Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
SMART STAPES PISTON 04MM X 525MM TRIMMABLE TO 35MM NITINOL FLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
RICHARDS BUCKET HANDLE 10 MM WELL ID 6 MM DIA 425 MM LONG TITANIUM
Means of reconstruction of natural or surgically created defects of the mastoid
Means of reconstruction of natural or surgically created defects of the mastoid lining the canal wall or the attic of the tympanic cavity
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
DE LA CRUZ PISTON 06MM DIA 425MM LENGTH PLATINUMFLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process.
ETB
Prosthesis, Partial Ossicular Replacement
2
DORNHOFFER MICRON FOOTPLATE SHOE FOR USE WITH 9MM TITANIUM SHAFT TITANIUM
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
SMART 360 STAPES PISTON 05MM X 425MM NITINOL FLUOROPLASTIC CIRCUMFERENTIAL
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
RICHARDS PISTON 45 MM LENGTH 8MM DIAMETER PLATINUM FLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
RICHARDS PISTON 50 MM LENGTH 6MM DIAMETER PLATINUM FLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
RICHARDS PISTON 45 MM LENGTH 6MM DIAMETER PLATINUM FLUOROPLASTIC
Replace the portion of the ossicular chain that has lost its function due to dis
Replace the portion of the ossicular chain that has lost its function due to disease congenital defect or other pathological process
ETB
Prosthesis, Partial Ossicular Replacement
2
APPLEBAUM INCUS REPLACEMENT 35 MM DENSE HYDROXYLAPATITE
The device is used to evacuate the contents of the uterus. Aspirator is double-v
The device is used to evacuate the contents of the uterus. Aspirator is double-valve, and consists of a 60cc syringe barrel, plunger, collar stop, o-ring, and a removable valve liner. Aspirators are clean, sterile, and single use.
The device is used to evacuate the contents of the uterus. It consists of a 60cc
The device is used to evacuate the contents of the uterus. It consists of a 60cc syringe barrel, plunger, collar stop, o-ring, and removable valve liner. Aspirators are compatible with cannulae size 3-6mm. Aspirator is sterile, clean, and single use.
Accessory kits are bagged and each kit contains: collar stop, plunger, o-ring an
Accessory kits are bagged and each kit contains: collar stop, plunger, o-ring and 2cc silicone tube. The cap, collar stop and o-ring, as components, are suitable to be reused a maximum of 25 times.
WomanCare Global Single-Valve Aspirator Accessory Kit
Accessory Kits are packed in a sealed bag containing one cap, one collar stop, o
Accessory Kits are packed in a sealed bag containing one cap, one collar stop, one O-ring, and one 2cc tube of silicone. The cap, collar stop and O-ring as components are suitable to be reused a maximum of 25 times.
WomanCare Global Ipas MVA Plus® Aspirator Accessory Kit
Each kit contains one Ipas Double-Valve Aspirator, 4 Ipas EasyGrip® Cannulae : 6
Each kit contains one Ipas Double-Valve Aspirator, 4 Ipas EasyGrip® Cannulae : 6mm, 7mm, 8mm and 9 mm, 3 Denniston Dilators: 5/6mm, 7/8mm and 9/10 mm.
The device is used to evacuate the contents of the uterus. It consists of a 60cc
The device is used to evacuate the contents of the uterus. It consists of a 60cc syringe barrel, plunger, collar stop, and removable valve liner. Aspirators are compatible with cannulae size 3-6mm. Aspirators are clean, not sterile, and reusable.
The device is used to evacuate the contents of the uterus, or to obtain specimen
The device is used to evacuate the contents of the uterus, or to obtain specimens for pathological examination. The aspirator consists of a 60cc syringe barrel (with graduations), plastic plunger with an ergonomically-designed handle, a plunger, a rubber o-ring, a collar stop, a plastic double-locking valve with removable silicone liner, and valve cover. Aspirators are clean, not sterile, and reusable at a maximum of 25 times. The package contains one aspirator and one 2cc silicone tube.
The device is used to evacuate the contents of the uterus. The aspirator is doub
The device is used to evacuate the contents of the uterus. The aspirator is double-valve, consisting of a 60cc syringe barrel, plunger, collar stop, and removable valve liner. Aspirators are clean, not sterile, and single-use.