Revogene - The system is a clinical multiplex instrument - MERIDIAN BIOSCIENCE, INC.

Duns Number:092815364

Device Description: The system is a clinical multiplex instrument intended to measure and sort multiple signal The system is a clinical multiplex instrument intended to measure and sort multiple signals generated my multiple probes, intercalating dyes, or other ligands in an assay from a clinical sample. Signals may be generated by fluorescence or other phenomena and may be measured using filters on a photodiode or other detector. It may integrate sample and/or reagent handling, amplification, dedicated instrument control, data acquisition software, raw data storage mechanisms and other essential hardware components along with the signal reader unit. The system is used with specific assays to comprise an assay test system. A real-time thermocycler is intended to identify and/or quantify the presence of specific sequences of double stranded DNA, amplified from a biological source and labeled with fluorescently labeled probes or through the use of intercalating dyes and detect using a high-power light-emitting diode (LED). Fluorescence emission is detected through the use of filters on a photodiode. The emission filters are optimized for use with specific fluorescent dyes.

Want to know more about this Product? Request more information now!


More Product Details

Catalog Number

610210

Brand Name

Revogene

Version/Model Number

610210

Device Commercial Distribution Status

In Commercial Distribution

Commercial Distribution End Date

-

Issuing Agency

In GS1

Product Characteristics

MRI safety Status

Labeling does not contain MRI Safety Information

Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)

-

Device labeled as "Not made with natural rubber latex"

-

For Single-Use

-

Prescription Use (Rx)

Yes

Over the Counter (OTC)

-

Kit

-

Combination Product

-

Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)

-

FDA Premarket Submission

K170558

Product Code Details

Product Code

OOI

Product Code Name

Real Time Nucleic Acid Amplification System

Device Record Status

Public Device Record Key

20c66b24-da19-4cab-928e-d01d111b52c9

Public Version Date

September 16, 2022

Public Version Number

2

DI Record Publish Date

July 15, 2020

Additional Identifiers

Package DI Number

None

Quantity per Package

-

Contains DI Package

-

Package Discontinue Date

-

Package Status

-

Package Type

-

"MERIDIAN BIOSCIENCE, INC." Characteristics
Device Class Device Class Description No of Devices
1 A medical device with low to moderate risk that requires general controls 149
2 A medical device with a moderate to high risk that requires special controls. 46
3 A medical device with high risk that requires premarket approval 1