Public Version Number
2
DI Record Publish Date
July 14, 2016
Package DI Number
None
Quantity per Package
-
Contains DI Package
-
Package Discontinue Date
-
Package Status
-
Package Type
-
Device Class | Device Class Description | No of Devices |
---|---|---|
2 | A medical device with a moderate to high risk that requires special controls. | 27 |