Other products from "GE MEDICAL SYSTEMS"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00840682142052 EKB2 MUE Full field digital, system, x-ray, mammographic 2 Senographe Pristina
2 00840682118460 EKB1 MUE,IWX,ITY,FMQ,IZO,IXJ,IZW Full field digital,system,x-ray,mammographic,Barrier, control panel, x-ray, mova Full field digital,system,x-ray,mammographic,Barrier, control panel, x-ray, movable,Assembly, tube housing, x-ray, diagnostic,Restraint, protective,Generator, high-voltage, x-ray, diagnostic,Grid, radiographic,Collimator, automatic, radiographic 1 Senographe Pristina
3 00840682145879 EKB3 MUE Full field digital, system, x-ray, mammographic 2 Senographe Pristina
4 00840682141307 IGS WF SP OWB,OXO,IZI,JAA Interventional fluoroscopic x-ray system,Image-intensified fluoroscopic x-ray sy Interventional fluoroscopic x-ray system,Image-intensified fluoroscopic x-ray system, mobile,System, x-ray, angiographic,System, x-ray, fluoroscopic, image-intensified 2 NA
5 00840682117852 Accelera V5 MUE Full field digital,system,x-ray,mammographic 2 NA
6 00840682102278 4.7 LLZ System, image processing, radiological 2 AW
7 00195278276971 EKB6 Senographe Pristina Core System MUE Full field digital, system, x-ray, mammographic 2 Senographe Pristina
8 00195278223937 EKB5 Senographe Pristina Core System MUE Full field digital, system, x-ray, mammographic 2 Senographe Pristina
9 00195278022745 EKB4 Senographe Pristina Core System MUE Full field digital, system, x-ray, mammographic 2 Senographe Pristina
10 00840682142038 M3-2 SP1 STD+ OTE Digital breast tomosynthesis 3 not applicable
11 00840682146845 PRISTINA 2.0 Software Pristina Infinity OTE,MUE Digital breast tomosynthesis,Full field digital, system, x-ray, mammographic 2 not applicable
12 00840682145862 PRISTINA 0.0A MUE Full field digital, system, x-ray, mammographic 2 not applicable
13 00840682143516 PRISTINA 0.0 MUE Full field digital, system, x-ray, mammographic 2 not applicable
14 00840682142373 PRISTINA 0.1 MUE Full field digital, system, x-ray, mammographic 2 not applicable
15 00840682141284 NA IZI,OWB,JAA,OXO System, x-ray, angiographic,Interventional fluoroscopic x-ray system,System, x-r System, x-ray, angiographic,Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-intensified,Image-intensified fluoroscopic x-ray system, mobile 2 IGS WF BP
16 00840682139229 KAS1 MUE Full field digital, system, x-ray, mammographic 2 Pristina Serena
17 00840682125802 M3-2 MUE Full field digital,system,x-ray,mammographic 2 not applicable
18 00840682122603 5727669 IZO,FMQ,IWX,IXJ,ITY,MUE,IZW Generator, high-voltage, x-ray, diagnostic,Restraint, protective,Barrier, contro Generator, high-voltage, x-ray, diagnostic,Restraint, protective,Barrier, control panel, x-ray, movable,Grid, radiographic,Assembly, tube housing, x-ray, diagnostic,Full field digital,system,x-ray,mammographic,Collimator, automatic, radiographic 1 not applicable
19 00195278347596 KAS2 Biopsy Option MUE Full field digital, system, x-ray, mammographic 2 Pristina Serena
20 00195278009289 PRISTINA 0.0B OTE,MUE Digital breast tomosynthesis,Full field digital, system, x-ray, mammographic 2 not applicable
21 00840682124638 IGS 7 001 OXO,OWB,JAA,IZI Image-Intensified Fluoroscopic X-Ray System, Mobile,Interventional Fluoroscopic Image-Intensified Fluoroscopic X-Ray System, Mobile,Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified,System, X-Ray, Angiographic 2 DISCOVERY
22 00840682120142 ATA1 OTE Digital breast tomosynthesis 3 Senographe Pristina 3D
23 00840682110693 IGS 740 002 DISCOVERY IGS 740 002 JAA,OWB,OXO System, x-ray, fluoroscopic, image-intensified,Interventional fluoroscopic x-ray System, x-ray, fluoroscopic, image-intensified,Interventional fluoroscopic x-ray system,Image-intensified fluoroscopic x-ray system, mobile 2 DISCOVERY
24 00840682110648 IGS 730 002 DISCOVERY IGS 730 002 OWB,JAA,IZI Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-inte Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-intensified,System, x-ray, angiographic 2 DISCOVERY
25 00840682104739 IGS 730 001 OWB,JAA,IZI Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-inte Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-intensified,System, x-ray, angiographic 2 DISCOVERY
26 00195278194039 ATA2 Kit upgrade HW Single PC Infinity OTE Digital breast tomosynthesis 3 Senographe Pristina 3D
27 00840682143424 BSP1 MUE Full field digital, system, x-ray, mammographic 2 Breast Spacer
28 00840682139397 JMM1 MUE Full field digital, system, x-ray, mammographic 2 Horizontal
29 00840682121064 GPE1 MUE Full field digital,system,x-ray,mammographic 2 SenoBright
30 00195278485168 IGS 3 5874604 Allia IGS3 UDI JAA,OWB,IZI System, x-ray, fluoroscopic, image-intensified,Interventional fluoroscopic x-ray System, x-ray, fluoroscopic, image-intensified,Interventional fluoroscopic x-ray system,System, x-ray, angiographic 2 Allia
31 00195278485144 IGS 5 5872892 Allia IGS5 UDI OWB,JAA,IZI Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-inte Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-intensified,System, x-ray, angiographic 2 Allia
32 00195278215550 IGS 7 OR 001 5855630 Allia IGS 7 OR UDI OWB,JAA,IZI,OXO Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-inte Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-intensified,System, x-ray, angiographic,Image-intensified fluoroscopic x-ray system, mobile 2 Allia
33 00195278215543 IGS 7 001 5855628 Allia IGS 7 UDI JAA,IZI,OXO,OWB System, x-ray, fluoroscopic, image-intensified,System, x-ray, angiographic,Image System, x-ray, fluoroscopic, image-intensified,System, x-ray, angiographic,Image-intensified fluoroscopic x-ray system, mobile,Interventional fluoroscopic x-ray system 2 Allia
34 00840682138826 MAG5 FMQ Restraint, protective 1 MagStand 1.5
35 00840682125888 IGS 7 OR 001 OXO,OWB,JAA,IZI Image-Intensified Fluoroscopic X-Ray System, Mobile,Interventional Fluoroscopic Image-Intensified Fluoroscopic X-Ray System, Mobile,Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified,System, X-Ray, Angiographic 2 Discovery
36 00840682123297 EST6 IZH System, x-ray, mammographic 2 Senographe Essential Stereotaxy
37 00840682147767 1 LLZ System, image processing, radiological 2 SenoIris
38 00840682143486 SIM1 MUE Full field digital, system, x-ray, mammographic 2 Sample Imaging
39 00840682102384 3.2 LLZ System, image processing, radiological 2 AW Server
40 00840682100076 LLH2 5434135-5 Digital Breast Tomosynthesis option for Senographe Essential OTE Digital Breast Tomosynthesis 3 SenoClaire
41 00840682100045 LLH1 5434135-4 Digital Breast Tomosynthesis option for Senographe Essential OTE Digital Breast Tomosynthesis 3 SenoClaire
42 00840682147378 IGS 3 001 OWB,JAA,IZI Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-inte Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-intensified,System, x-ray, angiographic 2 INNOVA
43 00840682141581 RT 001 JAK,JAA System, x-ray, tomography, computed,System, x-ray, fluoroscopic, image-intensified 2 INTERACT Discovery
44 00840682138802 MAG8 FMQ Restraint, protective 1 MagStand 1.8
45 00840682124621 IGS 5 001 Innova IGS 5 UDI JAA,OWB,IZI System, x-ray, fluoroscopic, image-intensified,Interventional fluoroscopic x-ray System, x-ray, fluoroscopic, image-intensified,Interventional fluoroscopic x-ray system,System, x-ray, angiographic 2 INNOVA
46 00840682124614 IGS 6 001 OWB,JAA,IZI Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Inte Interventional Fluoroscopic X-Ray System,System, X-Ray, Fluoroscopic, Image-Intensified,System, X-Ray, Angiographic 2 INNOVA
47 00840682123242 ES14 MUE Full field digital,system,x-ray,mammographic 2 Senographe Essential
48 00840682121637 UPG X100 001 IZI,OWB,JAA System, x-ray, angiographic,Interventional fluoroscopic x-ray system,System, x-r System, x-ray, angiographic,Interventional fluoroscopic x-ray system,System, x-ray, fluoroscopic, image-intensified 2 INNOVA
49 00840682110709 IGS 540 002 INNOVA IGS 540 002 OWB,IZI,JAA Interventional fluoroscopic x-ray system,System, x-ray, angiographic,System, x-r Interventional fluoroscopic x-ray system,System, x-ray, angiographic,System, x-ray, fluoroscopic, image-intensified 2 INNOVA
50 00840682110129 IGS 520 002 INNOVA IGS 520 002 OWB,IZI,JAA Interventional fluoroscopic x-ray system,System, x-ray, angiographic,System, x-r Interventional fluoroscopic x-ray system,System, x-ray, angiographic,System, x-ray, fluoroscopic, image-intensified 2 INNOVA
Other products with the same Product Codes "JAA, IZI, OWB"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00613994416209 BI40000015 SPACER BI40000015 O-ARM PATIENT SPACER O-ARM® MEDTRONIC NAVIGATION, INC.
2 00195451000416 12.0x30mm L6IVL120030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
3 00195451000409 10.0x30mm L6IVL100030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
4 00195451000393 9.0x30mm L6IVL090030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
5 00195451000386 8.0x30mm L6IVL080030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
6 00195451000348 4.0x40mm S4IVLK4040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
7 00195451000331 3.5x40mm S4IVLK3540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
8 00195451000324 3.0x40mm S4IVLK3040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
9 00195451000317 2.5x40mm S4IVLK2540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
10 00195451000287 8.0x60mm M5PIVL8060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
11 00195451000270 7.0x60mm M5PIVL7060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
12 00195451000263 6.5x60mm M5PIVL6560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
13 00195451000256 6.0x60mm M5PIVL6060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
14 00195451000249 5.5x60mm M5PIVL5560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
15 00195451000232 5.0x60mm M5PIVL5060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
16 00195451000225 4.5x60mm M5PIVL4560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
17 00195451000218 4.0x60mm M5PIVL4060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
18 00195451000201 3.5x60mm M5PIVL3560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
19 00195377108135 5050196 PULSE Array, Cios Left PULSE NUVASIVE, INC.
20 00195377108135 5050196 PULSE Array, Cios Left PULSE NUVASIVE, INC.
21 00195377108128 5050195 PULSE Array, Cios Right PULSE NUVASIVE, INC.
22 00195377108128 5050195 PULSE Array, Cios Right PULSE NUVASIVE, INC.
23 00195377081681 LNPULSENAVINS Pulse Loaner Nav Instrument Set PULSE NUVASIVE, INC.
24 00195377081681 LNPULSENAVINS Pulse Loaner Nav Instrument Set PULSE NUVASIVE, INC.
25 00195377081674 LNPULSELRTABLET Pulse Loaner LessRay Tablet Set PULSE NUVASIVE, INC.
26 00195377081674 LNPULSELRTABLET Pulse Loaner LessRay Tablet Set PULSE NUVASIVE, INC.
27 00195377081667 LNPULSELRGE9 Pulse Loaner LessRay GE 9in Set PULSE NUVASIVE, INC.
28 00195377081667 LNPULSELRGE9 Pulse Loaner LessRay GE 9in Set PULSE NUVASIVE, INC.
29 00195377081636 LNPULSELRBED Pulse Loaner LessRay Bed Array Set PULSE NUVASIVE, INC.
30 00195377081636 LNPULSELRBED Pulse Loaner LessRay Bed Array Set PULSE NUVASIVE, INC.
31 00195377081629 LNPULSEIOM Pulse Loaner IOM Set PULSE NUVASIVE, INC.
32 00195377081629 LNPULSEIOM Pulse Loaner IOM Set PULSE NUVASIVE, INC.
33 00195377081605 LNPULSEDRILLGUIDE Pulse Loaner Drill Guide PULSE NUVASIVE, INC.
34 00195377081605 LNPULSEDRILLGUIDE Pulse Loaner Drill Guide PULSE NUVASIVE, INC.
35 00195377081490 LNPULSECAMCART Pulse Loaner Camera Cart Set PULSE NUVASIVE, INC.
36 00195377081490 LNPULSECAMCART Pulse Loaner Camera Cart Set PULSE NUVASIVE, INC.
37 00195377081483 LNPULSECAM Pulse Loaner Camera Set PULSE NUVASIVE, INC.
38 00195377081483 LNPULSECAM Pulse Loaner Camera Set PULSE NUVASIVE, INC.
39 00195377065544 1802497 PULSE Software, v4.0.0-bln.eu PULSE NUVASIVE, INC.
40 00195377065544 1802497 PULSE Software, v4.0.0-bln.eu PULSE NUVASIVE, INC.
41 00195377065537 1802495 PULSE Software, v4.0.0-bln.us PULSE NUVASIVE, INC.
42 00195377065537 1802495 PULSE Software, v4.0.0-bln.us PULSE NUVASIVE, INC.
43 00195377065520 1802493 PULSE Software, v4.0.0-bl.eu PULSE NUVASIVE, INC.
44 00195377065520 1802493 PULSE Software, v4.0.0-bl.eu PULSE NUVASIVE, INC.
45 00195377065513 1802491 PULSE Software, v4.0.0-bl.us PULSE NUVASIVE, INC.
46 00195377065513 1802491 PULSE Software, v4.0.0-bl.us PULSE NUVASIVE, INC.
47 00195377065506 1802489 PULSE Software, Base Image PULSE NUVASIVE, INC.
48 00195377065506 1802489 PULSE Software, Base Image PULSE NUVASIVE, INC.
49 00195377062406 PULSELRTABLET Pulse LessRay Tablet Set PULSE NUVASIVE, INC.
50 00195377062406 PULSELRTABLET Pulse LessRay Tablet Set PULSE NUVASIVE, INC.