DSA-Cabinet; Manifold; Series 3316; DSAC-M2-3316-TSI-R; TRICOR Label; Refurbishe
DSA-Cabinet; Manifold; Series 3316; DSAC-M2-3316-TSI-R; TRICOR Label; Refurbished;Dri-Scope Aid - Cabinet refurbished system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 33” wide / 16 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2R) - Series 3316 - Refurbished
DSA-Cabinet; Manifold; Series 3308; DSAC-M2-3308-TSI-R; TRICOR Label; Refurbishe
DSA-Cabinet; Manifold; Series 3308; DSAC-M2-3308-TSI-R; TRICOR Label; Refurbished;Dri-Scope Aid - Cabinet refurbished system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 33” wide / 8 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2R) - Series 3308 - Refurbished
DSA-Cabinet; Manifold; Series 2310; DSAC-M2-2310-TSI-R; TRICOR Label; Refurbishe
DSA-Cabinet; Manifold; Series 2310; DSAC-M2-2310-TSI-R; TRICOR Label; Refurbished;Dri-Scope Aid - Cabinet refurbished system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 23” wide / 10 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2R) - Series 2310 - Refurbished
Dri-Scope Aid - Cabinet refurbished system is intended to aid in drying and vent
Dri-Scope Aid - Cabinet refurbished system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 23” wide / 5 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2R) - Series 2305 - Refurbished
Dri-Scope Aid-Cabinet; Pump Wall BL1; Series 1840; DSAC-PW3-MOB; TRICOR Label;Dr
Dri-Scope Aid-Cabinet; Pump Wall BL1; Series 1840; DSAC-PW3-MOB; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system. Note: this system has been programmed to accept external software commands and/or remote monitoring via Mobile Aspects proprietary hardware and software.
Dri-Scope Aid - Cabinet - Pump Wall (P3) - Series 1840 - Mobile Aspects
Dri-Scope Aid-Cabinet [Gen 2]; Manifold; Series 3316; DSC2-M1-3316-TSI; TRICOR L
Dri-Scope Aid-Cabinet [Gen 2]; Manifold; Series 3316; DSC2-M1-3316-TSI; TRICOR Label;Dri-Scope Aid - Cabinet Gen 2 system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 33” wide / 16 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - [Gen 2] Cabinet - Manifold (M1) - Series 3316
Dri-Scope Aid-Cabinet [Gen 2]; Manifold; Series 3308; DSC2-M1-3308-TSI; TRICOR L
Dri-Scope Aid-Cabinet [Gen 2]; Manifold; Series 3308; DSC2-M1-3308-TSI; TRICOR Label;Dri-Scope Aid - Cabinet Gen 2 system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 33” wide / 8 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - [Gen 2] Cabinet - Manifold (M1) - Series 3308
Dri-Scope Aid-Cabinet [Gen 2]; Manifold; Series 2310; DSC2-M1-2310-TSI; TRICOR L
Dri-Scope Aid-Cabinet [Gen 2]; Manifold; Series 2310; DSC2-M1-2310-TSI; TRICOR Label;Dri-Scope Aid - Cabinet Gen 2 system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 23” wide / 10 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - [Gen 2] Cabinet - Manifold (M1) - Series 2310
Dri-Scope Aid-Cabinet [Gen 2]; Manifold; Series 2305; DSC2-M1-2305-TSI; TRICOR L
Dri-Scope Aid-Cabinet [Gen 2]; Manifold; Series 2305; DSC2-M1-2305-TSI; TRICOR Label;Dri-Scope Aid - Cabinet Gen 2 system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 23” wide / 5 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - [Gen 2] Cabinet - Manifold (M1) - Series 2305
Dri-Scope Aid-Cabinet [Gen 2]; Regulator Ceiling; Series 1840; DSC2-RC3-TSI; TRI
Dri-Scope Aid-Cabinet [Gen 2]; Regulator Ceiling; Series 1840; DSC2-RC3-TSI; TRICOR Label;Dri-Scope Aid - Cabinet Gen 2 system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted regulator version is one component of the Dri-Scope Aid – Cabinet system that contains a precision regulator used to provide HEPA filtered air to other parts of the system from an external medical air source. This regulator component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - [Gen 2] Cabinet - Regulator Ceiling (R3) - Series 1840
Dri-Scope Aid-Cabinet [Gen 2]; Regulator Wall; Series 1840; DSC2-RW3-TSI; TRICOR
Dri-Scope Aid-Cabinet [Gen 2]; Regulator Wall; Series 1840; DSC2-RW3-TSI; TRICOR Label;Dri-Scope Aid - Cabinet Gen 2 system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted regulator version is one component of the Dri-Scope Aid – Cabinet system that contains a precision regulator used to provide HEPA filtered air to other parts of the system from an external medical air source. This regulator component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - [Gen 2] Cabinet - Regulator Wall (R3) - Series 1840
Dri-Scope Aid-Cabinet [Gen 2]; Pump Ceiling BL1; Series 1840; DSC2-PC3-TSI; TRIC
Dri-Scope Aid-Cabinet [Gen 2]; Pump Ceiling BL1; Series 1840; DSC2-PC3-TSI; TRICOR Label;Dri-Scope Aid - Cabinet Gen 2 system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - [Gen 2] Cabinet - Pump Ceiling (P3) - Series 1840
Dri-Scope Aid-Cabinet [Gen 2]; Pump Wall BL1; Series 1840; DSC2-PW3-TSI; TRICOR
Dri-Scope Aid-Cabinet [Gen 2]; Pump Wall BL1; Series 1840; DSC2-PW3-TSI; TRICOR Label;Dri-Scope Aid - Cabinet Gen 2 system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - [Gen 2] Cabinet - Pump Wall (P3) - Series 1840
Dri-Scope Aid-Jet Stream; Regulator; Model 1840R; DSA3-R2-TSI; TRICOR Label;The
Dri-Scope Aid-Jet Stream; Regulator; Model 1840R; DSA3-R2-TSI; TRICOR Label;The Dri-Scope Aid Jet-Stream (Model 1840R) is a counter-top (or pole/wall mounted) device designed to assist in the drying of internal channels of an endoscope at the point of cleaning. The device's internal pressure regulator provides and distributes a constant flow of 0.1um HEPA-filtered externally supplied medical air to aid in the drying process after high-level cleaning and disinfecting. Dual-port, dual-timer allows one (or two) endoscopes to be connected simultaneously for drying. The device provides precision regulated air as well as air filter performance monitoring to assure proper pressure and air flow.
Dri-Scope Aid-Cabinet; Pump Ceiling; Series 1840; DSAC-PC2-MOB; TRICOR Label;Dri
Dri-Scope Aid-Cabinet; Pump Ceiling; Series 1840; DSAC-PC2-MOB; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. Note: this system has been programmed to accept external software commands and/or remote monitoring via Mobile Aspects proprietary hardware and software.
Dri-Scope Aid-Cabinet; Pump Ceiling; Series 1840; DSAC-PC2-MOB; TRICOR Label;
Dri-Scope Aid-Cabinet; Pump Wall; Series 1840; DSAC-PW2-MOB; TRICOR Label;Dri-Sc
Dri-Scope Aid-Cabinet; Pump Wall; Series 1840; DSAC-PW2-MOB; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. Note: this system has been programmed to accept external software commands and/or remote monitoring via Mobile Aspects proprietary hardware and software.
Dri-Scope Aid - Cabinet - Pump Wall (P2) - Series 1840 - Mobile Aspects
Dri-Scope Aid-Cabinet; Pump Ceiling BL2; Series 1840; DSAC-PC4-TSI; TRICOR Label
Dri-Scope Aid-Cabinet; Pump Ceiling BL2; Series 1840; DSAC-PC4-TSI; TRICOR Label; Refurbished;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system. This component has been refurbished to a condition of safety and effectiveness that is comparable to when new.
Dri-Scope Aid - Cabinet - Pump Ceiling (P4R) - Series 1840
Dri-Scope Aid-Cabinet; Pump Ceiling BL1; Series 1840; DSAC-PC3-TSI; TRICOR Label
Dri-Scope Aid-Cabinet; Pump Ceiling BL1; Series 1840; DSAC-PC3-TSI; TRICOR Label; Refurbished;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system. This component has been refurbished to a condition of safety and effectiveness that is comparable to when new.
Dri-Scope Aid - Cabinet - Pump Ceiling (P3R) - Series 1840
Dri-Scope Aid-Cabinet; Pump Wall BL2; Series 1840; DSAC-PW4-TSI; TRICOR Label; R
Dri-Scope Aid-Cabinet; Pump Wall BL2; Series 1840; DSAC-PW4-TSI; TRICOR Label; Refurbished;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system. This pump component has been refurbished to a condition of safety and effectiveness that is comparable to when new.
Dri-Scope Aid - Cabinet - Pump Wall (P4R) - Series 1840
Dri-Scope Aid-Cabinet; Pump Wall BL1; Series 1840; DSAC-PW3-TSI; TRICOR Label; R
Dri-Scope Aid-Cabinet; Pump Wall BL1; Series 1840; DSAC-PW3-TSI; TRICOR Label; Reburbished;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system. This pump component has been refurbished to a condition of safety and effectiveness that is comparable to when new.
Dri-Scope Aid - Cabinet - Pump Wall (P3R) - Series 1840
Dri-Scope Aid-Cabinet; Pump Ceiling BL2; Series 1840; DSAC-PC4-SLR; Solaire Labe
Dri-Scope Aid-Cabinet; Pump Ceiling BL2; Series 1840; DSAC-PC4-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system.
Dri-Scope Aid - Cabinet - Pump Ceiling (P4) - Series 1840 - Solaire
Dri-Scope Aid-Cabinet; Pump Ceiling BL1; Series 1840; DSAC-PC3-SLR; Solaire Labe
Dri-Scope Aid-Cabinet; Pump Ceiling BL1; Series 1840; DSAC-PC3-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system.
Dri-Scope Aid - Cabinet - Pump Ceiling (P3) - Series 1840 - Solaire
Dri-Scope Aid-Cabinet; Pump Wall BL2; Series 1840; DSAC-PW4-SLR; Solaire Label;D
Dri-Scope Aid-Cabinet; Pump Wall BL2; Series 1840; DSAC-PW4-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system.
Dri-Scope Aid - Cabinet - Pump Wall (P4) - Series 1840 - Solaire
Dri-Scope Aid-Cabinet; Pump Wall BL1; Series 1840; DSAC-PW3-SLR; Solaire Label;D
Dri-Scope Aid-Cabinet; Pump Wall BL1; Series 1840; DSAC-PW3-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system.
Dri-Scope Aid - Cabinet - Pump Wall (P3) - Series 1840 - Solaire
Dri-Scope Aid-Cabinet; Regulator Ceiling; Series 1840; DSAC-RC2-TSI; TRICOR Labe
Dri-Scope Aid-Cabinet; Regulator Ceiling; Series 1840; DSAC-RC2-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted regulator version is one component of the Dri-Scope Aid – Cabinet system that contains a precision regulator used to provide HEPA filtered air to other parts of the system from an external medical air source. This regulator component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - Cabinet - Regulator Ceiling (R2) - Series 1840
Dri-Scope Aid-Cabinet; Regulator Wall; Series 1840; DSAC-RW2-TSI; TRICOR Label;D
Dri-Scope Aid-Cabinet; Regulator Wall; Series 1840; DSAC-RW2-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted regulator version is one component of the Dri-Scope Aid – Cabinet system that contains a precision regulator used to provide HEPA filtered air to other parts of the system from an external medical air source. This regulator component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - Cabinet - Regulator Wall (R2) - Series 1840
Dri-Scope Aid-Cabinet; Pump Ceiling BL2; Series 1840; DSAC-PC4-TSI; TRICOR Label
Dri-Scope Aid-Cabinet; Pump Ceiling BL2; Series 1840; DSAC-PC4-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - Cabinet - Pump Ceiling (P4) - Series 1840
Dri-Scope Aid-Cabinet; Pump Ceiling BL1; Series 1840; DSAC-PC3-TSI; TRICOR Label
Dri-Scope Aid-Cabinet; Pump Ceiling BL1; Series 1840; DSAC-PC3-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - Cabinet - Pump Ceiling (P3) - Series 1840
Dri-Scope Aid-Cabinet; Pump Wall BL2; Series 1840; DSAC-PW4-TSI; TRICOR Label;Dr
Dri-Scope Aid-Cabinet; Pump Wall BL2; Series 1840; DSAC-PW4-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - Cabinet - Pump Wall (P4) - Series 1840
Dri-Scope Aid-Cabinet; Pump Wall BL1; Series 1840; DSAC-PW3-TSI; TRICOR Label;Dr
Dri-Scope Aid-Cabinet; Pump Wall BL1; Series 1840; DSAC-PW3-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - Cabinet - Pump Wall (P3) - Series 1840
Dri-Scope Aid-Jet Stream; Pump BL2; Model 1840P; DSA3-P3-TSI; TRICOR Label;The D
Dri-Scope Aid-Jet Stream; Pump BL2; Model 1840P; DSA3-P3-TSI; TRICOR Label;The Dri-Scope Aid Jet-Stream (Model 1840P) is a counter-top (or pole/wall mounted) device designed to assist in the drying of internal channels of an endoscope at the point of cleaning. The device's internal pump provides a constant flow of 0.1um HEPA-filtered air to aid in the drying process after high-level cleaning and disinfecting has been done. Dual-port, dual-timer allows one (or two) endoscopes to be connected simultaneously for drying. The programmable device provides automatic high pressure shutoff protection as well as air filter performance monitoring to assure proper pressure and air flow.
Dri-Scope Aid-Jet Stream; Pump BL1; Model 1840P; DSA3-P2-TSI; TRICOR Label;The D
Dri-Scope Aid-Jet Stream; Pump BL1; Model 1840P; DSA3-P2-TSI; TRICOR Label;The Dri-Scope Aid Jet-Stream (Model 1840P) is a counter-top (or pole/wall mounted) device designed to assist in the drying of internal channels of an endoscope at the point of cleaning. The device's internal pump provides a constant flow of 0.1um HEPA-filtered air to aid in the drying process after high-level cleaning and disinfecting has been done. Dual-port, dual-timer allows one (or two) endoscopes to be connected simultaneously for drying. The programmable device provides automatic high pressure shutoff protection as well as air filter performance monitoring to assure proper pressure and air flow.
Dri-Scope Aid-Cabinet; Pump Ceiling; Series 1840; DSAC-PC2-TSI-R; TRICOR Label;
Dri-Scope Aid-Cabinet; Pump Ceiling; Series 1840; DSAC-PC2-TSI-R; TRICOR Label; Refurbished;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system. This component has been refurbished to a condition of safety and effectiveness that is comparable to when new.
Dri-Scope Aid - Cabinet - Pump Ceiling (P2R) - Series 1840
Dri-Scope Aid-Cabinet; Pump Wall; Series 1840; DSAC-PW2-TSI-R; TRICOR Label; Ref
Dri-Scope Aid-Cabinet; Pump Wall; Series 1840; DSAC-PW2-TSI-R; TRICOR Label; Refurbished;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet (DSAC) system that contains an internal pump used to provide HEPA filtered air to the DSAC system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system. This pump component has been refurbished to a condition of safety and effectiveness that is comparable to when new.
Dri-Scope Aid - Cabinet - Pump Wall (P2R) - Series 1840
Dri-Scope Aid-Cabinet; Manifold; Series 3316; DSAC-M2-3316-SLR; Solaire Label;Dr
Dri-Scope Aid-Cabinet; Manifold; Series 3316; DSAC-M2-3316-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) 33” wide / 16 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2) - Series 3316 - Solaire
Dri-Scope Aid-Cabinet; Manifold; Series 3308; DSAC-M2-3308-SLR; Solaire Label;Dr
Dri-Scope Aid-Cabinet; Manifold; Series 3308; DSAC-M2-3308-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) 33” wide / 8 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2) - Series 3308 - Solaire
Dri-Scope Aid-Cabinet; Manifold; Series 2310; DSAC-M2-2310-SLR; Solaire Label;Dr
Dri-Scope Aid-Cabinet; Manifold; Series 2310; DSAC-M2-2310-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) 23” wide / 10 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2) - Series 2310 - Solaire
Dri-Scope Aid-Cabinet; Manifold; Series 2305; DSAC-M2-2305-SLR; Solaire Label;Dr
Dri-Scope Aid-Cabinet; Manifold; Series 2305; DSAC-M2-2305-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) 23” wide / 5 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2) - Series 2305 - Solaire
Dri-Scope Aid-Cabinet; Pump Ceiling; Series 1840; DSAC-PC2-SLR; Solaire Label;Dr
Dri-Scope Aid-Cabinet; Pump Ceiling; Series 1840; DSAC-PC2-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system.
Dri-Scope Aid - Cabinet - Pump Ceiling (P2) - Series 1840 - Solaire
Dri-Scope Aid-Cabinet; Pump Wall; Series 1840; DSAC-PW2-SLR; Solaire Label;Dri-S
Dri-Scope Aid-Cabinet; Pump Wall; Series 1840; DSAC-PW2-SLR; Solaire Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / SOLAIRE Medical - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system.
Dri-Scope Aid - Cabinet - Pump Wall (P2) - Series 1840 - Solaire
Dri-Scope Aid-Cabinet; Manifold; Series 3316; DSAC-M2-3316-TSI; TRICOR Label;Dri
Dri-Scope Aid-Cabinet; Manifold; Series 3316; DSAC-M2-3316-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 33” wide / 16 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2) - Series 3316
Dri-Scope Aid-Cabinet; Manifold; Series 3308; DSAC-M2-3308-TSI; TRICOR Label;Dri
Dri-Scope Aid-Cabinet; Manifold; Series 3308; DSAC-M2-3308-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 33” wide / 8 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2) - Series 3308
Dri-Scope Aid-Cabinet; Manifold; Series 2310; DSAC-M2-2310-TSI; TRICOR Label;Dri
Dri-Scope Aid-Cabinet; Manifold; Series 2310; DSAC-M2-2310-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 23” wide / 10 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2) - Series 2310
Dri-Scope Aid-Cabinet; Manifold; Series 2305; DSAC-M2-2305-TSI; TRICOR Label;Dri
Dri-Scope Aid-Cabinet; Manifold; Series 2305; DSAC-M2-2305-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis around the clock. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) 23” wide / 5 port manifold is one component of the Dri-Scope Aid – Cabinet system that receives the HEPA filtered air from the system pump and distributes it to the endoscope(s) for the purpose of drying and venting.
Dri-Scope Aid - Cabinet - Manifold (M2) - Series 2305
Dri-Scope Aid-Cabinet; Pump Ceiling; Series 1840; DSAC-PC2-TSI; TRICOR Label;Dri
Dri-Scope Aid-Cabinet; Pump Ceiling; Series 1840; DSAC-PC2-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) ceiling-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - Cabinet - Pump Ceiling (P2) - Series 1840
Dri-Scope Aid-Cabinet; Pump Wall; Series 1840; DSAC-PW2-TSI; TRICOR Label;Dri-Sc
Dri-Scope Aid-Cabinet; Pump Wall; Series 1840; DSAC-PW2-TSI; TRICOR Label;Dri-Scope Aid - Cabinet system is intended to aid in drying and venting internal channels of cleaned and disinfected endoscopes. The system is designed to cost-effectively convert existing passive cabinets (or closets) to active drying cabinets (or closets). The system can process as many as 16 endoscopes that are waiting in the queue. It provides pressure sensitive continuous flow of clean HEPA filtered air. Simply attach the endoscope, press the button to place the endoscope in the processing queue and the system will take care of the rest. After the drying cycle is complete, the system will periodically cycle dry air through the endoscope internal channels on a timed basis indefinitely until the endoscope is removed from the system. This (TRICOR Systems Inc - built / TRICOR Systems Inc - labeled) wall-mounted pump version is one component of the Dri-Scope Aid – Cabinet system that contains an internal pump used to provide HEPA filtered air to other parts of the system. This pump component is used along with 2 (or 1) of the Dri-Scope Aid - Manifolds which together works as a drying system.
Dri-Scope Aid - Cabinet - Pump Wall (P2) - Series 1840
Dri-Scope Aid-Jet Stream; Regulator; Model 1840R; DSA3-R1-TSI; TRICOR Label;The
Dri-Scope Aid-Jet Stream; Regulator; Model 1840R; DSA3-R1-TSI; TRICOR Label;The Dri-Scope Aid Jet-Stream (Model 1840R) is a counter-top (or pole/wall mounted) device designed to assist in the drying of internal channels of an endoscope at the point of cleaning. The device's internal pressure regulator provides and distributes a constant flow of 0.1um HEPA-filtered externally supplied medical air to aid in the drying process after high-level cleaning and disinfecting. Dual-port, dual-timer allows one (or two) endoscopes to be connected simultaneously for drying. The device provides precision regulated air as well as air filter performance monitoring to assure proper pressure and air flow.
Dri-Scope Aid-Jet Stream; Pump; Model 1840P; DSA3-P1-TSI; TRICOR Label;The Dri-S
Dri-Scope Aid-Jet Stream; Pump; Model 1840P; DSA3-P1-TSI; TRICOR Label;The Dri-Scope Aid Jet-Stream (Model 1840P) is a counter-top (or pole/wall mounted) device designed to assist in the drying of internal channels of an endoscope at the point of cleaning. The device's internal pump provides a constant flow of 0.1um HEPA-filtered air to aid in the drying process after high-level cleaning and disinfecting has been done. Dual-port, dual-timer allows one (or two) endoscopes to be connected simultaneously for drying. The programmable device provides automatic high pressure shutoff protection as well as air filter performance monitoring to assure proper pressure and air flow.