Other products from "ADVANCE MEDICAL DESIGNS, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00848340002434 07-CA200 C-Arm JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
2 00848340002427 07-CA400 C-Arm JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
3 00848340002380 01-0512T Snap Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
4 00848340000928 09-MK3936 Micro Cover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
5 00848340000911 09-GL903 Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
6 00848340002274 SYN-0501 Synaptive Patch Drape JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
7 00848340002205 05-SD939 Disposable Equipment Cover JAA System, x-ray, fluoroscopic, image-intensified 2 Shea Drill Drape
8 00848340002182 05-DD3948 Disposable Equipment Cover JAA System, x-ray, fluoroscopic, image-intensified 2 Drill Drape
9 00848340002175 05-CD2720 Console Drape JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
10 00848340000904 09-GL902 Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
11 00848340000898 09-GL901S Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
12 00848340002168 08-CC167-A Urologic Drain Bag KKX Drape, surgical 2 UNBRANDED
13 00848340002151 08-CC167 Urologic Drain Bag KKX Drape, surgical 2 UNBRANDED
14 00848340002144 08-CC165 Urologic Drain Bag KKX Drape, surgical 2 UNBRANDED
15 00848340002137 07-PK806 UroView System Pack KKX Drape, surgical 2 UNBRANDED
16 00848340002120 08-CC160-UB Urologic Drain Bag KKX Drape, surgical 2 UNBRANDED
17 00848340002113 08-CC160 Urologic Drain Bag KKX Drape, surgical 2 UNBRANDED
18 00848340000881 09-GL901 Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
19 00848340002106 07-PK805-UB UroView System Pack KKX Drape, surgical 2 UNBRANDED
20 00848340002090 07-PK805 UroView System Pack KKX Drape, surgical 2 UNBRANDED
21 00848340002076 30-CS01 Control Syringe FMF Syringe, piston 2 UNBRANDED
22 00848340002069 72-CFS02 Closed Fluid Set FPA Set, administration, intravascular 2 UNBRANDED
23 00848340002052 72-CFS01 Closed Fluid Set FPA Set, administration, intravascular 2 UNBRANDED
24 00848340002045 5490C Set-up Cover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
25 00848340002038 5470C Set-up Cover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
26 00848340002021 5454C Set-up Cover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
27 00848340002014 2019 Soft Pressure Dressing FRO Dressing, wound, drug U UNBRANDED
28 00848340000874 09-GL900 Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
29 00848340002007 2018 Arterial Pressure Dressing FRO Dressing, wound, drug U UNBRANDED
30 00848340001994 07-KC08 Knob Cover HRM MICROSCOPE, OPERATING & ACCESSORIES, AC-POWERED, OPHTHALMIC 1 UNBRANDED
31 00848340001987 07-KC06 Knob Cover HRM MICROSCOPE, OPERATING & ACCESSORIES, AC-POWERED, OPHTHALMIC 1 UNBRANDED
32 00848340001970 07-KC04 Knob Cover HRM MICROSCOPE, OPERATING & ACCESSORIES, AC-POWERED, OPHTHALMIC 1 UNBRANDED
33 00848340001963 07-KC02 Knob Cover HRM MICROSCOPE, OPERATING & ACCESSORIES, AC-POWERED, OPHTHALMIC 1 UNBRANDED
34 00848340001956 60-HP48R High Pressure line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
35 00848340001949 60-HP48 High Pressure line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
36 00848340001932 60-HP30R High Pressure line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
37 00848340001925 60-HP30 High Pressure line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
38 00848340001918 60-HP20R High Pressure line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
39 00848340001901 60-HP20 High Pressure line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
40 00848340001895 60-HP10R High Pressure line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
41 00848340001888 60-HP10 High Pressure line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
42 00848340001871 63-PM96M Pressure Monitoring line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
43 00848340000867 09-GL804A Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
44 00848340000850 09-GL802 Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
45 00848340001864 63-PM84M Pressure Monitoring line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
46 00848340001857 63-PM72M Pressure Monitoring line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
47 00848340001840 63-PM60M Pressure Monitoring line DTL Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass 2 UNBRANDED
48 00848340000843 09-GL801 Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
49 00848340000836 09-GL800 Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
50 00848340000829 09-MK945 Micro Kover JAA System, x-ray, fluoroscopic, image-intensified 2 UNBRANDED
Other products with the same Product Code "JAA"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00195451000416 12.0x30mm L6IVL120030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
2 00195451000409 10.0x30mm L6IVL100030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
3 00195451000393 9.0x30mm L6IVL090030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
4 00195451000386 8.0x30mm L6IVL080030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
5 00195451000348 4.0x40mm S4IVLK4040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
6 00195451000331 3.5x40mm S4IVLK3540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
7 00195451000324 3.0x40mm S4IVLK3040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
8 00195451000317 2.5x40mm S4IVLK2540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
9 00195451000287 8.0x60mm M5PIVL8060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
10 00195451000270 7.0x60mm M5PIVL7060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
11 00195451000263 6.5x60mm M5PIVL6560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
12 00195451000256 6.0x60mm M5PIVL6060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
13 00195451000249 5.5x60mm M5PIVL5560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
14 00195451000232 5.0x60mm M5PIVL5060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
15 00195451000225 4.5x60mm M5PIVL4560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
16 00195451000218 4.0x60mm M5PIVL4060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
17 00195451000201 3.5x60mm M5PIVL3560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
18 00195377108135 5050196 PULSE Array, Cios Left PULSE NUVASIVE, INC.
19 00195377108128 5050195 PULSE Array, Cios Right PULSE NUVASIVE, INC.
20 00195377081681 LNPULSENAVINS Pulse Loaner Nav Instrument Set PULSE NUVASIVE, INC.
21 00195377081674 LNPULSELRTABLET Pulse Loaner LessRay Tablet Set PULSE NUVASIVE, INC.
22 00195377081667 LNPULSELRGE9 Pulse Loaner LessRay GE 9in Set PULSE NUVASIVE, INC.
23 00195377081636 LNPULSELRBED Pulse Loaner LessRay Bed Array Set PULSE NUVASIVE, INC.
24 00195377081629 LNPULSEIOM Pulse Loaner IOM Set PULSE NUVASIVE, INC.
25 00195377081605 LNPULSEDRILLGUIDE Pulse Loaner Drill Guide PULSE NUVASIVE, INC.
26 00195377081490 LNPULSECAMCART Pulse Loaner Camera Cart Set PULSE NUVASIVE, INC.
27 00195377081483 LNPULSECAM Pulse Loaner Camera Set PULSE NUVASIVE, INC.
28 00195377065544 1802497 PULSE Software, v4.0.0-bln.eu PULSE NUVASIVE, INC.
29 00195377065537 1802495 PULSE Software, v4.0.0-bln.us PULSE NUVASIVE, INC.
30 00195377065520 1802493 PULSE Software, v4.0.0-bl.eu PULSE NUVASIVE, INC.
31 00195377065513 1802491 PULSE Software, v4.0.0-bl.us PULSE NUVASIVE, INC.
32 00195377065506 1802489 PULSE Software, Base Image PULSE NUVASIVE, INC.
33 00195377062406 PULSELRTABLET Pulse LessRay Tablet Set PULSE NUVASIVE, INC.
34 00195377062239 PULSEIOM Pulse IOM Set PULSE NUVASIVE, INC.
35 00195377062222 BETPULSEIOM Pulse IOM Set - BETA PULSE NUVASIVE, INC.
36 00195377061379 5000504 PULSE Camera PULSE NUVASIVE, INC.
37 00195377061331 1833072 PULSE Cart Power and Data Cable, Kit PULSE NUVASIVE, INC.
38 00195377061188 BETPULSELRTABLET Pulse LessRay Tablet Set - BETA PULSE NUVASIVE, INC.
39 00195377060723 PULSELRGE9 Pulse LessRay GE 9in Set PULSE NUVASIVE, INC.
40 00195377060716 PULSELRGE12 Pulse LessRay GE 12in Set PULSE NUVASIVE, INC.
41 00195377060709 PULSELRCIOS Pulse LR Cios Set PULSE NUVASIVE, INC.
42 00195377060693 PULSEDRLLGUIDEM Pulse Drill Guide Mesh Set PULSE NUVASIVE, INC.
43 00195377060686 PULSEDRILLGUIDE Pulse Drill Guide PULSE NUVASIVE, INC.
44 00195377060679 BETPULSENAVINSM2 Pulse Nav Instrument Mesh Set 2 - BETA PULSE NUVASIVE, INC.
45 00195377060662 BETPULSENAVINSM1 Pulse Nav Instrument Mesh Set 1 - BETA PULSE NUVASIVE, INC.
46 00195377060655 BETPULSELRGE9 Pulse LessRay GE 9in Set - BETA PULSE NUVASIVE, INC.
47 00195377060648 BETPULSELRGE12 Pulse LessRay GE 12in Set - BETA PULSE NUVASIVE, INC.
48 00195377060631 BETPULSELRCIOS Pulse LR Cios Set - BETA PULSE NUVASIVE, INC.
49 00195377060624 BETPULSEDRLLGUIDEM Pulse Drill Guide Mesh Set - BETA PULSE NUVASIVE, INC.
50 00195377060617 BETPULSEDRILLGUIDE Pulse Drill Guide - BETA PULSE NUVASIVE, INC.