Other products from "SKELETAL DYNAMICS L.L.C."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00841507516201 K-Wire, Diamond Tip, 1.6mm x 127mm KWIR-SD-16127 HRS Plate, fixation, bone 2 Ulna Shortening Plating System
2 00841507516195 Drill, 3.5mm x 40mm DRLL-SSC-35040 HRS Plate, fixation, bone 2 Ulna Shortening Plating System
3 00841507416181 Cutting Blade, Proximal USP-CBP HRS Plate, fixation, bone 2 Ulna Shortening Plating System
4 00841507316177 Cutting Blade, Distal USP-CBD HRS Plate, fixation, bone 2 Ulna Shortening Plating System
5 00841507216163 Cottle Osteotome, 2.0mm C-OST-20 HRS Plate, fixation, bone 2 Ulna Shortening Plating System
6 00841506916132 Ulnar Shortening, Cutting Guide, Distal, Left CUTG-DIST-L HRS Plate, fixation, bone 2 Ulna Shortening Plating System
7 00841506516097 Ulnar Shortening, Cutting Guide, Proximal, Left CUTG-PRX-L HRS Plate, fixation, bone 2 Ulna Shortening Plating System
8 00841506416083 Ulnar Shortening, Cutting Guide, Proximal, Right CUTG-PRX-R HRS Plate, fixation, bone 2 Ulna Shortening Plating System
9 00841506316666 Ulnar Shortening Plating System Sterilization Tray USP-TRAY HRS Plate, fixation, bone 2 Ulna Shortening Plating System
10 00841506316079 Ulnar Shortening Plate, Distal, Short, Left USP-DLS HRS Plate, fixation, bone 2 Ulna Shortening Plating System
11 00841506216065 Ulnar Shortening Plate, Distal, Short, Right USP-DRS HRS Plate, fixation, bone 2 Ulna Shortening Plating System
12 00841506116303 Humeral Plating Set Tray A HPS-TRAY-A HRS Plate, fixation, bone 2 Humeral Plating System
13 00841506116051 Forceps, Bone Holding Medium, Compression FRCP-BHM-COM HRS Plate, fixation, bone 2 Ulna Shortening Plating System
14 00841506116037 Oblique Compression Hole Guide TPDG-CHG HRS Plate, fixation, bone 2 Ulna Shortening Plating System
15 00841506115894 Depth Gauge, MT, 80mm DPGA-MT-080 HWC Screw, fixation, bone 2 Humeral Plating System
16 00841506115887 FreeFix Depth Gage DPGA-FF-050 HRS Plate, fixation, bone 2 Forearm Plating System
17 00841506115818 Countersink, 6.5mm DRLL-CSK-65 HRS,HWC Plate, fixation, bone,Screw, fixation, bone 2 Humeral Plating System
18 00841506115801 Drill, 3.2mm / 4.5mm DRLL-STP-3245 HRS,HWC Plate, fixation, bone,Screw, fixation, bone 2 Humeral Plating System
19 00841506115764 Thread-In Drill Guide, FreeFix, 4.5mm TPDG-FF-45 HRS Plate, fixation, bone 2 Humeral Plating System
20 00841506115757 Thread-In Drill Guide, FreeFix, 3.5mm TPDG-FF-35 HRS Plate, fixation, bone 2 Ulna Shortening Plating System
21 00841506115740 FreeFix Midshaft Radius Plate, 188mm MRP-188 HRS Plate, fixation, bone 2 Forearm Plating System
22 00841506115696 Distal Trochlea Compression Screw, 3.5mm x 80mm, Ti DTCS-35080 HRS Plate, fixation, bone 2 Humeral Plating System
23 00841506115689 Distal Trochlea Compression Screw, 3.5mm x 75mm, Ti DTCS-35075 HRS Plate, fixation, bone 2 Humeral Plating System
24 00841506115672 Distal Trochlea Compression Screw, 3.5mm x 70mm, Ti DTCS-35070 HRS Plate, fixation, bone 2 Humeral Plating System
25 00841506115665 Distal Trochlea Compression Screw, 3.5mm x 65mm, Ti DTCS-35065 HRS Plate, fixation, bone 2 Humeral Plating System
26 00841506115641 Distal Trochlea Compression Screw, 3.5mm x 55mm, Ti DTCS-35055 HRS Plate, fixation, bone 2 Humeral Plating System
27 00841506115634 Distal Trochlea Compression Screw, 3.5mm x 50mm, Ti DTCS-35050 HRS Plate, fixation, bone 2 Humeral Plating System
28 00841506115610 Distal Trochlea Compression Screw, 3.5mm x 40mm, Ti DTCS-35040 HRS Plate, fixation, bone 2 Humeral Plating System
29 00841506115399 FreeFix Midshaft Ulna Plate, 157mm MUP-157 HRS Plate, fixation, bone 2 Forearm Plating System
30 00841506115382 FreeFix Midshaft Ulna Plate, 127mm MUP-127 HRS Plate, fixation, bone 2 Forearm Plating System
31 00841506115375 FreeFix Midshaft Ulna Plate, 112mm MUP-112 HRS Plate, fixation, bone 2 Forearm Plating System
32 00841506114989 Drill, 2.0mm x 80mm DRLL-SSC-20080 HRS Plate, fixation, bone 2 Humeral Plating System
33 00841506114842 Hohmann Retractor, Large INST-HR-LRG HRS Plate, fixation, bone 2 Humeral Plating System
34 00841506114811 Bending Rod, DHP BND-ROD-DHP HRS Plate, fixation, bone 2 Humeral Plating System
35 00841506114729 K-Wire, Single Trocar, 1.5 mm x 229 mm KWIR-ST-15229 HRS Plate, fixation, bone 2 Humeral Plating System
36 00841506114699 Universal Bending Irons, 4.5mm UNV-BND-45 HRS Plate, fixation, bone 2 Humeral Plating System
37 00841506114590 FreeFix Midshaft Radius Plate, 142mm MRP-142 HRS Plate, fixation, bone 2 Forearm Plating System
38 00841506114583 FreeFix Midshaft Radius Plate, 112mm MRP-112 HRS Plate, fixation, bone 2 Forearm Plating System
39 00841506114576 FreeFix Midshaft Radius Plate, 81mm MRP-081 HRS Plate, fixation, bone 2 Forearm Plating System
40 00841506113012 FreeFix Midshaft Radius Plate, 157mm MRP-157 HRS Plate, fixation, bone 2 Forearm Plating System
41 00841506112992 FreeFix Midshaft Radius Plate, 97mm MRP-097 HRS Plate, fixation, bone 2 Forearm Plating System
42 00841506112732 Drill Guide, FreeFix™, 2.7mm TPDG-FF-27ML HRS Plate, fixation, bone 2 Forearm Plating System
43 00841506112527 Distal Humerus Plate, Lateral Direct, 175mm, Left DHP-LDL-9HL HRS Plate, fixation, bone 2 Humeral Plating System
44 00841506112510 Distal Humerus Plate, Lateral Direct, 175mm, Right DHP-LDR-9HL HRS Plate, fixation, bone 2 Humeral Plating System
45 00841506112503 Distal Humerus Plate, Lateral Direct, 145mm, Left DHP-LDL-7HL HRS Plate, fixation, bone 2 Humeral Plating System
46 00841506112480 Distal Humerus Plate, Lateral Direct, 115mm, Left DHP-LDL-5HL HRS Plate, fixation, bone 2 Humeral Plating System
47 00841506112435 Drill, Cannulated, 3.7mm x 80mm DRLL-CDC-37080 HRS Plate, fixation, bone 2 Humeral Plating System
48 00841506111544 Midshaft Humerus Plate, Narrow 244mm MHN-244 HRS Plate, fixation, bone 2 Humeral Plating System
49 00841506111537 Midshaft Humerus Plate, Narrow 208mm MHN-208 HRS Plate, fixation, bone 2 Humeral Plating System
50 00841506111520 Midshaft Humerus Plate, Narrow 172mm MHN-172 HRS Plate, fixation, bone 2 Humeral Plating System
Other products with the same Product Code "HWC"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10381780441380 MBAIMP MBAIMP MBA Implant Set MBA™ Titanium Subtalar Implant System ASCENSION ORTHOPEDICS, INC.
2 10381780257288 MBASET MBA™ Instrument Set (05-5000) MBA™ ASCENSION ORTHOPEDICS, INC.
3 10381780257271 KOMPSET Kompressor™ Instrument Set (21-5000) Kompressor™ ASCENSION ORTHOPEDICS, INC.
4 10381780237686 TRL-1006-C06 The Integra Titanium Bone Wedges are a series of wedge-shaped devices intended t The Integra Titanium Bone Wedges are a series of wedge-shaped devices intended to be used for angular correction of small bones in the ankle and foot. The Integra Titanium Bone Wedges are constructed from commercially pure titanium formed into a cancellous-like structure. Trial Cotton 20 X 6.5 TiWedge™ ASCENSION ORTHOPEDICS, INC.
5 10381780237679 TRL-1006-C05 The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is co The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
6 10381780237662 TRL-1006-C04 The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is co The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
7 10381780237655 TRL-1006-C03 The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is co The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
8 10381780237648 TRL-1006-C02 The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is co The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
9 10381780237631 TRL-1006-C01 The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is co The Integra® Titanium Cotton Wedge Trials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
10 10381780237624 TRL-1006-L09 The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congr The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
11 10381780237617 TRL-1006-L08 The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congr The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
12 10381780237600 TRL-1006-L07 The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congr The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
13 10381780237594 TRL-1006-L06 The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congr The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
14 10381780237587 TRL-1006-L05 The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congr The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
15 10381780237570 TRL-1006-L04 The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congr The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
16 10381780237563 TRL-1006-L03 The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congr The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
17 10381780237556 TRL-1006-L02 The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congr The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
18 10381780237549 TRL-1006-L01 The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congr The Integra® Titanium Bone WedgeTrials are inserted until the footprint is congruent to the dimensions of the osteotomy surface, and the desired amount of correction is achieved. The trial is to confirm that the implanted wedge will be congruent with the osteotomy surface to provide the most optimal site for ingrowth of bone into the wedge. TiWedge™ ASCENSION ORTHOPEDICS, INC.
19 10381780237471 TIWEDGEINSTP The Integra Titanium Bone Wedge is intended to be used for internal bone fixatio The Integra Titanium Bone Wedge is intended to be used for internal bone fixation for bone fractures or osteotomies in the ankle and foot. This set includes LCL trials and cotton trials to evaluate proper size and fit of the implants. A wedge inserter and tamp are also included for assistance. TiWedgeTM ASCENSION ORTHOPEDICS, INC.
20 10381780124948 TBW-1006-2065 TBW-1006-2065 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
21 10381780124931 TBW-1006-2055 TBW-1006-2055 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
22 10381780124924 TBW-1006-2045 TBW-1006-2045 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
23 10381780124917 TBW-1006-1665 TBW-1006-1665 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
24 10381780124900 TBW-1006-1655 TBW-1006-1655 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
25 10381780124894 TBW-1006-1645 TBW-1006-1645 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
26 10381780124887 TBW-1006-LG12 TBW-1006-LG12 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
27 10381780124870 TBW-1006-LG10 TBW-1006-LG10 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
28 10381780124863 TBW-1006-LG8 TBW-1006-LG8 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
29 10381780124856 TBW-1006-MD12 TBW-1006-MD12 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
30 10381780124849 TBW-1006-MD10 TBW-1006-MD10 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
31 10381780124832 TBW-1006-MD8 TBW-1006-MD8 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
32 10381780124825 TBW-1006-SM12 TBW-1006-SM12 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
33 10381780124818 TBW-1006-SM10 TBW-1006-SM10 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
34 10381780124801 TBW-1006-SM8 TBW-1006-SM8 The Integra® Titanium Bone Wedges are intended to be used for internal bone fixa The Integra® Titanium Bone Wedges are intended to be used for internal bone fixation for bone fracturesor osteotomies in the ankle and foot Integra® Titanium Bone Wedge System ASCENSION ORTHOPEDICS, INC.
35 10381780123064 CSS500000670WT CSS500000670WT The washer is used in conjunction with the Capture High Torque Screw System. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
36 10381780123057 CSS500000650WT CSS500000650WT The washer is used in conjunction with the Capture High Torque Screw System. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
37 10381780123040 CSS500000640WT CSS500000640WT The washer is used in conjunction with the Capture High Torque Screw System. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
38 10381780123033 CSS500000630WT CSS500000630WT The washer is used in conjunction with the Capture High Torque Screw System. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
39 10381780123026 CSS500000625WT CSS500000625WT The washer is used in conjunction with the Capture High Torque Screw System. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
40 10381780123019 CSS50000052540T CSS50000052540T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
41 10381780123002 CSS50000052535T CSS50000052535T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
42 10381780122999 CSS50000052530T CSS50000052530T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
43 10381780122982 CSS50000052528T CSS50000052528T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
44 10381780122975 CSS50000052526T CSS50000052526T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
45 10381780122968 CSS50000052524T CSS50000052524T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
46 10381780122951 CSS50000052522T CSS50000052522T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
47 10381780122944 CSS50000052520T CSS50000052520T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
48 10381780122937 CSS50000052518T CSS50000052518T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
49 10381780122920 CSS50000052516T CSS50000052516T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.
50 10381780122913 CSS50000052514T CSS50000052514T Cannulated screw is a machined, metallic screw that is manufactured from stainle Cannulated screw is a machined, metallic screw that is manufactured from stainless steel and titanium with a cannulation that is self-drilling and self-tapping. The CAPTURE High-Torque Screw is intended for fixation of the pelvis and illiosacral join, as well as fixations of fractures and osteotomies in long and small bones, including those in the foot, patella, ankle, wrist, and elbow. Intended for use correction Arthrodesis of the foot, wrist and elbow. CAPTURE™ High Torque Screw System ASCENSION ORTHOPEDICS, INC.