| No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
|---|---|---|---|---|---|---|---|---|
| 1 | 00853359008087 | SBC0629-KTP-150 | SBC0629-KTP-150 | The Sniper is a dual lumen, 150cm, angled tip catheter comprised of an inner gui The Sniper is a dual lumen, 150cm, angled tip catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen to inflate and deflate the balloon. The guidewire/infusion port may be used to inject contrast media or therapeutic agents following removal of the guidewire. The catheter has two radiopaque markers: one marker at the distal tip and another in the center of the balloon. | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper® |
| 2 | 00853359008070 | SBC0629-KTP-130 | SBC0629-KTP-130 | The Sniper is a dual lumen, 130cm, angled tip catheter comprised of an inner gui The Sniper is a dual lumen, 130cm, angled tip catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen to inflate and deflate the balloon. The guidewire/infusion port may be used to inject contrast media or therapeutic agents following removal of the guidewire. The catheter has two radiopaque markers: one marker at the distal tip and another in the center of the balloon. | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper® |
| 3 | 00853359008063 | SBC0629-KTP-110 | SBC0629-KTP-110 | The Sniper is a dual lumen, 110cm, angled tip catheter comprised of an inner gui The Sniper is a dual lumen, 110cm, angled tip catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen to inflate and deflate the balloon. The guidewire/infusion port may be used to inject contrast media or therapeutic agents following removal of the guidewire. The catheter has two radiopaque markers: one marker at the distal tip and another in the center of the balloon. | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper® |
| 4 | 00853359008414 | SBC0629-STR-165 | SBC0629-STR-165 | The Sniper is a dual lumen, 165cm, straight tip catheter comprised of an inner g The Sniper is a dual lumen, 165cm, straight tip catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen to inflate and deflate the balloon. The guidewire/infusion port may be used to inject contrast media or therapeutic agents following removal of the guidewire. The catheter has two radiopaque markers: one marker at the distal tip and another in the center of the balloon. | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper |
| 5 | 00853359008049 | SBC0629-STR-130 | SBC0629-STR-130 | The Sniper is a dual lumen, 130cm, straight tip catheter comprised of an inner g The Sniper is a dual lumen, 130cm, straight tip catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen to inflate and deflate the balloon. The guidewire/infusion port may be used to inject contrast media or therapeutic agents following removal of the guidewire. The catheter has two radiopaque markers: one marker at the distal tip and another in the center of the balloon. | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper |
| 6 | 00853359008032 | SBC0629-STR-150 | SBC0629-STR-150 | The Sniper is a dual lumen, 150cm, straight tip catheter comprised of an inner g The Sniper is a dual lumen, 150cm, straight tip catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen to inflate and deflate the balloon. The guidewire/infusion port may be used to inject contrast media or therapeutic agents following removal of the guidewire. The catheter has two radiopaque markers: one marker at the distal tip and another in the center of the balloon. | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper |
| 7 | 00853359008025 | SBC0629-150 | SBC0629-150 | The Sniper is a dual lumen, 150cm, straight tip catheter comprised of an inner g The Sniper is a dual lumen, 150cm, straight tip catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen to inflate and deflate the balloon. The guidewire/infusion port may be used to inject contrast media or therapeutic agents following removal of the guidewire. The catheter has two radiopaque markers: one marker at the distal tip and another in the center of the balloon. | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper |
| 8 | 00853359008018 | SBC0629-130 | SBC0629-130 | The Sniper is a dual lumen, 130cm, straight tip catheter comprised of an inner g The Sniper is a dual lumen, 130cm, straight tip catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen to inflate and deflate the balloon. The guidewire/infusion port may be used to inject contrast media or therapeutic agents following removal of the guidewire. The catheter has two radiopaque markers: one marker at the distal tip and another in the center of the balloon. | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper |
| 9 | 00853359008001 | SBC0629-110 | SBC0629-110 | The Sniper is a dual lumen, 110cm, straight tip catheter comprised of an inner g The Sniper is a dual lumen, 110cm, straight tip catheter comprised of an inner guidewire/infusion lumen and an outer, annular lumen to inflate and deflate the balloon. The guidewire/infusion port may be used to inject contrast media or therapeutic agents following removal of the guidewire. The catheter has two radiopaque markers: one marker at the distal tip and another in the center of the balloon. | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper |
| 10 | B323SA00900 | SA-0090 | SA-0090 | Infusion catheter with balloon occlusion | MJN | Catheter, Intravascular Occluding, Temporary | 2 | Sniper |
| No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
|---|---|---|---|---|---|---|
| 1 | 00818053023002 | ECL2L6x20 | N/A | ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel configuration. The guidewire lumen or the working lumen is DMSO compatible and can be used for infusion/delivery of diagnostic and therapeutic devices. The inflation lumen is used for the inflation and deflation of the balloon. The inflation and deflation of the balloon can be achieved independently of the presence of the guidewire. ECLIPSE 2L balloon catheter is equipped with a non-detachable low inflation pressure super compliant balloon welded to the distal end of the catheter. | ECLIPSE 2L | BALT USA LLC |
| 2 | 00818053022982 | ECL2L6x15 | N/A | ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel configuration. The guidewire lumen or the working lumen is DMSO compatible and can be used for infusion/delivery of diagnostic and therapeutic devices. The inflation lumen is used for the inflation and deflation of the balloon. The inflation and deflation of the balloon can be achieved independently of the presence of the guidewire. ECLIPSE 2L balloon catheter is equipped with a non-detachable low inflation pressure super compliant balloon welded to the distal end of the catheter. | ECLIPSE 2L | BALT USA LLC |
| 3 | 00818053022968 | ECL2L6x12 | N/A | ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel configuration. The guidewire lumen or the working lumen is DMSO compatible and can be used for infusion/delivery of diagnostic and therapeutic devices. The inflation lumen is used for the inflation and deflation of the balloon. The inflation and deflation of the balloon can be achieved independently of the presence of the guidewire. ECLIPSE 2L balloon catheter is equipped with a non-detachable low inflation pressure super compliant balloon welded to the distal end of the catheter. | ECLIPSE 2L | BALT USA LLC |
| 4 | 00818053022944 | ECL2L6x9 | N/A | ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel configuration. The guidewire lumen or the working lumen is DMSO compatible and can be used for infusion/delivery of diagnostic and therapeutic devices. The inflation lumen is used for the inflation and deflation of the balloon. The inflation and deflation of the balloon can be achieved independently of the presence of the guidewire. ECLIPSE 2L balloon catheter is equipped with a non-detachable low inflation pressure super compliant balloon welded to the distal end of the catheter. | ECLIPSE 2L | BALT USA LLC |
| 5 | 00818053022937 | ECL2L6x7SN | N/A | ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel configuration. The guidewire lumen or the working lumen is DMSO compatible and can be used for infusion/delivery of diagnostic and therapeutic devices. The inflation lumen is used for the inflation and deflation of the balloon. The inflation and deflation of the balloon can be achieved independently of the presence of the guidewire. ECLIPSE 2L balloon catheter is equipped with a non-detachable low inflation pressure super compliant balloon welded to the distal end of the catheter. | ECLIPSE 2L | BALT USA LLC |
| 6 | 00818053022920 | ECL2L6x7 | N/A | ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel ECLIPSE 2L balloon catheters are catheters with dual lumen arranged in parallel configuration. The guidewire lumen or the working lumen is DMSO compatible and can be used for infusion/delivery of diagnostic and therapeutic devices. The inflation lumen is used for the inflation and deflation of the balloon. The inflation and deflation of the balloon can be achieved independently of the presence of the guidewire. ECLIPSE 2L balloon catheter is equipped with a non-detachable low inflation pressure super compliant balloon welded to the distal end of the catheter. | ECLIPSE 2L | BALT USA LLC |
| 7 | 00813132024840 | 590-001AB | 590-001 | Bridge Occlusion Catheter - 80 mm Length Balloon | Bridge™ | SPECTRANETICS CORPORATION |
| 8 | 00813132024666 | 590-001AA | 590-001 | Bridge Occlusion Catheter - 80 mm Length Balloon | Bridge™ | SPECTRANETICS CORPORATION |
| 9 | 00813132023263 | 590-001 | 590-001 | Bridge Occlusion Catheter - 80 mm Length Balloon | Bridge™ Occlusion Balloon | SPECTRANETICS CORPORATION |
| 10 | 00811806011530 | Sizing Balloon II | 9-SB-034 | Sizing Balloon II | Amplatzer™ | AGA MEDICAL CORPORATION |
| 11 | 00811806011523 | Sizing Balloon II | 9-SB-024 | Sizing Balloon II | Amplatzer™ | AGA MEDICAL CORPORATION |
| 12 | 00811806011516 | Sizing Balloon II | 9-SB-018 | Sizing Balloon II | Amplatzer™ | AGA MEDICAL CORPORATION |
| 13 | 00763000294595 | 104-4530 | BALLOON SYSTEM 104-4530 V20 HYPERGLIDE | HyperGlide | MICRO THERAPEUTICS, INC. | |
| 14 | 00763000294564 | 104-4520 | BALLOON SYSTEM 104-4520 V20 HYPERGLIDE | HyperGlide | MICRO THERAPEUTICS, INC. | |
| 15 | 00763000294533 | 104-4515 | BALLOON SYSTEM 104-4515 V20 HYPERGLIDE | HyperGlide | MICRO THERAPEUTICS, INC. | |
| 16 | 00763000294502 | 104-4315 | BALLOON SYSTEM 104-4315 V20 HYPERGLIDE | HyperGlide | MICRO THERAPEUTICS, INC. | |
| 17 | 00763000294472 | 104-4310 | BALLOON SYSTEM 104-4310 V20 HYPERGLIDE | HyperGlide | MICRO THERAPEUTICS, INC. | |
| 18 | 00763000294441 | 104-4132 | BALLOON SYSTEM 104-4132 V20 HYPERGLIDE | HyperGlide | MICRO THERAPEUTICS, INC. | |
| 19 | 00763000294410 | 104-4127 | BALLOON SYSTEM 104-4127 V20 HYPERGLIDE | HyperGlide | MICRO THERAPEUTICS, INC. | |
| 20 | 00763000294380 | 104-4113 | BALLOON SYSTEM 104-4113 V20 HYPERGLIDE | HyperGlide | MICRO THERAPEUTICS, INC. | |
| 21 | 00763000294359 | 104-4112 | BALLOON SYSTEM 104-4112 V20 HYPERGLIDE | HyperGlide | MICRO THERAPEUTICS, INC. | |
| 22 | 00763000294328 | 104-4770 | BALLOON SYSTEM 104-4770 V20 HYPERFORM | HyperForm | MICRO THERAPEUTICS, INC. | |
| 23 | 00763000294298 | 104-4715 | BALLOON SYSTEM 104-4715 V20 HYPERFORM | HyperForm | MICRO THERAPEUTICS, INC. | |
| 24 | 00763000294267 | 104-4470 | BALLOON SYSTEM 104-4470 V20 HYPERFORM | HyperForm | MICRO THERAPEUTICS, INC. | |
| 25 | 00763000294236 | 104-4420 | BALLOON SYSTEM 104-4420 V20 HYPERFORM | HyperForm | MICRO THERAPEUTICS, INC. | |
| 26 | 00763000294205 | 104-4415 | BALLOON SYSTEM 104-4415 V20 HYPERFORM | HyperForm | MICRO THERAPEUTICS, INC. | |
| 27 | 00763000294175 | 104-4370 | BALLOON SYSTEM 104-4370 V20 HYPERFORM | HyperForm | MICRO THERAPEUTICS, INC. | |
| 28 | 00763000294144 | 104-4153 | BALLOON SYSTEM 104-4153 V20 HYPERFORM | HyperForm | MICRO THERAPEUTICS, INC. | |
| 29 | 00733132639489 | MOB37 | MOB37 | MOB 10-37mm x 4.0cm x 90cm | GORE Molding Occlusion Balloon Catheter | W. L. GORE & ASSOCIATES, INC. |
| 30 | 00690103043754 | 62080822F | 62080822F | FOGARTY OCCLUSION CATHETER 8/22F 80CM | FOGARTY | EDWARDS LIFESCIENCES LLC |
| 31 | 00690103043747 | 62080814F | 62080814F | FOGARTY OCCLUSION CATHETER 8/14F 80CM | FOGARTY | EDWARDS LIFESCIENCES LLC |
| 32 | 00690103043730 | 620405F | 620405F | FOGARTY OCCLUSION CATHETER 5F 40CM | FOGARTY | EDWARDS LIFESCIENCES LLC |
| 33 | 00690103043723 | 620404F | 620404F | FOGARTY OCCLUSION CATHETER 4F 40CM | FOGARTY | EDWARDS LIFESCIENCES LLC |
| 34 | 00690103043716 | 620403F | 620403F | FOGARTY OCCLUSION CATHETER 3F 40CM | FOGARTY | EDWARDS LIFESCIENCES LLC |
| 35 | B380T39F300 | T39F30 | LMI CAROTID ENDARTERECTOMY SHUNT CATHETER | LUCAS MEDICAL INC | ||
| 36 | B380T39F150 | T39F15 | LMI CAROTID ENDARTERECTOMY SHUNT CATHETER | LUCAS MEDICAL INC | ||
| 37 | B380T38F300 | T38F30 | LMI CAROTID ENDARTERECTOMY SHUNT CATHETER | LUCAS MEDICAL INC | ||
| 38 | B380T38F150 | T38F15 | LMI CAROTID ENDARTERECTOMY SHUNT CATHETER | LUCAS MEDICAL INC | ||
| 39 | B380T311F300 | T311F30 | LMI CAROTID ENDARTERECTOMY SHUNT CATHETER | LUCAS MEDICAL INC | ||
| 40 | B380T311F150 | T311F15 | LMI CAROTID ENDARTERECTOMY SHUNT CATHETER | LUCAS MEDICAL INC | ||
| 41 | B380NL9IRR30D0 | NL9IRR30D | LMI BILUMEN IRRIGATION ARTERIAL EMBOLECTOMY CATHETER | LUCAS MEDICAL INC | ||
| 42 | B380NL12IRR30D0 | NL12IRR30D | LMI BILUMEN IRRIGATION ARTERIAL EMBOLECTOMY CATHETER | LUCAS MEDICAL INC | ||
| 43 | B3809FCESB300 | 9FCESB30 | LMI CAROTID ENDARTERECTOMY SHUNT CATHETER | LUCAS MEDICAL INC | ||
| 44 | B3809FCESB150 | 9FCESB15 | LMI CAROTID ENDARTERECTOMY SHUNT CATHETER | LUCAS MEDICAL INC | ||
| 45 | B3809FCES300 | 9FCES30 | CAROTID ENDARTERECTOMY SHUNT | LUCAS MEDICAL INC | ||
| 46 | B3809FCES150 | 9FCES15 | CAROTID ENDARTERECTOMY SHUNT | LUCAS MEDICAL INC | ||
| 47 | B3809FCBS4004020 | 9FCBS400-40-2 | LMI CAROTID SHUNT WITH SAFETY BALLOON CATHETER | LUCAS MEDICAL INC | ||
| 48 | B3809FCBS4004010 | 9FCBS400-40-1 | LMI CAROTID SHUNT WITH SAFETY BALLOON CATHETER | LUCAS MEDICAL INC | ||
| 49 | B3809FCBS1001020 | 9FCBS100-10-2 | LMI CAROTID SHUNT WITH SAFETY BALLOON CATHETER | LUCAS MEDICAL INC | ||
| 50 | B3809FCBS1001010 | 9FCBS100-10-1 | LMI CAROTID SHUNT WITH SAFETY BALLOON CATHETER | LUCAS MEDICAL INC |