Other products from "NEURALYNX, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00850011306406 -D 31-0602-0036 Passive adapter with touchproof inputs and a high density output for adapting 3r Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "D" is labeled for connections to electrodes 193-256. IKD Cable, Electrode 2 High Density Junction Box - D
2 00850011306383 -B 31-0602-0034 Passive adapter with touchproof inputs and a high density output for adapting 3r Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "B" is labeled for connections to electrodes 65-128. IKD Cable, Electrode 2 High Density Junction Box - B
3 10867718000237 ADPT-NKSS-Y-A Adapter Cable 31-0602-0007 The ADPT-NKSS-Y-A is an adapter cable that allows signals from an electrode inte The ADPT-NKSS-Y-A is an adapter cable that allows signals from an electrode interface by Nihon Kohden Corporation to be recorded by both the JE-120A Amplifier by Nihon Kohden Corporation and the JE-212A Amplifier by Nihon Kohden Corporation. IKD Cable, Electrode 2 ADPT-NKSS-Y-A Adapter Cable
4 10850011306281 MEI-PM16 31-0603-0024 Modular Electrode Interface for connecting 16 contact PMT MINI CONNECTOR to Modu Modular Electrode Interface for connecting 16 contact PMT MINI CONNECTOR to Modular Headstage-36 which is connected to the ATLAS Acquisition Amplifier. Modular Electrode Interface-PM16 and Modular Headstage-36 are components of the ATLAS Neurophysiology System. IKD Cable, Electrode 2 Modular Electrode Interface-PM16
5 10850011306229 ATLAS-HS-36-CHET-IDC10 31-0601-0087 The ATLAS-HS-36-CHET-IDC10 is a clinical headstage that allows four X 3M 10 Pin The ATLAS-HS-36-CHET-IDC10 is a clinical headstage that allows four X 3M 10 Pin Receptacle Connector (e.g. 8510-4500PL) connectors to interface with the ATLAS Data Acquisition System. The ATLAS-HS-36-CHET-IDC10 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized. GWL Amplifier, Physiological Signal 2 ATLAS-HS-36-CHET-IDC10
6 10850011306007 ATLAS-HS-36-CHET-TETHER 31-0613-0026 The ATLAS-CHET-36-TETHER is a connection between the ATLAS-HS-36-CHET-X headstag The ATLAS-CHET-36-TETHER is a connection between the ATLAS-HS-36-CHET-X headstage and the ATLAS Neurophysiology System; Note X denotes the type of electrode connection for the CHET, while the TETHER is compatible with multiple CHET-X designs. IKD Cable, Electrode 2 ATLAS-HS-36-CHET-TETHER
7 00850011306413 -E 31-0602-0037 Passive adapter with touchproof inputs and a high density output for adapting 3r Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "E" is labeled for connections to electrodes 257-320. IKD Cable, Electrode 2 High Density Junction Box - E
8 10867718000220 ADPT-NKSS-DRS-BCD Adapter Cable 31-0602-0003 The ADPT-NKSS-DRS-BCD is an adapter that allows signals from an electrode interf The ADPT-NKSS-DRS-BCD is an adapter that allows signals from an electrode interface to be recorded by not only the ATLAS Neurophysiology System (K110967) by Neuralynx, Inc. but also the JE-120A Amplifier (K113117), by Nihon Kohden Corporation. IKD Cable, Electrode 2 ADPT-NKSS-DRS-BCD Adapter Cable
9 10850011306366 -A 31-0602-0032 Passive adapter with touchproof inputs and a high density output for adapting 3r Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "A" is labeled for connections to electrodes 1-64. IKD Cable, Electrode 2 High Density Junction Box
10 10850011306151 ATLAS CHET ADAPTER 31-0602-0028 The ATLAS CHET Adapter is an optional configuration of the ATLAS Neurophysiology The ATLAS CHET Adapter is an optional configuration of the ATLAS Neurophysiology System that allows up to 4 clinical headstages to interface with the ATLAS Acquisition Amplifier. IKD Cable, Electrode 2 ATLAS CHET ADAPTER
11 10850011306090 EXTENSION CABLE: TETH-XTN-5 Meter 31-0613-0004 The TETH-XTN-MM-5 is a component of the ATLAS Neurophysiology System IKD Cable, Electrode 2 TETH-XTN-MM-5
12 10850011306076 EXTENSION CABLE: TETH-XTN-1 Meter 31-0613-0002 The TETH-XTN-MM-1 is a component of the ATLAS Neurophysiology System IKD Cable, Electrode 2 TETH-XTN-MM-1
13 00850011306505 5.38 m 31-0202-0005 Flexible cable to connect the High Density Junction Box to the ATLAS Neurophysio Flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System. IKD Cable, Electrode 2 High Density Tether 5.38 m
14 00850011306024 1.0 HS-10-CHET-A 1.0 The HS-10-CHET-A 1.0 is a clinical headstage that allows one Ad-Tech Tail Electr The HS-10-CHET-A 1.0 is a clinical headstage that allows one Ad-Tech Tail Electrode (usually consisting of up to 9 electrodes) to interface with the ATLAS Neurophysiology System. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS-HS-10-CHET-A 1.0
15 10867718000206 ATLAS TPSS Cable 31-0602-0027 The ATLAS TPSS Cable is an adapter that allows signals from an electrode interfa The ATLAS TPSS Cable is an adapter that allows signals from an electrode interface to be recorded by not only the ATLAS Neurophysiology System by Neuralynx, Inc. but also other neurophysiology recording systems with touch proof connectors. The ATLAS TPSS Cable shares the outputs from the electrode interface and splits them to both systems to be digitized. IKD Cable, Electrode 2 ATLAS TPSS Cable
16 10850011306106 EXTENSION CABLE: TETH-XTN-8 Meter 31-0613-0005 The TETH-XTN-MM-8 is a component of the ATLAS Neurophysiology System IKD Cable, Electrode 2 TETH-XTN-MM-8
17 10850011306137 Modular Headstage-36 31-0601-0091 The Modular Headstage-36 is a clinical headstage that connects to one of several The Modular Headstage-36 is a clinical headstage that connects to one of several modular electrode interfaces to connect electrodes from various manufacturers to the ATLAS Neurophysiology System. The Modular Headstage-36 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized. OMC Reduced- Montage Standard Electroencephalograph 2 Modular Headstage-36
18 10850011306069 ATLAS NK HEADBOX 31-0601-0017 The ATLAS NK Headbox allows JE-125A, JE-225A, JE-226A, JE-227A, and JE-228A Mini The ATLAS NK Headbox allows JE-125A, JE-225A, JE-226A, JE-227A, and JE-228A Mini Flat Junction Boxes by Nihon Kohden Corporation (NKC) to interface with the ATLAS Neurophysiology System by Neuralynx and JE-120A or JE-212A Amplifier by Nihon Kohden Corporation through the ATLAS NKSS Cable (also by Neuralynx). OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS NK HEADBOX
19 10850011306045 ATLAS HEADBOX 31-0601-0007 The ATLAS Headbox is a clinical headbox that allows ECoG electrodes with 1.5mm T The ATLAS Headbox is a clinical headbox that allows ECoG electrodes with 1.5mm Touch-Proof Connector Adapters to interface with the ATLAS Neurophysiology System. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS HEADBOX
20 00850011306437 -G 31-0602-0039 Passive adapter with touchproof inputs and a high density output for adapting 3r Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "G" is labeled for connections to electrodes 385-448. IKD Cable, Electrode 2 High Density Junction Box - G
21 00850011306390 -C 31-0602-0035 Passive adapter with touchproof inputs and a high density output for adapting 3r Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "C" is labeled for connections to electrodes 129-192. IKD Cable, Electrode 2 High Density Junction Box - C
22 10867718000299 ATLAS-HS-36-CHET-D18 31-0601-0082 The ATLAS-HS-36-CHET-D18 is a clinical headstage that allows two 18 contact DIXI The ATLAS-HS-36-CHET-D18 is a clinical headstage that allows two 18 contact DIXI electrode connectors to interface with the ATLAS Data Acquisition System. The ATLAS-HS-36-CHET-D18 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized. GWL Amplifier, Physiological Signal 2 ATLAS-HS-36-CHET-D18
23 10867718000275 2.1.0 Pegasus Pegasus is the software component of the ATLAS Neurophysiology System that inter Pegasus is the software component of the ATLAS Neurophysiology System that interfaces with the amplifier. It is used to display, store and archive EEG signals and allow user-only annotation and marking. Pegasus does not analyze EEG or automatically detect events. OMC Reduced- Montage Standard Electroencephalograph 2 Pegasus
24 10850011306359 ATLAS HD HEADBOX 31-0601-0131 The ATLAS HD Headbox is a clinical headbox that allows electrode connections end The ATLAS HD Headbox is a clinical headbox that allows electrode connections ending in an MDR-68 connector to interface with the ATLAS Neurophysiology System. The ATLAS HD Headbox allows two MDR-68 connectors to be tied in parallel and a switch to disable active driven ground supplied by the ATLAS Neurophysiology system. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS HD HEADBOX
25 10850011306274 MEI-PM10 31-0603-0022 Modular Electrode Interface for connecting 10 contact PMT MINI CONNECTOR to Modu Modular Electrode Interface for connecting 10 contact PMT MINI CONNECTOR to Modular Headstage-36 which is connected to the ATLAS Acquisition Amplifier. Modular Electrode Interface-PM10 and Modular Headstage-36 are components of the ATLAS Neurophysiology System. IKD Cable, Electrode 2 Modular Electrode Interface-PM10
26 10850011306243 ATLAS MICROMED JB INTERFACE 31-0601-0088 The ATLAS MICROMED JB INTERFACE is a buffered interface between Micromed Jackbox The ATLAS MICROMED JB INTERFACE is a buffered interface between Micromed Jackbox and ATLAS. The ATLAS MICROMED JB INTERFACE uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized. GWL Amplifier, Physiological Signal 2 ATLAS MICROMED JB INTERFACE
27 10850011306083 EXTENSION CABLE: TETH-XTN-2 Meter 31-0613-0003 The TETH-XTN-MM-2 is a component of the ATLAS Neurophysiology System IKD Cable, Electrode 2 TETH-XTN-MM-2
28 00850011306192 ATLAS Patient Event Marker Patient Event Marker The ATLAS Patient Event Marker is an optional configuration of the ATLAS Neuroph The ATLAS Patient Event Marker is an optional configuration of the ATLAS Neurophysiology System that allows the patient to mark an event in the Data Acquisition Software. IKD Cable, Electrode 2 ATLAS Patient Event Marker
29 00850011306031 1.0 HS-18-CHET-A 1.0 The HS-18-CHET-A 1.0 is a clinical headstage that allows one Ad-Tech Tail Electr The HS-18-CHET-A 1.0 is a clinical headstage that allows one Ad-Tech Tail Electrode (usually consisting of up to 16 electrodes) to interface with the ATLAS Neurophysiology System. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS-HS-18-CHET-A 1.0
30 10867718000244 ADPT-NKSS-Y-B Adapter Cable 31-0602-0008 The ADPT-NKSS-Y-B is an adapter cable that allows signals from an electrode inte The ADPT-NKSS-Y-B is an adapter cable that allows signals from an electrode interface by Nihon Kohden Corporation to be recorded by both the JE-120A Amplifier by Nihon Kohden Corporation and the JE-212A Amplifier by Nihon Kohden Corporation. IKD Cable, Electrode 2 ADPT-NKSS-Y-B Adapter Cable
31 10850011306373 High Density Tether 31-0202-0001 The High Density Tether is a flexible cable to connect the High Density Junction The High Density Tether is a flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System. The High Density Tether is a component of the ATLAS Neurophysiology System. IKD Cable, Electrode 2 High Density Tether
32 00850011306482 ATLAS Cart 31-0605-0116 Accessory designed for use with the ATLAS Neurophysiology System and its accessories. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS Cart
33 00850011306451 1m 31-0202-0002 The High Density Tether is a flexible cable to connect the High Density Junction The High Density Tether is a flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System. The High Density Tether is a component of the ATLAS Neurophysiology System. IKD Cable, Electrode 2 High Density Tether 1m
34 00850011306185 Active Ground Drive 31-0604-0100 The Active Ground Drive generates the Active Ground signal based on input select The Active Ground Drive generates the Active Ground signal based on input selected in the Data Acquisition Software. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS Ground Drive
35 10867718000268 ATLAS Neurophysiology System ATLAS Neurophysiology System Electroencephalographic monitoring system, stationary OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS Neurophysiology System
36 10867718000251 ADPT-NKSS-Y-C Adapter Cable 31-0602-0009 The ADPT-NKSS-Y-C is an adapter cable that allows signals from an electrode inte The ADPT-NKSS-Y-C is an adapter cable that allows signals from an electrode interface by Nihon Kohden Corporation to be recorded by both the JE-120A Amplifier by Nihon Kohden Corporation and the JE-212A Amplifier by Nihon Kohden Corporation. IKD Cable, Electrode 2 ADPT-NKSS-Y-C Adapter Cable
37 10850011306212 ATLAS-HS-36-CHET-A9 31-0601-0086 The ATLAS-HS-36-CHET-A9 is a clinical headstage that allows four X 9 contact Adt The ATLAS-HS-36-CHET-A9 is a clinical headstage that allows four X 9 contact Adtech electrode connectors to interface with the ATLAS Data Acquisition System. The ATLAS-HS-36-CHET-A9 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized. GWL Amplifier, Physiological Signal 2 ATLAS-HS-36-CHET-A9
38 10850011306205 ATLAS TOPHAT Adapter Cable 31-0602-0010 The ATLAS TOPHAT Adapter cable allows signals from a Micromed JB TOPHAT electrod The ATLAS TOPHAT Adapter cable allows signals from a Micromed JB TOPHAT electrode interface to be recorded by the ATLAS Neurophysiology System. IKD Cable, Electrode 2 ATLAS TOPHAT Adapter Cable
39 10850011306144 ATLAS COMBO BOARD 31-0605-0117 The ATLAS Combo Board combines the functionality of the ATLAS Hybrid Input Board The ATLAS Combo Board combines the functionality of the ATLAS Hybrid Input Board and ATLAS DRS-36 Board onto a single board, meaning the Digital Reference Selection and Analog to Digital Conversion for 32 electrodes is combined into a single slot. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS COMBO BOARD
40 10850011306120 TETHER INTERCONNECT 31-0602-0004 The TETHER INTERCONNECT is a component of the ATLAS Neurophysiology System. IKD Cable, Electrode 2 TETHER INTERCONNECT
41 00850011306475 3m The High Density Tether is a flexible cable to connect the High Density Junction The High Density Tether is a flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System. The High Density Tether is a component of the ATLAS Neurophysiology System. IKD Cable, Electrode 2 High Density Tether 3m
42 00850011306420 -F 31-0602-0038 Passive adapter with touchproof inputs and a high density output for adapting 3r Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "F" is labeled for connections to electrodes 321-384. IKD Cable, Electrode 2 High Density Junction Box - F
43 00850011306178 ATLAS TTL Isolator 31-0604-0060 The ATLAS TTL Isolator is an optional configuration of the ATLAS Neurophysiology The ATLAS TTL Isolator is an optional configuration of the ATLAS Neurophysiology System that isolates two of the four 8 bit TTL Ports on the front of the system. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS TTL Isolator
44 00850011306499 31-0602-0033 ADPT-HD-Y Adapter Cable for use with the ATLAS Neurophysiology System. IKD Cable, Electrode 2 ADPT-HD-Y Adapter Cable
45 00850011306468 2m 31-0202-0003 The High Density Tether is a flexible cable to connect the High Density Junction The High Density Tether is a flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System. The High Density Tether is a component of the ATLAS Neurophysiology System. IKD Cable, Electrode 2 High Density Tether 2m
46 10867718000213 ADPT-NKSS-DRS-A AdapterCable 31-0602-0002 The ADPT-NKSS-DRS-A is an adapter cable that allows signals from an electrode in The ADPT-NKSS-DRS-A is an adapter cable that allows signals from an electrode interface to be recorded by not only the ATLAS Neurophysiology System (K110967) by Neuralynx, Inc. but also the JE-120A Amplifier (K113117), by Nihon Kohden Corporation. IKD Cable, Electrode 2 ADPT-NKSS-DRS-A AdapterCable
47 10850011306328 ATLAS HDSS 31-0602-0031 The ATLAS High Density Signal Splitter (HDSS) is an adapter that allows signals The ATLAS High Density Signal Splitter (HDSS) is an adapter that allows signals from an electrode interface to be recorded by not only the ATLAS Neurophysiological System (K110967) by Neuralynx, Inc. but also the Quantum Amplifier by Natus Corporation. The ATLAS HDSS shares the buffered outputs from the electrode interface and routes them to both systems to be digitized. IKD Cable, Electrode 2 ATLAS HDSS
48 10850011306168 ATLAS ANALOG ISOLATOR 31-0602-0029 The ATLAS Analog Isolator is an optional accessory of the ATLAS Neurophysiology The ATLAS Analog Isolator is an optional accessory of the ATLAS Neurophysiology System that isolates 16 analog channels on the system. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS ANALOG ISOLATOR
49 10850011306052 ATLAS HC HEADBOX 31-0601-0010 The ATLAS HC Headbox is a clinical headbox that allows a CA-105 waveguard™ EEG C The ATLAS HC Headbox is a clinical headbox that allows a CA-105 waveguard™ EEG Cap by ANT Neuro to interface with the ATLAS Neurophysiology System by Neuralynx. OMC Reduced- Montage Standard Electroencephalograph 2 ATLAS HC HEADBOX
Other products with the same Product Code "IKD"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10885672102491 ATAR D-MDT2 ATAR D-MDT2 Disposable Extension Cable ATAR D-MDT2 OSCOR INC.
2 10885672102514 ATAR D-MDTR ATAR D-MDTR Disposable Extension Cable ATAR D-MDTR OSCOR INC.
3 10885672102507 ATAR D-MDT3 ATAR D-MDT3 Disposable Extension Cable ATAR D-MDT3 OSCOR INC.
4 10885672102590 ATAR D-T2 ATAR D-T2 Disposable Extension Cable ATAR D-T2 OSCOR INC.
5 10885672102583 ATAR D-V2 ATAR D-V2 Disposable Extension Cable ATAR D-V2 OSCOR INC.
6 10885672102576 ATAR D-R X2L ATAR D-R X2L Disposable Extension Cable ATAR D-R X2L OSCOR INC.
7 10885672102569 ATAR D-R X2 ATAR D-R X2 Disposable Extension Cable ATAR D-R X2 OSCOR INC.
8 10885672102552 ATAR D-R T4P ATAR D-R T4P Disposable Extension Cable ATAR D-R T4P OSCOR INC.
9 10885672102545 ATAR D-R T2P ATAR D-R T2P Disposable Extension Cable ATAR D-R T2P OSCOR INC.
10 10885672102538 ATAR D-R D2P ATAR D-R D2P Disposable Extension Cable ATAR D-R D2P OSCOR INC.
11 10885672102521 ATAR D-R1 ATAR D-R1 Disposable Extension Cable ATAR D-R1 OSCOR INC.
12 10885672102484 ATAR D-R NP ATAR D-R NP Disposable Extension Cable ATAR D-R NP OSCOR INC.
13 10885672101944 ATAR D-MDTS ATAR D-MDTS Disposable Extension Cable ATAR D-MDTS OSCOR INC.
14 10885672010048 53912D 53912D Disposable Extension Cable 53912D Disposable Extension Cable OSCOR INC.
15 10885672009639 XI.D-RL XI.D-RL Disposable Extension Cable XI.D-RL™ OSCOR INC.
16 10885672009622 XI.D-T XI.D-T Disposable Extension Cable XI.D-T™ OSCOR INC.
17 10885672009615 XI.D-MDT XI.D-MDT Disposable Extension Cable XI.D-MDT™ OSCOR INC.
18 10885672009608 XI.D-V XI.D-V Disposable Extension Cable XI.D-V™ OSCOR INC.
19 10885672009592 XI.D-A XI.D-A Disposable Extension Cable XI.D-A™ OSCOR INC.
20 10885672008793 ATAR D-MDT2S-V ATAR D-MDT2S-V Disposable Extension Cable ATAR D-MDT2S-V OSCOR INC.
21 10885672008786 ATAR D-MDT2S-A ATAR D-MDT2S-A Disposable Extension Cable ATAR D-MDT2S-A OSCOR INC.
22 10885403256615 2016560-003 2016560-003 Cable for CAM14, for MAC5500 , 4.6m / 15ft N/A CAREFUSION FINLAND 320 OY
23 10885403256608 2016560-002 2016560-002 Cable for CAM14, for CASE , 4.6m / 15ft N/A CAREFUSION FINLAND 320 OY
24 10885403256592 2016560-001 2016560-001 Cable for CAM14, for MAC5500 , 1.3m / 4.2ft N/A CAREFUSION FINLAND 320 OY
25 10885380181061 50000331 50000331 Fetal Spiral Electrode Cable Kendall CARDINAL HEALTH 200, LLC
26 10885380181054 50000107 50000107 Fetal Spiral Electrode Cable Kendall CARDINAL HEALTH 200, LLC
27 10885380181047 31479846 31479846 Fetal Spiral Electrode Cable Kendall CARDINAL HEALTH 200, LLC
28 10885380181030 31479812 31479812 Fetal Spiral Electrode Cable Kendall CARDINAL HEALTH 200, LLC
29 10885380181023 31479754 31479754 Fetal Spiral Electrode Cable Kendall CARDINAL HEALTH 200, LLC
30 10885380178306 33549 33549 Kendall DL Adapter, 3-Lead, For Nihon Kohden Monitors, Bedside, Reusable Kendall CARDINAL HEALTH, INC.
31 10885380177460 None 33554 Kendall DL Adapter, 10-Lead, For Drager M540 Monitors Kendall CARDINAL HEALTH, INC.
32 10885380177453 None 33553 Kendall DL Adapter, 3-5-6 Lead, For Drager Monitors, OR, Bedside Kendall CARDINAL HEALTH, INC.
33 10885380177446 None 33552 Kendall DL Adapter, 3-5-6 Lead, For Drager Monitors, Bedside Kendall CARDINAL HEALTH, INC.
34 10885380175015 None 33153T Kendall DL ECG Dual Connect Lead Wires, 6-Lead, 36", Single Patient Use Kendall CARDINAL HEALTH 200, LLC
35 10885380175008 33154T 33154T Kendall DL ECG Dual Connect Cable and Lead Wire System, 6-Lead, 144", Single Patient Use Kendall CARDINAL HEALTH, INC.
36 10885380166211 33551 33551 Kendall DL Adapter, 3 or 5 Lead for Draeger 6 pin, part number: 33551 Kendall CARDINAL HEALTH, INC.
37 10884527022144 MW72130 MW72130 Adapters,Y-Cable Uni-Patch CARDINAL HEALTH, INC.
38 10884527022113 33534 33534- True content to be populated as part of rebranding Kendall CARDINAL HEALTH, INC.
39 10884527022106 33533 33533- True content to be populated as part of rebranding Kendall CARDINAL HEALTH, INC.
40 10884527022090 33532 33532 True content to be populated as part of rebranding Kendall CARDINAL HEALTH, INC.
41 10884527022083 33531 33531 True content to be populated as part of rebranding Kendall CARDINAL HEALTH, INC.
42 10884527022069 33530 33530 True content to be populated as part of rebranding Kendall CARDINAL HEALTH, INC.
43 10884527022045 33529 33529- True content to be populated as part of rebranding Kendall CARDINAL HEALTH, INC.
44 10884527022038 33144 33144 DL Disposable Lead,Telemetry Single Lead Kendall CARDINAL HEALTH, INC.
45 10884527021505 33510 33510 DL 17 Pin Adapter,3 Lead Kendall CARDINAL HEALTH, INC.
46 10884527021499 33509 33509 DL 17 Pin Adapter,5 Lead Kendall CARDINAL HEALTH, INC.
47 10884527021482 33508 33508 DL 8 Pin Adapter,3/5 Lead Kendall CARDINAL HEALTH, INC.
48 10884527021475 33507 33507 DL 12 Pin Adapter,3/5 Lead Kendall CARDINAL HEALTH, INC.
49 10884527021468 33506 33506 DL 11 Pin Adapter,5 Lead Kendall CARDINAL HEALTH, INC.
50 10884527021451 33505 33505 DL 11 Pin Adapter,12 Lead Kendall CARDINAL HEALTH, INC.