The AXIALIS Ophthalmic Ultrasound System and the probes that are used with it ar
The AXIALIS Ophthalmic Ultrasound System and the probes that are used with it are indicated for diagnostic imaging and biometric measurement of the eye including:• Axial Length measurement of the eye by ultrasonic means.• Implanted IOL power calculation, using the Axial Length measurement.• Measurement of corneal thickness by ultrasonic means.
15 MHz Probe for eye and orbit examination. Automatic biometry readings obtained
15 MHz Probe for eye and orbit examination. Automatic biometry readings obtained from a B mode image allowing axial length measurements for difficult to mesure long eyes or posterior staphyloma.
Digitally programmed S-shaped amplifier characteristics and comprehensive design
Digitally programmed S-shaped amplifier characteristics and comprehensive design criteria for standardized echography and tissue differentiation according to Karl C. Ossoinig MD
Axial length measurement probe with an integrated laser pointer for biometry:- E
Axial length measurement probe with an integrated laser pointer for biometry:- Ensuring the acquisition in the visual axis- Increasing the patient cooperation- Accelerating the speed of acquisition of A scans
50 MHz probe reveals what you can not see with OCT alone, enabling the operator
50 MHz probe reveals what you can not see with OCT alone, enabling the operator to visualize the structures located behind the iris such as ciliary bodies, the processes and lens zonules.Linear scanning offers the greatest signal intensity, providing superior anterior chamber image quality as the probe is always perpendicular with the tissue interface of interest.
10 MHz Probe for eye and orbit examination. Automatic biometry readings obtained
10 MHz Probe for eye and orbit examination. Automatic biometry readings obtained from a B mode image allowing axial length measurements for difficult to mesure long eyes or posterior staphyloma.
10 MHz Probe for eye and orbit examination. Automatic biometry readings obtained
10 MHz Probe for eye and orbit examination. Automatic biometry readings obtained from a B mode image allowing axial length measurements for difficult to mesure long eyes or posterior staphyloma.
Ophthalmic Ultrasound Biometer: Biometry and IOL CalculationThe QUANTEL MEDICAL
Ophthalmic Ultrasound Biometer: Biometry and IOL CalculationThe QUANTEL MEDICAL AXIS NANO Ophthalmic Ultrasound System and the probes that are used with it are indicated for the biometric measurement of the eye including:• Axial Length measurement of the eye by ultrasonic means.• Implanted IOL power calculation, using the Axial Length measurement.
Ophthalmic Ultrasound BiomicroscopeUBM and automatic STS measurement for ICL siz
Ophthalmic Ultrasound BiomicroscopeUBM and automatic STS measurement for ICL sizingThe QUANTEL MEDICAL Compact Touch STS UBMTM Ophthalmic Ultrasound System (and its associated Linear 50 MHz probe) is intended to be used for diagnostic imaging and measurement of the eye including:• Visualization of the interior of the eye by B scans.• Make measurements inside the eye (Sulcus to Sulcus, Irido Cornea Angle Left, Irido Cornea Angle Right, Lens curvature and Anterior Chamber depth).
Ophthalmic Ultrasound System: A/B Scan and PachymetryThe QUANTEL MEDICAL COMPACT
Ophthalmic Ultrasound System: A/B Scan and PachymetryThe QUANTEL MEDICAL COMPACT TOUCH Ophthalmic Ultrasound System and the probes that are used with it are indicated for diagnostic imaging and biometric measurement of the eye including:• Visualization of the interior of the eye and the orbit by A and B scans.• Axial Length measurement of the eye by ultrasonic means.• Implanted IOL power calculation, using the Axial Length measurement.• Measurement of corneal thickness by ultrasonic means.
AVISO (S) Ophthalmic A (A-Std), B Scan and UBM Ultrasound SystemThe QUANTEL MEDI
AVISO (S) Ophthalmic A (A-Std), B Scan and UBM Ultrasound SystemThe QUANTEL MEDICAL AVISO modular platform is an ultrasound system intended to be used for:• Axial Length measurement of the eye by ultrasonic means• Implanted IOL power calculation, using the Axial Length measurement• Visualization of the interior of the eye and the orbit by A and B scans(• Advanced diagnostic: standardized echography provides detailed information about the internal reflectivity of tissues and allows optimal tissues differentiation, localization and measurement of structures in the eye and orbit.)
Universal clamping baseThe steady pro range is intended to reliably maintain the
Universal clamping baseThe steady pro range is intended to reliably maintain the position of a transrectal ultrasound probe during ultra-sound-guided intervention.
Probe holder for transperineal approach.The steady pro range is intended to reli
Probe holder for transperineal approach.The steady pro range is intended to reliably maintain the position of a transrectal ultrasound probe during ultra-sound-guided intervention.
Steady Pro Probe Holding Arm with I and U extension and rail clamping baseThe St
Steady Pro Probe Holding Arm with I and U extension and rail clamping baseThe Steady Pro range is intended to reliably maintain the position of a transrectal ultrasound probe during ultra-sound-guided intervention.
Steady Pro (Mechanical probe holder and supports)The steady pro range is intende
Steady Pro (Mechanical probe holder and supports)The steady pro range is intended to reliably maintain the position of a transrectal ultrasoung probe during untra-sound-guided intervention.
PERINE range guides are made up of one part fixed on the ultrasound probe, which
PERINE range guides are made up of one part fixed on the ultrasound probe, which enables needle guiding. PERINE range guides guide needles of 14 to 20 gauges. The guiding aims to place the needle in the ultrasound image plane.The guides are reusable medical devices.
The guides from PERINE range are intended to guide a needle during ultrasound-g
The guides from PERINE range are intended to guide a needle during ultrasound-guided intervention.PERINE range guides are made up of one part fixed on the ultrasound probe, which enables needle guiding. PERINE range guides guide needles of 14 to 20 gauges. The guiding aims to place the needle in the ultrasound image plane.The guides are reusable medical devices.
The guides from PERINE range are intended to guide a needle during ultrasound-g
The guides from PERINE range are intended to guide a needle during ultrasound-guided intervention.PERINE range guides are made up of one part fixed on the ultrasound probe, which enables needle guiding. PERINE range guides guide needles of 14 to 20 gauges. The guiding aims to place the needle in the ultrasound image plane.The guides are reusable medical devices.
PERINE range guides are made up of one part fixed on the ultrasound probe, which
PERINE range guides are made up of one part fixed on the ultrasound probe, which enables needle guiding. PERINE range guides guide needles of 14 to 20 gauges. The guiding aims to place the needle in the ultrasound image plane.The guides are reusable medical devices.
"PERINE range guides are made up of one part fixed on the ultrasound probe, whic
"PERINE range guides are made up of one part fixed on the ultrasound probe, which enables needle guiding. PERINE range guides guide needles of 14 to 20 gauges. The guiding aims to place the needle in the ultrasound image plane.The guides are reusable medical devices."
PERINE range guides are made up of one part fixed on the ultrasound probe, which
PERINE range guides are made up of one part fixed on the ultrasound probe, which enables needle guiding. PERINE range guides guide needles of 14 to 20 gauges. The guiding aims to place the needle in the ultrasound image plane.The guides are reusable medical devices.
PERINE range guides are made up of one part fixed on the ultrasound probe, which
PERINE range guides are made up of one part fixed on the ultrasound probe, which enables needle guiding. PERINE range guides guide needles of 14 to 20 gauges. The guiding aims to place the needle in the ultrasound image plane.The guides are reusable medical devices."
The device concerned is a metallic guide designed to be plugged on an endocavity
The device concerned is a metallic guide designed to be plugged on an endocavity ultrasound probe, to guide a linear instrument through transrectal access. Sold *5
A mobile workstation composed by a central unit with ultrasound beamformer, a
A mobile workstation composed by a central unit with ultrasound beamformer, a tactile screen, a mouse, a touch pen and a footswitch. All these components are assembled on a mobile cart,Optionally a keyboard can be delivered and a trackball mouse can be delivered instead of the mouse.
The product concerned is a plastic guide designed to be plugged on an endocavity
The product concerned is a plastic guide designed to be plugged on an endocavity ultrasound probe, to guide a linear instrument through transrectal access. The guide is composed of 2 parts welded together to have:• a channel to receive and guide the linear instrument • a clip to allow the guide stability on the transducer • 2 pins for attachment in the notches of the probe• a guide cone to introduce easily the needle into the tube
The PacScan 300 Plus ophthalmic ultrasound system is a non-invasive, active devi
The PacScan 300 Plus ophthalmic ultrasound system is a non-invasive, active device intended for imaging ocular features for diagnostic purposes. The system integrates A-Scan and Pachymeter capabilities into a single system. The A-Scan system allows for measuring the axial length (AXL), anterior chamber depth, and lens thickness of an eye and for calculating the associated IOL power for an implanted lens. The pachymeter is a biometric device that allows for measuring and mapping corneal thickness. The 300A+ A-Scan model can be used to collect scan data using the direct contact or immersion method. There are five examination modes: Cataract, Dense Cataract, Aphakic, Pseudophakic and 4-Gate Manual. The pachymeter uses a higher frequency signal to measure shorter distances. The PacScan 300AP+ system includes a 6" color LCD, touch screen, built-in thermal printer, 10 MHz A-probe, 20 MHz Pachymeter probe, foot switch and operator manual.
The PacScan 300 Plus ophthalmic ultrasound system is a non-invasive, active devi
The PacScan 300 Plus ophthalmic ultrasound system is a non-invasive, active device intended for imaging ocular features for diagnostic purposes. The A-Scan system allows for measuring the axial length (AXL), anterior chamber depth, and lens thickness of an eye and for calculating the associated IOL power for an implanted lens. The 300A+ A-Scan model can be used to collect scan data using the direct contact or immersion method. There are five examination modes: Cataract, Dense Cataract, Aphakic, Pseudophakic and 4-Gate Manual. The PacScan 300A+ system includes a 6" color LCD, touch screen, built-in thermal printer, 10 MHz A-probe, foot switch and operator manual.