No | Primary DI | Version or Model | Catalog Number | Device Description | Product Code | Product Code Name | Device Class | Brand Name |
---|---|---|---|---|---|---|---|---|
1 | 00851725007160 | RNS-6804-7450 | RNS-6804-7450 | No Audio Remote Network Station with Dell OptiPlex 24” All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | N/A |
2 | 00851725007153 | RNS-6803-7450 | RNS-6803-7450 | Remote Network Station with Dell OptiPlex 24” All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | N/A |
3 | 00851725007146 | RNS-6804-3464 | RNS-6804-3464 | No Audio Remote Network Station with Dell Inspiron 24” All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | N/A |
4 | 00851725007139 | RNS-6803-3464 | RNS-6803-3464 | Remote Network Station with Dell Inspiron 24” All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | N/A |
5 | 00851725007122 | RNS-9703-242 | RNS-9703-242 | Remote Network Station with 24” display | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | NA |
6 | 00851725007092 | CGS-9001 | CGS-9001 | Communication Gateway Server CGS-9001 (Pager Commnunication Gateway Server) | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | NA |
7 | 00851725007009 | RNS-9703-019 | RNS-9703-019 | Remote Network Station with 19” display | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | NA |
8 | 00851725007108 | QP-985P | QP-985P | NetKonnect - LT | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | NetKonnect |
9 | 00851725007085 | BS-984P | BS-984P | NetKonnect Option BS-984P (RNS Option) | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | NetKonnect |
10 | 00851725007078 | BS-983P | BS-983P | NetKonnect Option BS-983P (ReportKonnect Option) | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | NetKonnect |
11 | 00851725007061 | BS-982P | BS-982P | NetKonnect Option BS-982P (1000 Accounts) | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | NetKonnect |
12 | 00851725007054 | BS-981P | BS-981P | NetKonnect Option BS-981P (15 Accounts) | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | NetKonnect |
13 | 00851725007047 | QP-983P | QP-983P | NetKonnect | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | NetKonnect |
14 | 00851725007214 | EDNS-9001-AVGH977 | EDNS-9001-AVGH977 | Prefense - Early Detection and Notification System (Vital Signs Central) PC | MHX,DRG | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS),TRANSMITTER MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS),TRANSMITTERS AND RECEIVERS, PHYSIOLOGICAL SIGNAL, RADIOFREQUENCY | 2 | Prefense |
15 | 00851725007030 | EDNS-WS24 | EDNS-WS24 | Prefense 24" display | DRG,MHX | TRANSMITTERS AND RECEIVERS, PHYSIOLOGICAL SIGNAL, RADIOFREQUENCY,MONITOR, PHYSIO TRANSMITTERS AND RECEIVERS, PHYSIOLOGICAL SIGNAL, RADIOFREQUENCY,MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Prefense |
16 | 00851725007023 | EDNS-9001 | EDNS-9001 | Prefense - Early Detection and Notification System (PC) | MHX,DRG | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS),TRANSMITTER MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS),TRANSMITTERS AND RECEIVERS, PHYSIOLOGICAL SIGNAL, RADIOFREQUENCY | 2 | Prefense |
17 | 00851725007313 | NGNK-6804 | NGNK-6804 | NGNK no-audio, non-touch, unicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Next Generation NetKonnect |
18 | 00851725007344 | NGNK-6804-T | NGNK-6804-T | NGNK no-audio, touch, unicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Next Generation NetKonnect |
19 | 00851725007337 | NGNK-6804-M | NGNK-6804-M | NGNK no-audio, non-touch, multicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Next Generation NetKonnect |
20 | 00851725007320 | NGNK-6803-T | NGNK-6803-T | NGNK audio, touch, unicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Next Generation NetKonnect |
21 | 00851725007306 | NGNK-6803 | NGNK-6803 | NGNK audio, non-touch, unicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Next Generation NetKonnect |
22 | 00851725007115 | NGNK-6803-M | NGNK-6803-M | NGNK audio, non-touch, multicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Next Generation NetKonnect |
23 | 00851725007290 | RNS-6803-7490 | RNS-6803-7490 | Remote Network Station with Dell OptiPlex 7490 23.8” All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
24 | 00851725007283 | RNS-6804-7490 | RNS-6804-7490 | No Audio Remote Network Station with Dell OptiPlex 7490 23.8" All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
25 | 00851725007276 | RNS-6803-7490-U | RNS-6803-7490-U | Remote Network Station with Dell OptiPlex 7490 23.8” All-In-One Computer SW 02-18 unicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
26 | 00851725007269 | RNS-6804-7490-U | RNS-6804-7490-U | No Audio Remote Network Station with Dell OptiPlex 7490 23.8" All-In-One Compute No Audio Remote Network Station with Dell OptiPlex 7490 23.8" All-In-One Computer SW 02-18 unicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
27 | 00851725007252 | RNS-6803-7480-U | RNS-6803-7480-U | Remote Network Station with Dell OptiPlex 7480 23.8” All-In-One Computer SW 02-18 unicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
28 | 00851725007245 | RNS-6804-7480-U | RNS-6804-7480-U | No Audio Remote Network Station with Dell OptiPlex 7480 23.8" All-In-One Compute No Audio Remote Network Station with Dell OptiPlex 7480 23.8" All-In-One Computer SW 02-18 unicast | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
29 | 00851725007238 | RNS-6803-7480 | RNS-6803-7480 | Remote Network Station with Dell OptiPlex 7480 23.8” All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
30 | 00851725007221 | RNS-6804-7480 | RNS-6804-7480 | No Audio Remote Network Station with Dell OptiPlex 7480 23.8" All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
31 | 00851725007207 | RNS-6804-7470 | RNS-6804-7470 | No Audio Remote Network Station with Dell OptiPlex 7470 23.8" All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
32 | 00851725007191 | RNS-6803-7470 | RNS-6803-7470 | Remote Network Station with Dell OptiPlex 7470 23.8” All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
33 | 00851725007184 | RNS-6803-7460 | RNS-6803-7460 | Remote Network Station with Dell OptiPlex 7460 23.8" All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
34 | 00851725007177 | RNS-6804-7460 | RNS-6804-7460 | No Audio Remote Network Station with Dell OptiPlex 7460 23.8" All-In-One Computer | MHX | MONITOR, PHYSIOLOGICAL, PATIENT(WITH ARRHYTHMIA DETECTION OR ALARMS) | 2 | Remote Network Station |
No | Primary DI | Version or Model | Catalog Number | Device Description | Brand Name | Organization Name |
---|---|---|---|---|---|---|
1 | 30884838085153 | IntelliVue NMT Hand-Adapter | 989803199211 | IntelliVue NMT Hand Adapter for use with IntelliVue NMT Patient Cable 9898031745 IntelliVue NMT Hand Adapter for use with IntelliVue NMT Patient Cable 989803174581 and IntelliVue Neuro Muscular Transmission Module 865383. Adapter is reusable. 1 Sales Unit = 10 each | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
2 | 20884838072248 | Flow Sensor Neonatal | 989803144671 | The M2786A in combination with the spirometry module M1014A is designed to allow The M2786A in combination with the spirometry module M1014A is designed to allow measurement of airway pressures, flow, minute volume, tidal volume, airway compliance, airway resistance and CO2. | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
3 | 20884838072231 | Flow Sensor Adult / Pediatric | 989803144661 | Flow Sensor Adult / Pediatric | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
4 | 20884838072224 | 989803144701 | 989803144701 | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH | |
5 | 20884838072217 | 989803144691 | 989803144691 | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH | |
6 | 20884838072200 | 989803144681 | 989803144681 | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH | |
7 | 20884838072187 | Single-Patient use Infant Airway Adapter | 989803142671 | Single-Patient use Infant Airway Adapter | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
8 | 20884838072170 | Single-Patient use Adult Airway Adapter | 989803142661 | Single-Patient use Adult Airway Adapter | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
9 | 20884838072132 | Straight Sample Line H | 989803144571 | Straight Sample Line H | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
10 | 20884838072125 | Straight Sample Line | 989803144561 | Straight Sample Line | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
11 | 20884838072118 | Airway Adapter Set H - ET =<4.0 mm | 989803144551 | Airway Adapter Set H - ET =<4.0 mm | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
12 | 20884838072101 | Airway Adapter Set H - ET >4.0 mm | 989803144541 | Airway Adapter Set H - ET >4.0 mm | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
13 | 20884838072095 | Airway Adapter Set - ET >4.0 mm | 989803144521 | Airway Adapter Set - ET >4.0 mm | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
14 | 20884838072071 | CO2 / O2 Oral-Nasal Cannula - Pediatric | 989803144511 | CO2 / O2 Oral-Nasal Cannula - Pediatric | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
15 | 20884838072064 | CO2 / O2 Oral-Nasal Cannula - Adult | 989803144501 | CO2 / O2 Oral-Nasal Cannula - Adult | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
16 | 20884838072057 | CO2 Oral-Nasal Cannula - Pediatric | 989803144491 | CO2 Oral-Nasal Cannula - Pediatric | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
17 | 20884838072040 | CO2 Oral-Nasal Cannula - Adult | 989803144481 | CO2 Oral-Nasal Cannula - Adult | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
18 | 20884838072033 | CO2 / O2 Nasal Cannula - Pediatric | 989803144461 | CO2 / O2 Nasal Cannula - Pediatric | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
19 | 20884838072026 | CO2 / O2 Nasal Cannula - Adult | 989803144451 | CO2 / O2 Nasal Cannula - Adult | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
20 | 20884838072019 | CO2 Nasal Cannula - Infant | 989803144441 | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH | |
21 | 20884838072002 | CO2 Nasal Cannula - Pediatric | 989803144431 | CO2 Nasal Cannula - Pediatric | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
22 | 20884838071999 | CO2 Nasal Cannula - Adult | 989803144421 | CO2 Nasal Cannula - Adult | NA | PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH |
23 | 20884838071463 | CapnoLine H O2/Adult | M4680A | CapnoLine H O2/Adult | CapnoLine/Microstream | PHILIPS MEDICAL SYSTEMS HSG |
24 | 20884838071456 | SMART CAPNOLINE plus, ADULT, intermed | M2526A | SMART CAPNOLINE plus, ADULT, intermed | Smart CapnoLine/Microstream | PHILIPS MEDICAL SYSTEMS HSG |
25 | 20884838071449 | SMART CAPNOLINE, PEDIATRIC | 989803129761 | SMART CAPNOLINE, PEDIATRIC | Smart CapnoLine/Microstream | PHILIPS MEDICAL SYSTEMS HSG |
26 | 20884838071432 | SMART CAPNOLINE O2 plus, ADULT, intermed | M2522A | SMART CAPNOLINE O2 plus, ADULT, intermed | Smart CapnoLine/Microstream | PHILIPS MEDICAL SYSTEMS HSG |
27 | 20884838071401 | Smart CapnoLine O2 Plus Long, Adult | 989803160281 | Smart CapnoLine O2 Plus Long, Adult | Smart CapnoLine/Microstream | PHILIPS MEDICAL SYSTEMS HSG |
28 | 20884838071388 | FilterLine H Set Infant/Neonatal | 989803105561 | FilterLine/Microstream | PHILIPS MEDICAL SYSTEMS HSG | |
29 | 20884838028726 | 989803179611 | 989803179611 | Genius 2 Probe Cover (CE marked) | Genius 2 | PHILIPS MEDICAL SYSTEMS HSG |
30 | 20884838028719 | Genius 2 Probe Cover (non-CE marked) | 989803179381 | Genius 2 Probe Cover (non-CE marked) | Genius 2 | PHILIPS MEDICAL SYSTEMS HSG |
31 | 18800003428929 | M30 | M30M-5PNXAH | The M30 is intended to be used to monitor electrocardiography (ECG), heart rate The M30 is intended to be used to monitor electrocardiography (ECG), heart rate (HR), noninvasive blood pressure (NIBP) - systolic, diastolic and mean arterial pressures, functional arterial oxygen saturation (SpO2), pulse rate (PR), respiration rate (RR), capnography (EtCO2 and InCO2) temperature (Temp) for adult, pediatric and neonatal patients in all areas of a hospital and hospital-type facilities. Monitor users should be skilled at the level of a technician, doctor, nurse or medical specialist. The M30 is suitable for continuous operation. | Patient Monitor M30 | MEDIANA.CO.LTD |
32 | 18800003427847 | M30 | M30M-3PXAH | M30 is intended to be used to monitor electrocardiography (ECG), heart rate (HR) M30 is intended to be used to monitor electrocardiography (ECG), heart rate (HR), noninvasive blood pressure (NIBP) - systolic, diastolic and mean arterial pressures, functional arterial oxygen saturation (SpO2), pulse rate (PR), respiration rate (RR), capnography (EtCO2 and InCO2) temperature (Temp) for adult, pediatric and neonatal patients in all areas of a hospital and hospital-type facilities. Monitor users should be skilled at the level of a technician, doctor, nurse or medical specialist. The M30 is suitable for continuous operation. | Patient Monitor M30 | MEDIANA.CO.LTD |
33 | 18800003427205 | M30 | M30M-1PXAH | The M30 is intended to be used to monitor electrocardiography (ECG), heart rate The M30 is intended to be used to monitor electrocardiography (ECG), heart rate (HR), noninvasive blood pressure (NIBP) - systolic, diastolic and mean arterial pressures, functional arterial oxygen saturation (SpO2), pulse rate (PR), respiration rate (RR), capnography (EtCO2 and InCO2) temperature (Temp) for adult, pediatric and neonatal patients in all areas of a hospital and hospital-type facilities. Monitor users should be skilled at the level of a technician, doctor, nurse or medical specialist. The M30 is suitable for continuous operation. | Patient Monitor M30 | MEDIANA.CO.LTD |
34 | 15060484630027 | PN1111 | The Intelesens Aingeal is used to monitor and transmit physiological data to a r The Intelesens Aingeal is used to monitor and transmit physiological data to a remote application for display or analysis by a clinician. The device can be worn by ambulatory or non-ambulatory adult patients in a healthcare environment to support clinical staff when they are carrying out their routine observations or when a patient would otherwise be in an unmonitored or unobserved situation.This re-usable device is intend to be used on the patient for short term periods only.The device is intended to be used on adult patients for monitoring of ECG, respiration, heart rate, skin temperature and activity levels in a healthcare setting.The device can be used where information on ECG, respiration, heart rate, skin temperature, and activity levels would be useful.The device uses on-board ECG arrhythmia detection algorithms to automatically record and send ECG data if the user is suspected to be experiencing an arrhythmia event. The device transmits the data to the remote application at user defined intervals or upon the detection of an arrhythmia event (arrhythmia or threshold breach). | Aingeal | INTELESENS LIMITED | |
35 | 14931921903527 | YP-845T | YP-845T | Disposable cuff for thigh | NA | NIHON KOHDEN CORPORATION |
36 | 14931921903510 | YP-844T | YP-844T | Disposable cuff for adults, large | NA | NIHON KOHDEN CORPORATION |
37 | 14931921903503 | YP-843T | YP-843T | Disposable cuff for adults, standard | NA | NIHON KOHDEN CORPORATION |
38 | 14931921903497 | YP-842T | YP-842T | Disposable cuff for adults, small | NA | NIHON KOHDEN CORPORATION |
39 | 14931921903480 | YP-841T | YP-841T | Disposable cuff for children | NA | NIHON KOHDEN CORPORATION |
40 | 14931921903473 | YP-840T | YP-840T | Disposable cuff for infants | NA | NIHON KOHDEN CORPORATION |
41 | 14931921899295 | YG-214T | YG-214T | Airway adapter for neonate and child | NA | NIHON KOHDEN CORPORATION |
42 | 14931921898359 | TL-535U | TL-535U | SpO2 Probe, Disposable, Neonates and Preterm Infants | NA | NIHON KOHDEN CORPORATION |
43 | 14931921890025 | YG-213T | YG-213T | Airway adapter for neonate and child, TG-970P | NA | NIHON KOHDEN CORPORATION |
44 | 14931921885694 | YG-211T | YG-211T | Airway adapter for adult and child | NA | NIHON KOHDEN CORPORATION |
45 | 14931921882648 | YP-817P | YP-817P | Disposable cuff for thigh | NA | NIHON KOHDEN CORPORATION |
46 | 14931921882624 | YP-816P | YP-816P | Disposable cuff for adults, extra large | NA | NIHON KOHDEN CORPORATION |
47 | 14931921882600 | YP-815P | YP-815P | Disposable cuff for adults, large | NA | NIHON KOHDEN CORPORATION |
48 | 14931921882587 | YP-814P | YP-814P | Disposable cuff for adults, medium large | NA | NIHON KOHDEN CORPORATION |
49 | 14931921882563 | YP-813P | YP-813P | Disposable cuff for adults, standard | NA | NIHON KOHDEN CORPORATION |
50 | 14931921882549 | YP-811P | YP-811P | Disposable cuff for children | NA | NIHON KOHDEN CORPORATION |