Other products from "LUMINEX CORPORATION"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00840487101803 40-50035 Sheath Fluid PLUS is the delivery medium of the sample to the optics component. NSU Instrumentation for clinical multiplex test systems 2 xMAP® Sheath Fluid PLUS
2 00840487101797 40-50020 The MAGPIX Drive Fluid PLUS serves as the delivery medium that carries the sampl The MAGPIX Drive Fluid PLUS serves as the delivery medium that carries the sample to the optics component of the MAGPIX instrument. NSU Instrumentation for clinical multiplex test systems 2 MAGPIX® Drive Fluid PLUS (4PK)
3 00840487101315 3909 3909 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® EBV Primers
4 00840487101742 3928 3928 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 Multicode® Mycoplasma genitalium Primers
5 00840487101612 20-006-024 20-006-024 The Verigene® Respiratory Pathogens Flex Nucleic Acid Test (RP Flex) is a multip The Verigene® Respiratory Pathogens Flex Nucleic Acid Test (RP Flex) is a multiplexed qualitative test intended for the simultaneous detection and identification of multiple viral and bacterial nucleic acids in nasopharyngeal swabs (NPS) obtained from individuals suspected of respiratory tract infection. OCC,OZE,OZZ,OEM,OOU,OEP Respiratory virus panel nucleic acid assay system,Influenza A and influenza B mu Respiratory virus panel nucleic acid assay system,Influenza A and influenza B multiplex nucleic acid assay,Bordetella pertussis dna assay system,Human metapneumovirus (hmpv) rna assay system,Parainfluenza multiplex nucleic acid assay,Influenza a virus subtype differentiation nucleic acid assay 2 Respiratory Pathogens Flex (RP Flex) Nucleic Acid Test Cartridge
6 00840487101544 20-011-023 20-011-023 The Verigene® Enteric Pathogens Nucleic Acid Test (EP) is a multiplexed, qualita The Verigene® Enteric Pathogens Nucleic Acid Test (EP) is a multiplexed, qualitative test for simultaneous detection and identification of common pathogenic enteric bacteria, viruses, and genetic virulence markers from liquid or soft stool preserved in Cary-Blair medium, collected from individuals with signs and symptoms of gastrointestinal infection. PCH,PCI Gastrointestinal pathogen panel multiplex nucleic acid-based assay system,Gastro Gastrointestinal pathogen panel multiplex nucleic acid-based assay system,Gastrointestinal bacterial panel multiplex nucleic acid-based assay system 2 Enteric Pathogens (EP) Amplification Tray
7 00840487101506 10-0000-04 10-0000-04 The Verigene® Processor is an instrument which internalizes all of the functions The Verigene® Processor is an instrument which internalizes all of the functions required to process a Test Cartridge as part of the Verigene® System, a benchtop molecular diagnostics workstation that utilizes patented gold nanoparticle technology to detect nucleic acid targets of interest for a variety of applications. NSU Instrumentation for clinical multiplex test systems 2 Verigene® Processor
8 00840487101490 10-0000-07R 10-0000-07R The Verigene® Processor SP is an instrument which integrates sample preparation, The Verigene® Processor SP is an instrument which integrates sample preparation, target amplification, and target hybridization within a single device as part of the Verigene® System, a benchtop molecular diagnostics workstation that utilizes patented gold nanoparticle technology to detect nucleic acid targets of interest for a variety of applications. (Refurbished) NSU,OOI Instrumentation for clinical multiplex test systems,real time Nucleic acid ampli Instrumentation for clinical multiplex test systems,real time Nucleic acid amplification system 2 Verigene® Processor SP (Refurbished)
9 00840487101322 3909-21 3909-21 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® EBV Primers
10 00840487101216 3804-22 3804-22 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV Control Primers 3
11 00840487101209 3804-21 3804-21 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV Control Primers 3
12 00840487101193 3804 3804 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV Control Primers 3
13 00840487101186 3803-21 3803-21 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV Control Primers 2
14 00840487101179 3803 3803 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV Control Primers 2
15 00840487100332 LX200-CON-K25 xMAP Control Microspheres, Classification (CON1) and Reporter (CON2), are polyst xMAP Control Microspheres, Classification (CON1) and Reporter (CON2), are polystyrene microspheres that are internally labeled with fluorescent dyes. The control microspheres are intended to verify the calibration and optical integrity for the Luminex 100/200 System. Classification Control Microspheres verify both classification channels and the doublet discriminator channel (DD). Reporter Control Microspheres verify the reporter channel. NSU Instrumentation for clinical multiplex test systems 2 Luminex® 100/200™ Performance Verification Kit
16 00840487100288 MPXIVD-PVER-K25 The Luminex MAGPIX Performance Verification Kit is intended to verify the optica The Luminex MAGPIX Performance Verification Kit is intended to verify the optical calibration of the MAGPIX instrument. NSU Instrumentation for clinical multiplex test systems 2 MAGPIX® Performance Verification Kit
17 00840487100271 MPXIVD-CAL-K25 The Luminex MAGPIX Calibration Kit is intended to calibrate the optics of the MA The Luminex MAGPIX Calibration Kit is intended to calibrate the optics of the MAGPIX instrument. During calibration, the system adjusts LED current and calibration factors for CL1, CL2, and RP1 until those values match the imported target values, thus calibrating the classification map. NSU Instrumentation for clinical multiplex test systems 2 MAGPIX® Calibration Kit
18 00840487100158 50-10020 The ARIES® Flu A/B & RSV Assay is a polymerase chain reaction (PCR) based qualit The ARIES® Flu A/B & RSV Assay is a polymerase chain reaction (PCR) based qualitative in vitro diagnostic test for the direct detection and differentiation of influenza A virus, influenza B virus, and respiratory syncytial virus (RSV) nucleic acid in nasopharyngeal swabs (NPS) specimens from patients with signs and symptoms of respiratory tract infection in conjunction with clinical and laboratory findings. OZE,OCC Influenza A and influenza B multiplex nucleic acid assay,Respiratory virus panel Influenza A and influenza B multiplex nucleic acid assay,Respiratory virus panel nucleic acid assay system 2 ARIES® Flu A/B & RSV Assay
19 00840487100080 ARIES M6V1 The ARIES® M1 System is a clinical multiplex test system that automates and inte The ARIES® M1 System is a clinical multiplex test system that automates and integrates extraction of nucleic acid from a clinical sample, performs real -time PCR, and measuring and sorting multiple signals generated in an in vitro diagnostic assay. OOI real time Nucleic acid amplification system 2 ARIES® M1 System
20 00840487101766 VERIGENE-II-6M-IVD The VERIGENE® II System is an in vitro diagnostic (IVD) platform that performs n The VERIGENE® II System is an in vitro diagnostic (IVD) platform that performs nucleic acid based tests in clinical laboratories. The VERIGENE II System is capable of automated extraction and purification of nucleic acids from multiple sample types as well as automated amplification, array hybridization, and detection of target nucleic acid sequences. NSU Instrumentation for clinical multiplex test systems 2 VERIGENE® II System
21 00840487101711 20-011-024 20-011-024 The Verigene® Respiratory Pathogens Flex Nucleic Acid Test (RP Flex) is a multip The Verigene® Respiratory Pathogens Flex Nucleic Acid Test (RP Flex) is a multiplexed qualitative test intended for the simultaneous detection and identification of multiple viral and bacterial nucleic acids in nasopharyngeal swabs (NPS) obtained from individuals suspected of respiratory tract infection. OEP,OCC,OZZ,OZE,OEM,OOU Influenza a virus subtype differentiation nucleic acid assay,Respiratory virus p Influenza a virus subtype differentiation nucleic acid assay,Respiratory virus panel nucleic acid assay system,Bordetella pertussis dna assay system,Influenza A and influenza B multiplex nucleic acid assay,Human metapneumovirus (hmpv) rna assay system,Parainfluenza multiplex nucleic acid assay 2 Respiratory Pathogens Flex (RP Flex) Amplification Tray
22 00840487101377 3916 3916 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® VZV Primers
23 00840487101353 3914 3914 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® Adenovirus Primers
24 00840487101162 3802-21 3802-21 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV Control Primers 1
25 00840487101155 3802 3802 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV Control Primers 1
26 00840487101124 3694-22 3694-22 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV DNA Amplification Control
27 00840487101117 3694-21 3694-21 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV DNA Amplification Control
28 00840487101100 3694 3694 Internal control used in real-time polymerase chain reaction (pcr) assays to det Internal control used in real-time polymerase chain reaction (pcr) assays to detect systemic variation that may arise during the extraction and amplification process associated with real-time pcr assays. It is not intended to monitor other real-time pcr processes. OLD Internal polymerase chain reaction control, not assay specific 1 MHV DNA Amplification Control
29 00840487100257 3927 3927 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® Mycoplasma pneumoniae Primers
30 00840487100219 3923 3923 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® Group A Strep Primers
31 00840487100073 50-10026 The ARIES® Extraction Kit is intended to extract nucleic acid from human biologi The ARIES® Extraction Kit is intended to extract nucleic acid from human biological specimens and universal transport media (UTM). OOI real time Nucleic acid amplification system 2 ARIES® Extraction Kit
32 00840487101780 40-50036 A concentrated version of xMAP® Sheath Fluid PLUS, when diluted is is the delive A concentrated version of xMAP® Sheath Fluid PLUS, when diluted is is the delivery medium of the sample to the optics component. NSU Instrumentation for clinical multiplex test systems 2 xMAP® Sheath Concentrate PLUS
33 00840487101735 30-002-022 30-002-022 The Verigene® Clostridium difficile Nucleic Acid Test (CDF) is a qualitative mul The Verigene® Clostridium difficile Nucleic Acid Test (CDF) is a qualitative multiplexed in vitro diagnostic test for the rapid detection of toxin A (tcdA), toxin B (tcdB), and tcdC gene sequences of toxigenic Clostridium difficile and for presumptive identification of PCR ribotype 027 strains from unformed (liquid or soft) stool specimens collected from patients suspected of having C. difficile infection (CDI). OZN C. Difficile toxin gene amplification assay 2 Clostridium difficile (CDF) Stool Sample Preparation Kit
34 00840487101643 20-009-021 20-009-021 The Verigene® Gram-Negative Blood Culture Nucleic Acid Test (BC-GN) performed us The Verigene® Gram-Negative Blood Culture Nucleic Acid Test (BC-GN) performed using the sample-to-result Verigene® System, is a qualitative multiplexed in vitro diagnostic test for the simultaneous detection and identification of selected gram-negative bacteria and resistance markers. PEN Gram-Negative bacteria and associated resistance markers 2 Gram-Negative Blood Culture (BC-GN) Extraction Tray
35 00840487101278 3906-21 3906-21 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® CMV Primers
36 00840487101261 3906 3906 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® CMV Primers
37 00840487101230 3901 3901 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® Bordetella pertussis Primers
38 00840487101223 3900 3900 Nucleic acid sequences, which, through specific binding or chemical reaction wit Nucleic acid sequences, which, through specific binding or chemical reaction with substances in a specimen, are intended for use in a diagnostic application for identification and quantification of an individual chemical substance or ligand in biological specimens MVU REAGENTS,SPECIFIC,ANALYTE 1 MultiCode® HSV Primers
39 00840487100295 50-10017 The ARIES® HSV 1 & 2 Assay is a polymerase chain reaction (PCR)-based qualitativ The ARIES® HSV 1 & 2 Assay is a polymerase chain reaction (PCR)-based qualitative in vitro diagnostic test for the direct detection and differentiation of herpes simplex virus (HSV) DNA from cutaneous and mucocutaneous lesion swab specimens. PGI Herpes virus (VZV, HSV1, HSV2), DNA Detection Assay for cutaneous and mucocutane Herpes virus (VZV, HSV1, HSV2), DNA Detection Assay for cutaneous and mucocutaneous lesion samples 2 ARIES® HSV 1&2 Assay
40 00840487100097 40-50000 Sheath fluid is the delivery medium of the sample to the optics component. NSU Instrumentation for clinical multiplex test systems 2 xMAP® Sheath Fluid
41 00840487101674 20-011-018 20-011-018 The Verigene® Gram-Positive Blood Culture Nucleic Acid Test (BC-GP) performed us The Verigene® Gram-Positive Blood Culture Nucleic Acid Test (BC-GP) performed using the sample-to-result Verigene® System is a qualitative, multiplexed in vitro diagnostic test for the simultaneous detection and identification of potentially pathogenic gram-positive bacteria which may cause bloodstream infection (BSI). NQX,PAM SYSTEM, NUCLEIC ACID AMPLIFICATION TEST, DNA, METHICILLIN RESISTANT STAPHYLOCOCC SYSTEM, NUCLEIC ACID AMPLIFICATION TEST, DNA, METHICILLIN RESISTANT STAPHYLOCOCCUS AUREUS, DIRECT SPECIMEN,Gram-positive bacteria and their resistance markers 2 Gram-Positive Blood Culture (BC-GP) Utility Tray
42 00840487101599 20-006-021 20-006-021 The Verigene® Gram-Negative Blood Culture Nucleic Acid Test (BC-GN) performed us The Verigene® Gram-Negative Blood Culture Nucleic Acid Test (BC-GN) performed using the sample-to-result Verigene® System, is a qualitative multiplexed in vitro diagnostic test for the simultaneous detection and identification of selected gram-negative bacteria and resistance markers. PEN Gram-Negative bacteria and associated resistance markers 2 Gram-Negative Blood Culture (BC-GN) Nucleic Acid Test Cartridge
43 00840487101469 50-10041 The ARIES® Group A Strep Assay is a real-time polymerase chain reaction (PCR) ba The ARIES® Group A Strep Assay is a real-time polymerase chain reaction (PCR) based qualitative in vitro diagnostic test for the direct detection of Streptococcus pyogenes (Group A ß-hemolytic Streptococcus) in throat swab specimens from patients with signs and symptoms of pharyngitis. PGX,OOI Groups A, C and G beta-hemolytic streptococcus nucleic acid amplification system Groups A, C and G beta-hemolytic streptococcus nucleic acid amplification system,real time Nucleic acid amplification system 2 ARIES® Group A Strep Assay
44 00840487101421 MPXDF-4PK-1 The MAGPIX Drive Fluid serves as the delivery medium that carries the sample to The MAGPIX Drive Fluid serves as the delivery medium that carries the sample to the optics component of the MAGPIX instrument. NSU Instrumentation for clinical multiplex test systems 2 MAGPIX® Drive Fluid
45 00840487101032 3711 3711 The MultiCode®-RTx Herpes Simplex Virus 1 & 2 Kit is a polymerase chain reaction The MultiCode®-RTx Herpes Simplex Virus 1 & 2 Kit is a polymerase chain reaction (PCR)-based qualitative in vitro diagnostic test for the detection and typing of herpes simplex virus (HSV 1 & 2) DNA in vaginal lesions. It is indicated for use in the detection and typing of HSV-1 or HSV-2 in vaginal lesion swab specimens from symptomatic female patients as an aid in the diagnosis of genital herpes infection. OQO Herpes simplex virus nucleic acid amplification assay 2 Mutlicode®-RTx HSV 1&2 Kit
46 00840487100448 CN-SW47 The SYNCT Software is a desktop application that can be utilized by an end-user The SYNCT Software is a desktop application that can be utilized by an end-user on a standalone computer, providing users the ability to operate general functions such as Order Management, with or without a Laboratory Information System (LIS), viewing test results, reviewing and preparing test reports, performing software administrative functions, and providing security control for permitted functions. OOI real time Nucleic acid amplification system 2 SYNCT™ Software
47 00840487100325 10-0000-02 10-0000-02 The Verigene® Reader is the central control of the Verigene® System, a benchtop The Verigene® Reader is the central control of the Verigene® System, a benchtop molecular diagnostics workstation that utilizes patented gold nanoparticle technology to detect nucleic acid targets of interest for a variety of applications. OOI,NSU real time Nucleic acid amplification system,Instrumentation for clinical multipl real time Nucleic acid amplification system,Instrumentation for clinical multiplex test systems 2 Verigene® Reader
48 00840487100059 50-10018 The ARIES® C. difficile Assay is a real-time polymerase chain reaction (PCR) bas The ARIES® C. difficile Assay is a real-time polymerase chain reaction (PCR) based qualitative in vitro diagnostic test for the direct detection of Clostridium difficile (C. difficile) nucleic acid in unformed (liquid or soft) stool specimens obtained from patients suspected of having Clostridium difficile infection (CDI). OZN C.Difficile toxin gene amplification assay 2 ARIES® C. difficile Assay
49 00840487101728 30-001-001 30-001-001 The Verigene® Hypercoagulation Panel Nucleic Acid Test contains the Verigene® F The Verigene® Hypercoagulation Panel Nucleic Acid Test contains the Verigene® F5 Nucleic Acid Test, the Verigene® F2 Nucleic Acid Test and the Verigene® MTHFR Nucleic Acid Test. The Verigene® F5 Nucleic Acid Test is an in vitro diagnostic for the detection and genotyping of a single point mutation (G to A at position 1691; also known as Factor V Leiden) of the human Factor V gene (F5; Coagulation Factor V gene) in patients with suspected thrombophilia, from isolated genomic DNA obtained from whole blood samples. The Verigene® F2 Nucleic Acid Test is an in vitro diagnostic for the detection and genotyping of a single point mutation (G to A at position 20210) of the human Factor II gene (F2; prothrombin gene) in patients with suspected thrombophilia, from isolated genomic DNA obtained from whole blood samples. The Verigene® MTHFR Nucleic Acid Test is an in vitro diagnostic for the detection and genotyping of a single point mutation (C to T at position 677) of the human 5,10 methylenetetrahydrofolate reductase gene (MTHFR) in patients with suspected thrombophilia, from isolated genomic DNA obtained from whole blood samples. OMM,NPQ,NPR Test 5, 10-methylenetetrahydrofolate reductase mutations, genomic dna pcr,TEST, Test 5, 10-methylenetetrahydrofolate reductase mutations, genomic dna pcr,TEST, FACTOR V LEIDEN MUTATIONS, GENOMIC DNA PCR,TEST, FACTOR II G20210A MUTATIONS, GENOMIC DNA PCR 2 Hypercoagulation Panel (HC) Sample Buffer
50 00840487101537 ARIES M12V1 The ARIES® System is a clinical multiplex test system that automates and integra The ARIES® System is a clinical multiplex test system that automates and integrates extraction of nucleic acid from a clinical sample, performs real -time PCR, and measuring and sorting multiple signals generated in an in vitro diagnostic assay. OOI real time Nucleic acid amplification system 2 ARIES® System
Other products with the same Product Codes "OOI, NSU"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10190302059015 A32998 invitrogen LIFE TECHNOLOGIES, CORPORATION
2 10190302018449 A54626 QuantStudio™ 7 Pro Dx Software, V3.0.0 LIFE TECHNOLOGIES CORPORATION
3 10190302018159 A52649, V2.0.0 appliedbiosystems QuantStudioTM 7 Pro Dx Software LIFE TECHNOLOGIES CORPORATION
4 10190302018135 A54762 Diomni™ Software, V3.1.0 LIFE TECHNOLOGIES CORPORATION
5 10190302017978 A54068 SAE Admin Console Dx Software V1.2.0 Kit LIFE TECHNOLOGIES CORPORATION
6 10190302017961 A54067, V1.2.0 QuantStudio Dx Software V1.2.0, Kit LIFE TECHNOLOGIES CORPORATION
7 10190302017862 A52015, V1.0.5 QuantStudio™ 7 Pro Dx Software LIFE TECHNOLOGIES CORPORATION
8 10190302017701 A53120 DIOMNI SW V2.0.0 USB KIT LIFE TECHNOLOGIES CORPORATION
9 10190302017336 A51222 Applied Biosystems LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
10 10190302017329 A51220 Applied Biosystems LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
11 10190302017312 A52570, V1.1.0 SAE Admin Console Dx Software V1.1.0 Kit LIFE TECHNOLOGIES CORPORATION
12 10190302016964 A52440 384-Well Spectral Calibration Plate 2 LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
13 10190302016940 A52439 384-Well Spectral Calibration Plate 1 LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
14 10190302016162 A51197 QuantStudio™ 7 Pro Dx 96-Well Heated Cover LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
15 10190302016155 A51195 QuantStudio™ 7 Pro Dx 96-Well Block LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
16 10190302016148 A50745 QuantStudio™ 7 Pro Dx Real-Time PCR System LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
17 10190302015615 A48389 QuantStudio(TM) Dx Software Version 1.0.4 LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
18 10190302015592 A47324 Applied Biosystems™ QuantStudio™ 5 Dx Real-Time PCR System LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
19 10190302015554 A48166, V1.0.0 SAE Admin Console Dx Software V1.0 Kit LIFE TECHNOLOGIES CORPORATION
20 10190302015479 A47982, V1.0.0 QuantStudio Dx Software V1.1.0, Kit LIFE TECHNOLOGIES CORPORATION
21 10190302006736 1.0.1 QuantStudio Dx Emerging Pathogens Edition Software Version 1.0.1 LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
22 10190302006729 1.0.3 QuantStudio Dx Software V1.0.3, Kit LIFE TECHNOLOGIES CORPORATION
23 10190302003353 A31909 96-Well 0.2-mL Calibration Plate 3 (TAMRA, NED, and Cy 5 dyes) LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
24 10190302003124 A31908 96-Well 0.2-mL Calibration Plate 2 (ABY, JUN, and MUSTANG PURPLE dyes) LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
25 10190302001304 A31907 96-Well 0.2-mL Calibration Plate 1 (FAM, VIC, ROX, and SYBR dyes) LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
26 10190302000765 4481308 Fast 96-Well Background Calibration Plate LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
27 10190302000734 4480914 Lamp, Halogen RC, IVD LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
28 10190302000710 4478552 Fast 96-Well Spectral Calibration Plate with Cy®5 Dye LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
29 10190302000697 8788 QuantStudioTM Dx Real-Time PCR Instrument LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
30 10190302000611 7831 Fast 96-Well Heater Cover LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
31 10190302000598 7821 Fast 96-Well Block LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
32 10190302000505 4443774 Fast 96-Well Normalization Plates with FAM™/ROX™ and VIC™/ROX™ Dyes LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
33 10190302000468 4432656 Rnase P Fast 96-Well Instrument Verification Plate LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
34 10190302000437 4432638 Fast 96-Well Region of Interest (ROI) and Background Plates LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
35 10190302000420 4432632 Fast 96-Well Spectral Calibration Plate with TAMRA™ Dye LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
36 10190302000413 4432626 96-Well Region of Interst and Background Plates LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
37 10190302000390 4432614 Fast 96-Well Spectral Calibration Plate with ROX™ Dye LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
38 10190302000383 4432607 Fast 96-Well Spectral Calibration Plate with VIC™ Dye LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
39 10190302000376 4432600 Fast 96-Well Spectral Calibration Plate with FAM™ Dye LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
40 10190302000369 4432593 RNase P 96-Well Instrument Verification Plate LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
41 10190302000321 4432500 Rnase P Fast 384-Well Instrument Verification Plate LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
42 10190302000314 4432482 384-Well Region of Interest and Background Plates LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
43 10190302000222 7503 7500 Fast Dx Real-Time PCR  Instrument LIFE TECHNOLOGIES HOLDINGS PTE. LTD.
44 08885013950021 400125 400125 The Sentosa SA201 Real-Time PCR Instrument is a real-time nucleic acid amplifica The Sentosa SA201 Real-Time PCR Instrument is a real-time nucleic acid amplification and detection system. It measures nucleic acid signals from reverse transcribed RNA and converts the signals to comparative quantitative readouts using fluorescent detection of dual-labeled hydrolysis probes. Sentosa SA201 Real-Time PCR Instrument VELA OPERATIONS SINGAPORE PTE. LTD.
45 08809537070751 A-2061 A-2061 Exicycler™ 384 BIONEER CORPORATION
46 08809537070034 A-2060-1 A-2060-1 Exicycler™ 96 BIONEER CORPORATION
47 08800204300690 KM005 RADI PCR 96 Plus KH MEDICAL CO., LTD.
48 08800204300096 KM002 The RADI CHAMP260 is a stand-alone automated isothermal amplification and detec The RADI CHAMP260 is a stand-alone automated isothermal amplification and detection system for target nucleic acid sequences found in human specimens. The instrument is used in conjunction with KH Medical’s LOOP-Mediated Amplification in vitro diagnostic products.RADI CHAMP260 is designed to freely manipulate specific temperature and running time for amplification of samples by 7 inch touch screen.Amplification of target DNA occurs during the heat cycle and results in the formation of precipitate detected by the RADI CHAMP260 optics system. The precipitate generated by the presence of amplified target DNA leads to a turbid Sample/Control reaction solution which is then measured by absorbance. The RADI CHAMP260 uses the change in turbidity of each Sample/Control reaction solution to report assay results as INVALID, POSITIVE, or NEGATIVE on the 7 inch touch screen. RADI CHAMP260 KH MEDICAL CO., LTD.
49 08430793040532 724120 1. Aptiva Celiac Disease IgA Reagent Cartridge contains reagents to process 250 1. Aptiva Celiac Disease IgA Reagent Cartridge contains reagents to process 250 samples.a. tTG, DGP, and Control paramagnetic particles, preserved. b. Assay Buffer – colored pink, containing protein stabilizers and preservatives.c. PE Tracer IgA – PE labeled anti-human IgA antibody, containing buffer, protein stabilizers and preservative.d. Rehydration Buffer - containing protein stabilizers and preservatives Aptiva® Celiac Disease IgA Reagent INOVA DIAGNOSTICS, INC.
50 08430215046203 03531414001 03531414001 LightCycler® 2.0 Instrument ROCHE MOLECULAR SYSTEMS, INC.