Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
SMART STAPES PISTON 04MM X 525MM TRIMMABLE TO 35MM NITINOL FLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
RICHARDS BUCKET HANDLE 10 MM WELL ID 6 MM DIA 425 MM LONG TITANIUM
Means of reconstruction of natural or surgically created defects of the mastoid
Means of reconstruction of natural or surgically created defects of the mastoid lining the canal wall or the attic of the tympanic cavity
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
DE LA CRUZ PISTON 06MM DIA 425MM LENGTH PLATINUMFLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process.
ETB
Prosthesis, Partial Ossicular Replacement
2
DORNHOFFER MICRON FOOTPLATE SHOE FOR USE WITH 9MM TITANIUM SHAFT TITANIUM
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
SMART 360 STAPES PISTON 05MM X 425MM NITINOL FLUOROPLASTIC CIRCUMFERENTIAL
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
RICHARDS PISTON 45 MM LENGTH 8MM DIAMETER PLATINUM FLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
RICHARDS PISTON 50 MM LENGTH 6MM DIAMETER PLATINUM FLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
RICHARDS PISTON 45 MM LENGTH 6MM DIAMETER PLATINUM FLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
APPLEBAUM INCUS REPLACEMENT 35 MM DENSE HYDROXYLAPATITE
The Shaver 2.1mm Single Use Double Serrated Straight Blade is used with the Sha
The Shaver 2.1mm Single Use Double Serrated Straight Blade is used with the Shaver System. The blade is for single use and is supplied sterile. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
Shaver Blade 2.1mm Single Use Double Serrated Straight
The Shaver 4mm Single Use Double Serrated 60 Degree Blade is used with the Shave
The Shaver 4mm Single Use Double Serrated 60 Degree Blade is used with the Shaver System. The blade is for single use and is supplied sterile. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
Shaver Blade 4mm Single Use Double Serrated 60 Degree
The Shaver 4mm Single Use Double Serrated 40 Degree Blade is used with the Shave
The Shaver 4mm Single Use Double Serrated 40 Degree Blade is used with the Shaver System. The blade is for single use and is supplied sterile. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
Shaver Blade 4mm Single Use Double Serrated 40 Degree
The Shaver 4mm Single Use Double Serrated Straight Blade is used with the Shaver
The Shaver 4mm Single Use Double Serrated Straight Blade is used with the Shaver System. The blade is for single use and is supplied sterile. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
Shaver Blade 4mm Single Use Double Serrated Straight
The Shaver 3mm Single Use Double Serrated 60 Degree Blade is used with the Shave
The Shaver 3mm Single Use Double Serrated 60 Degree Blade is used with the Shaver System. The blade is for single use and is supplied sterile. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
Shaver Blade 3mm Single Use Double Serrated 60 Degree
The Shaver 3mm Single Use Double Serrated 40 Degree Blade is used with the Shave
The Shaver 3mm Single Use Double Serrated 40 Degree Blade is used with the Shaver System. The blade is for single use and is supplied sterile. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
Shaver Blade 3mm Single Use Double Serrated 40 Degree
The Shaver 3mm Single Use Double Serrated Straight Blade is used with the Shaver
The Shaver 3mm Single Use Double Serrated Straight Blade is used with the Shaver System. The blade is for single use and is supplied sterile. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
Shaver Blade 3mm Single Use Double Serrated Straight
The Shaver 4mm Reusable Double Serrated Straight Blade is used with the Shaver
The Shaver 4mm Reusable Double Serrated Straight Blade is used with the Shaver System. The blade is a reusable device supplied sterile and requires reprocessing (cleaning, lubrication and sterilization) after the initial use. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
The Shaver 3mm Reusable Double Serrated Straight Blade is used with the Shaver S
The Shaver 3mm Reusable Double Serrated Straight Blade is used with the Shaver System. The blade is a reusable device supplied sterile and requires reprocessing (cleaning, lubrication and sterilization) after the initial use. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
The Shaver 2.1mm Reusable Double Serrated Straight Blade is used with the Shaver
The Shaver 2.1mm Reusable Double Serrated Straight Blade is used with the Shaver System. The blade is a reusable device supplied sterile and requires reprocessing (cleaning, lubrication and sterilization) after the initial use. The Shaver System shapes bone and resects soft and hard tissues in the areas of otorhinolaryngology.
DragonFly™ EGG CUTTING BUR 80MM LENGTH, 2.3MM Ø WITH BurShield™ - USED WITH 950-
DragonFly™ EGG CUTTING BUR 80MM LENGTH, 2.3MM Ø WITH BurShield™ - USED WITH 950-002 HANDPIECE
DragonFly™ ROUND CUTTING BUR 80MM LENGTH, 0.4MM Ø WITH BurShield™ - USED WITH 95
DragonFly™ ROUND CUTTING BUR 80MM LENGTH, 0.4MM Ø WITH BurShield™ - USED WITH 950-002 HANDPIECE
DragonFly™ ROUND DIAMOND BUR 95MM LENGTH, 2.3MM Ø WITH BurShield™ - USED WITH 95
DragonFly™ ROUND DIAMOND BUR 95MM LENGTH, 2.3MM Ø WITH BurShield™ - USED WITH 950-002 HANDPIECE
DragonFly™ ROUND DIAMOND BUR 95MM LENGTH, 1.8MM Ø WITH BurShield™ - USED WITH 95
DragonFly™ ROUND DIAMOND BUR 95MM LENGTH, 1.8MM Ø WITH BurShield™ - USED WITH 950-002 HANDPIECE