Duns Number:092815364
Device Description: The system is a clinical multiplex instrument intended to measure and sort multiple signal The system is a clinical multiplex instrument intended to measure and sort multiple signals generated my multiple probes, intercalating dyes, or other ligands in an assay from a clinical sample. Signals may be generated by fluorescence or other phenomena and may be measured using filters on a photodiode or other detector. It may integrate sample and/or reagent handling, amplification, dedicated instrument control, data acquisition software, raw data storage mechanisms and other essential hardware components along with the signal reader unit. The system is used with specific assays to comprise an assay test system. A real-time thermocycler is intended to identify and/or quantify the presence of specific sequences of double stranded DNA, amplified from a biological source and labeled with fluorescently labeled probes or through the use of intercalating dyes and detect using a high-power light-emitting diode (LED). Fluorescence emission is detected through the use of filters on a photodiode. The emission filters are optimized for use with specific fluorescent dyes.
Catalog Number
610210
Brand Name
Revogene
Version/Model Number
610210
Device Commercial Distribution Status
In Commercial Distribution
Commercial Distribution End Date
-
Issuing Agency
In GS1
MRI safety Status
Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)
-
Device labeled as "Not made with natural rubber latex"
-
For Single-Use
-
Prescription Use (Rx)
Yes
Over the Counter (OTC)
-
Kit
-
Combination Product
-
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)
-
FDA Premarket Submission
K170558
Product Code
OOI
Product Code Name
Real Time Nucleic Acid Amplification System
Public Device Record Key
20c66b24-da19-4cab-928e-d01d111b52c9
Public Version Date
September 16, 2022
Public Version Number
2
DI Record Publish Date
July 15, 2020
Package DI Number
None
Quantity per Package
-
Contains DI Package
-
Package Discontinue Date
-
Package Status
-
Package Type
-
Device Class | Device Class Description | No of Devices |
---|---|---|
1 | A medical device with low to moderate risk that requires general controls | 149 |
2 | A medical device with a moderate to high risk that requires special controls. | 46 |
3 | A medical device with high risk that requires premarket approval | 1 |