Other products from "AVINGER, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00851354004370 A400 A400 The Pantheris System is intended to remove plaque (atherectomy) from partially o The Pantheris System is intended to remove plaque (atherectomy) from partially occluded vessels in the peripheral vasculature with a reference diameter of 3.0 mm to 7.0 mm, using OCT-assisted orientation and imaging. The system is an adjunct to fluoroscopy by providing images of vessel lumen, wall structures and vessel morphologies. NQQ,MCW System, Imaging, Optical Coherence Tomography (Oct),Catheter, Peripheral, Atherectomy 2 Pantheris
2 00851354004301 U250 U250 Lightbox Umbilical is intended for use in peripheral vascular procedures in conj Lightbox Umbilical is intended for use in peripheral vascular procedures in conjunction with a compatible Avinger product. NQQ System, Imaging, Optical Coherence Tomography (Oct) 2 Lightbox Umbilical
3 00851354004127 U100 U100 Lightbox Umbilical is intended for use in peripheral vascular procedures in conj Lightbox Umbilical is intended for use in peripheral vascular procedures in conjunction with a compatible Avinger product. PDU Catheter For Crossing Total Occlusions 2 Lightbox Umbilical
4 00851354004141 P135 P135 "The Ocelot PIXL System consists of the Ocelot PIXL Catheter (“Ocelot PIXL”), th "The Ocelot PIXL System consists of the Ocelot PIXL Catheter (“Ocelot PIXL”), the Lightbox console (“Lightbox”), and the Lightbox Umbilical (“Umbilical”). This system combines the use of Avinger’s peripheral catheter designs and an Optical Coherence Tomography (OCT) intravascular orientation and imaging tool. The Ocelot PIXL System is intended to cross chronic total occlusions in the peripheral vasculature while simultaneously providing OCT visualization to help orient the distal tip of the Ocelot PIXL to support the primary intended use. Use of Ocelot PIXL in conjunction with Lightbox allows for OCT imaging as an adjunct to fluoroscopy which facilitates intravascular orientation of the catheter. See Lightbox Operator’s Manual and Umbilical IFU for guidance on setting up and using the Lightbox and Umbilical, respectively. Ocelot PIXL is available in 2 different lengths, 135cm working length and 150cm working length.Ocelot PIXL is an over-the-wire device compatible with a 5F sheath and 0.014” guidewire. It consists of a catheter shaft with handle assembly at the proximal end and a distal tip designed to cross CTOs. A locking luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire (i.e., Lumen Flush Port). The catheter is sterilized by ethylene oxide and is intended for single use only. " PDU Catheter For Crossing Total Occlusions 2 Ocelot PIXL
5 00851354004417 A140-SV A140-SV The Pantheris SV System is intended to remove plaque (atherectomy) from partiall The Pantheris SV System is intended to remove plaque (atherectomy) from partially occluded vessels in the peripheral vasculature with a reference diameter of 2.0 mm to 4.0 mm, using OCT-assisted orientation and imaging. The system is an adjunct to fluoroscopy by providing images of vessel lumen, wall structures and vessel morphologies. NQQ,MCW System, Imaging, Optical Coherence Tomography (Oct),Catheter, Peripheral, Atherectomy 2 Pantheris SV
6 00851354004233 O250 O250 The Ocelot System is intended to facilitate the intraluminal placement of conven The Ocelot System is intended to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention using OCT-assisted orientation and imaging. The system is an adjunct to fluoroscopy by providing images of vessel lumen and wall structures. The Ocelot System is contraindicated for use in the iliac, coronary, cerebral, renal or carotid vasculature. PDU Catheter For Crossing Total Occlusions 2 Ocelot IV
7 00851354004073 J100 J100 Juicebox is an optional accessory to facilitate catheter tip rotation when using Juicebox is an optional accessory to facilitate catheter tip rotation when using a compatible Avinger catheter. It consists of a handle with a Rotation Toggle Switch and a Release Button. Juicebox is designed to be placed over the catheter handle. This accessory is irradiated for sterility and is intended for single use only. When Juicebox is properly placed over a catheter handle, it locks into place. Depressing the Rotation Toggle Switch activates the power for rotation in either the clockwise or counterclockwise directions. The Release Button releases Juicebox so that it can be removed from the catheter handle.The Juicebox is an optional accessory that may be used to facilitate catheter tip rotation when using a compatible Avinger catheter. DQY Catheter, Percutaneous 2 Juicebox
8 00851354004059 E550 E550 "Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wi "Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wire device with a working length of 150 cm. It consists of a catheter shaft with handle assembly at the proximal end and an atraumatic Distal Tip. A locking Luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only.The Distal Tip houses Spiral Flutes and allows atraumatic advancement of the catheter through the vasculature. The pre-shaped Distal Tip is made of a malleable material and may be reshaped as needed by the user. The deflection of the Distal Tip is visible under fluoroscopic guidance.The handle assembly consists of a Handle Body, Rotator, and Luer. The Handle Body controls rotational orientation of the catheter, including the flexible Distal Tip. The Rotator controls the rotational movement of the Distal Tip, independent of the catheter orientation. The Luer is provided at the proximal end to facilitate fluid flush and the entry/exit of the guidewire. Kittycat 2 is intended to create a channel in totally occluded peripheral vessels. The device may also be used to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. " DQY Catheter, Percutaneous 2 Kittykat II
9 00851354004042 W550` W550 "Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wi "Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wire device with a working length of 150 cm. It consists of a catheter shaft with handle assembly at the proximal end and an atraumatic Distal Tip. A locking Luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only.The Distal Tip houses Spiral Flutes and allows atraumatic advancement of the catheter through the vasculature. The pre-shaped Distal Tip is made of a malleable material and may be reshaped as needed by the user. The deflection of the Distal Tip is visible under fluoroscopic guidance.The handle assembly consists of a Handle Body, Rotator, and Luer. The Handle Body controls rotational orientation of the catheter, including the flexible Distal Tip. The Rotator controls the rotational movement of the Distal Tip, independent of the catheter orientation. The Luer is provided at the proximal end to facilitate fluid flush and the entry/exit of the guidewire. Kittycat 2 is intended to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Kittycat 2 Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature.Kittycat 2 is intended to be used to support steerable guidewires in accessing discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices. It may also be used to deliver saline or contrast." DQY Catheter, Percutaneous 2 Kittykat II
10 00851354004387 A400X A400X The Pantheris System is intended to remove plaque (atherectomy) from partially o The Pantheris System is intended to remove plaque (atherectomy) from partially occluded vessels in the peripheral vasculature with a reference diameter of 3.0 mm to 7.0 mm, using OCT-assisted orientation and imaging. The system is an adjunct to fluoroscopy by providing images of vessel lumen, wall structures and vessel morphologies. NQQ,MCW System, Imaging, Optical Coherence Tomography (Oct),Catheter, Peripheral, Atherectomy 2 Pantheris
11 00851354004264 SD100 SD100 The Sterile Drape is designed to function as a protective barrier between the st The Sterile Drape is designed to function as a protective barrier between the sterile and non-sterile environments during surgical procedures KKK Sudan Iv 1 Sterile Drape
12 00851354004189 O200 O200 The Ocelot System is intended to facilitate the intraluminal placement of conven The Ocelot System is intended to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention using OCT-assisted orientation and imaging. The system is an adjunct to fluoroscopy by providing images of vessel lumen and wall structures. The Ocelot System is contraindicated for use in the iliac, coronary, cerebral, renal or carotid vasculature. NQQ,DQY System, Imaging, Optical Coherence Tomography (Oct),Catheter, Percutaneous 2 Ocelot III
13 00851354004028 E400 E400 "The Wildcat CTO Catheter is intended to create a channel in totally occluded pe "The Wildcat CTO Catheter is intended to create a channel in totally occluded peripheral vessels. The device may also be used to faciliate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Wildcat CTO Catheter is a 6F sheath and 0.035"" guidewire compatible over-the-wire device. It consists of a catheter shaft with a handle assembly at the porximal end and an atraumatic Distal Tip. A locking Luer connector at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only. At the Slider’s most proximal location, the Wedges are in the retracted position. At the mid-point location, the Wedges are deployed. Moving the slider distal from this point initiates deflection of the Distal Tip. The amount of tip deflection increases with distal movement of the slider. At the most distal location, the Wedges remain fully deployed and the Distal Tip is at maximum deflection. The deployment and retraction of the Wedges as well as the deflection of the Distal Tip is visible under fluoroscopic guidance.The handle assembly consists of a Handle Body, Rotator, Tip Indicator, Slider, and Luer. The Handle Body controls rotational orientation of the catheter, including the flexible Distal Tip. The Rotator controls the rotational movement of the Distal Tip, independent of the catheter orientation. Rotational movement of the Distal Tip can be achieved either with Wedges deployed or retracted. Luer is provided to facilitate fluid flush and the entry/exit of the guidewire. " DQY Catheter, Percutaneous 2 Wildcat
14 00851354004004 W400 W400 "The Wildcat CTO Catheter is intended to create a channel in totally occluded pe "The Wildcat CTO Catheter is intended to create a channel in totally occluded peripheral vessels. The device may also be used to faciliate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Wildcat Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature. The Wildcat Catheter is intended to be used to support steerable guidewires in accessing discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices. It may also be used to deliver saline or contrast.The Wildcat CTO Catheter is a 6F sheath and 0.035"" guidewire compatible over-the-wire device. It consists of a catheter shaft with a handle assembly at the porximal end and an atraumatic Distal Tip. A locking Luer connector at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only. At the Slider’s most proximal location, the Wedges are in the retracted position. At the mid-point location, the Wedges are deployed. Moving the slider distal from this point initiates deflection of the Distal Tip. The amount of tip deflection increases with distal movement of the slider. At the most distal location, the Wedges remain fully deployed and the Distal Tip is at maximum deflection. The deployment and retraction of the Wedges as well as the deflection of the Distal Tip is visible under fluoroscopic guidance. DQY Catheter, Percutaneous 2 Wildcat
Other products with the same Product Code "CAN"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00812277033717 N6997 N6997 Regulator O2 W/Quick Disconnect Curaplex BOUND TREE MEDICAL, LLC
2 00810050862196 P7202-01-003 PLUS, 66 IN BAY WITH 6 IN CANTILEVER STRUCTURE Patient Loading Utility System (PLUS) LIFEPORT, LLC
3 00810050862127 P6601-30-01-002 PLUS, 66 IN STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
4 00810050862110 P6601-01-055 PLUS, 66 IN STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
5 00810050862080 P6601-28-01-011 PLUS ASSEMBLY, KING AIR 200GT, 66.00 LONG Patient Loading Utility System (PLUS) LIFEPORT, LLC
6 00810050862042 MP2-001-04 ASSEMBLY - MEDPAK * AIR/SUC - 1000W - 115VAC MedPak LIFEPORT, LLC
7 00810050861953 P6601-01-002 PLUS, 66 IN STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
8 00810050861946 P6201-01-011 PLUS, 62 IN SPAR JUMPER STRUCTURE, KING AIR * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
9 00810050861878 P6601-01-091 PLUS, 66 IN STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
10 00810050861816 ST2-271-01-007 16G UTILITY PEDESTAL Utility Pedestal Assembly LIFEPORT, LLC
11 00810050861809 ST2-271-01-004 16G UTILITY PEDESTAL Utility Pedestal Assembly LIFEPORT, LLC
12 00810050861793 P6601-01-074 PLUS, 66 IN STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
13 00810050861786 P7203-01-006 PLUS, 72 IN HIGH G STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
14 00810050861762 P7210-01-005 ASSEMBLY, PLUS, PC-24 Patient Loading Utility System (PLUS) LIFEPORT, LLC
15 00810050861755 P7210-01-004 ASSEMBLY, PLUS, PC-24 Patient Loading Utility System (PLUS) LIFEPORT, LLC
16 00810050861748 PL660-019-13 ASSEMBLY, PLUS Patient Loading and Utility System (PLUS) LIFEPORT, LLC
17 00810050861694 0403-0101-02-08-06 ASSEMBLY - PLUS – MAJOR Patient Loading Utility System (PLUS) LIFEPORT, LLC
18 00810050861687 MP2-001-05 ASSEMBLY – MEDPAK MedPak LIFEPORT, LLC
19 00810050861670 PL660-019-09 ASSEMBLY, PLUS Patient Loading Utility System (PLUS) LIFEPORT, LLC
20 00810050861649 0403-0111-04-01-05 ASSEMBLY - PLUS – MAJOR * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
21 00810050861632 P6601-35-01 ASSEMBLY, PLUS, 4G ROTORCRAFT * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
22 00810050861601 P7203-03-011 PLUS, 72 IN HIGH G STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
23 00810050861595 P7203-01-010 PLUS, 72 IN HIGH G STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
24 00810050861564 P7203-01-001 PLUS, 72 IN HIGH G STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
25 00810050861540 PL480-003-24 ASSEMBLY - PLUS * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
26 00810050861533 0403-0111-04-01-16 ASSEMBLY - PLUS – MAJOR * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
27 00810050861502 P6601-30-01-003 PLUS, 66 IN STRUCTURE * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
28 00810050861489 P7209-02-002 PLUS ASSEMBLY, PC-12/47E * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
29 00810050861472 P7209-01-001 PLUS ASSEMBLY, PC-12/47E * PATIENT LOADING UTILITY SYSTEM Patient Loading Utility System (PLUS) LIFEPORT, LLC
30 00810050861403 366-4300-CF2-02-07 Patient Loading Utility System (PLUS) ASSEMBLY - PLUS LIFEPORT, LLC
31 00810050861397 366-4300-CF2-02-11 ASSEMBLY - PLUS Patient Loading Utility System (PLUS) LIFEPORT, LLC
32 00810050861243 PL720-014-03 ASSEMBLY, PLUS, 72 INCH PLUS LIFEPORT, LLC
33 00810050861236 PL720-014-01 ASSEMBLY, PLUS, 72 INCH PLUS LIFEPORT, LLC
34 00810050861151 P7203-01-011 PLUS, 72 IN HIGH G STRUCTURE PLUS LIFEPORT, LLC
35 00810050861144 P7203-03-010 PLUS, 72 IN HIGH G STRUCTURE PLUS LIFEPORT, LLC
36 00810050861090 P7210-01-002 ASSEMBLY, PLUS, PC-24 PLUS LIFEPORT, LLC
37 00810050861083 P7210-01-001 ASSEMBLY, PLUS, PC-24 PLUS LIFEPORT, LLC
38 00810050861052 PL660-008-19 ASSEMBLY – PLUS PLUS LIFEPORT, LLC
39 00810050860987 PL660-008-03 ASSEMBLY - PLUS PLUS LIFEPORT, LLC
40 00810050860949 PL660-010-37 ASSEMBLY - PLUS - LEAR 45 PLUS LIFEPORT, LLC
41 00810050860901 P6601-17-04-007 PLUS, 66 INCH LONG STRUCTURE PLUS LIFEPORT, LLC
42 00810050860888 PL660-023-29 PLUS ASSEMBLY PLUS LIFEPORT, LLC
43 00810050860802 P6601-28-01-008 PLUS ASSEMBLY, KING AIR 200GT, 66.00 LONG PLUS LIFEPORT, LLC
44 00810050860796 P6601-01-01-002 PLUS, 66 IN LONG, CESSNA 680 PLUS LIFEPORT, LLC
45 00810050860789 P6601-01-01-001 PLUS, 66 IN LONG, CESSNA 680 PLUS LIFEPORT, LLC
46 00810050860772 P6201-01-013 PLUS, 62 IN SPAR JUMPER STRUCTURE, KING AIR PLUS LIFEPORT, LLC
47 00810050860765 PL660-010-27 ASSEMBLY - PLUS - LEAR 45 PLUS LIFEPORT, LLC
48 00810050860703 P6601-18-02-002 PLUS, 66 IN LONG, FALCON 10 PLUS LIFEPORT, LLC
49 00810050860680 P7202-01-004 PLUS, 66 IN BAY WITH 6 IN CANTILEVER STRUCTURE PLUS LIFEPORT, LLC
50 00810050860642 P6601-01-053 PLUS, 66 IN STRUCTURE PLUS LIFEPORT, LLC