Passive adapter with touchproof inputs and a high density output for adapting 3r
Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "D" is labeled for connections to electrodes 193-256.
The ADPT-NKSS-Y-A is an adapter cable that allows signals from an electrode inte
The ADPT-NKSS-Y-A is an adapter cable that allows signals from an electrode interface by Nihon Kohden Corporation to be recorded by both the JE-120A Amplifier by Nihon Kohden Corporation and the JE-212A Amplifier by Nihon Kohden Corporation.
Modular Electrode Interface for connecting 16 contact PMT MINI CONNECTOR to Modu
Modular Electrode Interface for connecting 16 contact PMT MINI CONNECTOR to Modular Headstage-36 which is connected to the ATLAS Acquisition Amplifier. Modular Electrode Interface-PM16 and Modular Headstage-36 are components of the ATLAS Neurophysiology System.
The ATLAS-HS-36-CHET-IDC10 is a clinical headstage that allows four X 3M 10 Pin
The ATLAS-HS-36-CHET-IDC10 is a clinical headstage that allows four X 3M 10 Pin Receptacle Connector (e.g. 8510-4500PL) connectors to interface with the ATLAS Data Acquisition System. The ATLAS-HS-36-CHET-IDC10 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized.
The ATLAS-CHET-36-TETHER is a connection between the ATLAS-HS-36-CHET-X headstag
The ATLAS-CHET-36-TETHER is a connection between the ATLAS-HS-36-CHET-X headstage and the ATLAS Neurophysiology System; Note X denotes the type of electrode connection for the CHET, while the TETHER is compatible with multiple CHET-X designs.
Passive adapter with touchproof inputs and a high density output for adapting 3r
Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "E" is labeled for connections to electrodes 257-320.
The ADPT-NKSS-DRS-BCD is an adapter that allows signals from an electrode interf
The ADPT-NKSS-DRS-BCD is an adapter that allows signals from an electrode interface to be recorded by not only the ATLAS Neurophysiology System (K110967) by Neuralynx, Inc. but also the JE-120A Amplifier (K113117), by Nihon Kohden Corporation.
Passive adapter with touchproof inputs and a high density output for adapting 3r
Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "A" is labeled for connections to electrodes 1-64.
The ATLAS CHET Adapter is an optional configuration of the ATLAS Neurophysiology
The ATLAS CHET Adapter is an optional configuration of the ATLAS Neurophysiology System that allows up to 4 clinical headstages to interface with the ATLAS Acquisition Amplifier.
Flexible cable to connect the High Density Junction Box to the ATLAS Neurophysio
Flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System.
The HS-10-CHET-A 1.0 is a clinical headstage that allows one Ad-Tech Tail Electr
The HS-10-CHET-A 1.0 is a clinical headstage that allows one Ad-Tech Tail Electrode (usually consisting of up to 9 electrodes) to interface with the ATLAS Neurophysiology System.
The ATLAS TPSS Cable is an adapter that allows signals from an electrode interfa
The ATLAS TPSS Cable is an adapter that allows signals from an electrode interface to be recorded by not only the ATLAS Neurophysiology System by Neuralynx, Inc. but also other neurophysiology recording systems with touch proof connectors. The ATLAS TPSS Cable shares the outputs from the electrode interface and splits them to both systems to be digitized.
The Modular Headstage-36 is a clinical headstage that connects to one of several
The Modular Headstage-36 is a clinical headstage that connects to one of several modular electrode interfaces to connect electrodes from various manufacturers to the ATLAS Neurophysiology System. The Modular Headstage-36 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized.
The ATLAS NK Headbox allows JE-125A, JE-225A, JE-226A, JE-227A, and JE-228A Mini
The ATLAS NK Headbox allows JE-125A, JE-225A, JE-226A, JE-227A, and JE-228A Mini Flat Junction Boxes by Nihon Kohden Corporation (NKC) to interface with the ATLAS Neurophysiology System by Neuralynx and JE-120A or JE-212A Amplifier by Nihon Kohden Corporation through the ATLAS NKSS Cable (also by Neuralynx).
The ATLAS Headbox is a clinical headbox that allows ECoG electrodes with 1.5mm T
The ATLAS Headbox is a clinical headbox that allows ECoG electrodes with 1.5mm Touch-Proof Connector Adapters to interface with the ATLAS Neurophysiology System.
Passive adapter with touchproof inputs and a high density output for adapting 3r
Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "H" is labeled for connections to electrodes 449-512.
Passive adapter with touchproof inputs and a high density output for adapting 3r
Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "G" is labeled for connections to electrodes 385-448.
Passive adapter with touchproof inputs and a high density output for adapting 3r
Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "C" is labeled for connections to electrodes 129-192.
The ATLAS-HS-36-CHET-D18 is a clinical headstage that allows two 18 contact DIXI
The ATLAS-HS-36-CHET-D18 is a clinical headstage that allows two 18 contact DIXI electrode connectors to interface with the ATLAS Data Acquisition System. The ATLAS-HS-36-CHET-D18 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized.
Pegasus is the software component of the ATLAS Neurophysiology System that inter
Pegasus is the software component of the ATLAS Neurophysiology System that interfaces with the amplifier. It is used to display, store and archive EEG signals and allow user-only annotation and marking. Pegasus does not analyze EEG or automatically detect events.
The ATLAS HD Headbox is a clinical headbox that allows electrode connections end
The ATLAS HD Headbox is a clinical headbox that allows electrode connections ending in an MDR-68 connector to interface with the ATLAS Neurophysiology System. The ATLAS HD Headbox allows two MDR-68 connectors to be tied in parallel and a switch to disable active driven ground supplied by the ATLAS Neurophysiology system.
Modular Electrode Interface for connecting 10 contact PMT MINI CONNECTOR to Modu
Modular Electrode Interface for connecting 10 contact PMT MINI CONNECTOR to Modular Headstage-36 which is connected to the ATLAS Acquisition Amplifier. Modular Electrode Interface-PM10 and Modular Headstage-36 are components of the ATLAS Neurophysiology System.
The ATLAS MICROMED JB INTERFACE is a buffered interface between Micromed Jackbox
The ATLAS MICROMED JB INTERFACE is a buffered interface between Micromed Jackbox and ATLAS. The ATLAS MICROMED JB INTERFACE uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized.
The ATLAS Patient Event Marker is an optional configuration of the ATLAS Neuroph
The ATLAS Patient Event Marker is an optional configuration of the ATLAS Neurophysiology System that allows the patient to mark an event in the Data Acquisition Software.
The HS-18-CHET-A 1.0 is a clinical headstage that allows one Ad-Tech Tail Electr
The HS-18-CHET-A 1.0 is a clinical headstage that allows one Ad-Tech Tail Electrode (usually consisting of up to 16 electrodes) to interface with the ATLAS Neurophysiology System.
The ADPT-NKSS-Y-B is an adapter cable that allows signals from an electrode inte
The ADPT-NKSS-Y-B is an adapter cable that allows signals from an electrode interface by Nihon Kohden Corporation to be recorded by both the JE-120A Amplifier by Nihon Kohden Corporation and the JE-212A Amplifier by Nihon Kohden Corporation.
The High Density Tether is a flexible cable to connect the High Density Junction
The High Density Tether is a flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System. The High Density Tether is a component of the ATLAS Neurophysiology System.
The High Density Tether is a flexible cable to connect the High Density Junction
The High Density Tether is a flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System. The High Density Tether is a component of the ATLAS Neurophysiology System.
The Active Ground Drive generates the Active Ground signal based on input select
The Active Ground Drive generates the Active Ground signal based on input selected in the Data Acquisition Software.
The ADPT-NKSS-Y-C is an adapter cable that allows signals from an electrode inte
The ADPT-NKSS-Y-C is an adapter cable that allows signals from an electrode interface by Nihon Kohden Corporation to be recorded by both the JE-120A Amplifier by Nihon Kohden Corporation and the JE-212A Amplifier by Nihon Kohden Corporation.
The ATLAS-HS-36-CHET-A9 is a clinical headstage that allows four X 9 contact Adt
The ATLAS-HS-36-CHET-A9 is a clinical headstage that allows four X 9 contact Adtech electrode connectors to interface with the ATLAS Data Acquisition System. The ATLAS-HS-36-CHET-A9 uses electronic components to buffer single unit activity sensed by the electrodes and sends it to the ATLAS Data Acquisition System to be digitized.
The ATLAS TOPHAT Adapter cable allows signals from a Micromed JB TOPHAT electrod
The ATLAS TOPHAT Adapter cable allows signals from a Micromed JB TOPHAT electrode interface to be recorded by the ATLAS Neurophysiology System.
The ATLAS Combo Board combines the functionality of the ATLAS Hybrid Input Board
The ATLAS Combo Board combines the functionality of the ATLAS Hybrid Input Board and ATLAS DRS-36 Board onto a single board, meaning the Digital Reference Selection and Analog to Digital Conversion for 32 electrodes is combined into a single slot.
The High Density Tether is a flexible cable to connect the High Density Junction
The High Density Tether is a flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System. The High Density Tether is a component of the ATLAS Neurophysiology System.
Passive adapter with touchproof inputs and a high density output for adapting 3r
Passive adapter with touchproof inputs and a high density output for adapting 3rd party electrode interface cables to the ATLAS Neurophysiology System. Version "F" is labeled for connections to electrodes 321-384.
The ATLAS TTL Isolator is an optional configuration of the ATLAS Neurophysiology
The ATLAS TTL Isolator is an optional configuration of the ATLAS Neurophysiology System that isolates two of the four 8 bit TTL Ports on the front of the system.
The High Density Tether is a flexible cable to connect the High Density Junction
The High Density Tether is a flexible cable to connect the High Density Junction Box to the ATLAS Neurophysiology System. The High Density Tether is a component of the ATLAS Neurophysiology System.
The ADPT-NKSS-DRS-A is an adapter cable that allows signals from an electrode in
The ADPT-NKSS-DRS-A is an adapter cable that allows signals from an electrode interface to be recorded by not only the ATLAS Neurophysiology System (K110967) by Neuralynx, Inc. but also the JE-120A Amplifier (K113117), by Nihon Kohden Corporation.
The ATLAS High Density Signal Splitter (HDSS) is an adapter that allows signals
The ATLAS High Density Signal Splitter (HDSS) is an adapter that allows signals from an electrode interface to be recorded by not only the ATLAS Neurophysiological System (K110967) by Neuralynx, Inc. but also the Quantum Amplifier by Natus Corporation. The ATLAS HDSS shares the buffered outputs from the electrode interface and routes them to both systems to be digitized.
The ATLAS Analog Isolator is an optional accessory of the ATLAS Neurophysiology
The ATLAS Analog Isolator is an optional accessory of the ATLAS Neurophysiology System that isolates 16 analog channels on the system.
The ATLAS HC Headbox is a clinical headbox that allows a CA-105 waveguard™ EEG C
The ATLAS HC Headbox is a clinical headbox that allows a CA-105 waveguard™ EEG Cap by ANT Neuro to interface with the ATLAS Neurophysiology System by Neuralynx.