Duns Number:003152968
Device Description: "The Ocelot PIXL System consists of the Ocelot PIXL Catheter (“Ocelot PIXL”), the Lightbox "The Ocelot PIXL System consists of the Ocelot PIXL Catheter (“Ocelot PIXL”), the Lightbox console (“Lightbox”), and the Lightbox Umbilical (“Umbilical”). This system combines the use of Avinger’s peripheral catheter designs and an Optical Coherence Tomography (OCT) intravascular orientation and imaging tool. The Ocelot PIXL System is intended to cross chronic total occlusions in the peripheral vasculature while simultaneously providing OCT visualization to help orient the distal tip of the Ocelot PIXL to support the primary intended use. Use of Ocelot PIXL in conjunction with Lightbox allows for OCT imaging as an adjunct to fluoroscopy which facilitates intravascular orientation of the catheter. See Lightbox Operator’s Manual and Umbilical IFU for guidance on setting up and using the Lightbox and Umbilical, respectively. Ocelot PIXL is available in 2 different lengths, 135cm working length and 150cm working length.Ocelot PIXL is an over-the-wire device compatible with a 5F sheath and 0.014” guidewire. It consists of a catheter shaft with handle assembly at the proximal end and a distal tip designed to cross CTOs. A locking luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire (i.e., Lumen Flush Port). The catheter is sterilized by ethylene oxide and is intended for single use only. "
Catalog Number
P135
Brand Name
Ocelot PIXL
Version/Model Number
P135
Device Commercial Distribution Status
In Commercial Distribution
Commercial Distribution End Date
-
Issuing Agency
In GS1
MRI safety Status
Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)
-
Device labeled as "Not made with natural rubber latex"
-
For Single-Use
Yes
Prescription Use (Rx)
Yes
Over the Counter (OTC)
-
Kit
-
Combination Product
-
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)
-
FDA Premarket Submission
K123532
Product Code
PDU
Product Code Name
Catheter For Crossing Total Occlusions
Public Device Record Key
3966087a-a15b-44f0-a3b3-56a80e06d26b
Public Version Date
March 29, 2019
Public Version Number
1
DI Record Publish Date
March 21, 2019
Package DI Number
None
Quantity per Package
-
Contains DI Package
-
Package Discontinue Date
-
Package Status
-
Package Type
-
Device Class | Device Class Description | No of Devices |
---|---|---|
1 | A medical device with low to moderate risk that requires general controls | 2 |