Other products from "IN2BONES USA, LLC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00810021863603 P43 ST238 CoLink® VAL Screw, Ø3.0 X 38mm HWC Screw, Fixation, Bone 2 CoLink® 2
2 00810021863610 P43 ST240 CoLink® VAL Screw, Ø3.0 X 40mm HWC Screw, Fixation, Bone 2 CoLink® 2
3 00810021863597 P43 ST236 CoLink® VAL Screw, Ø3.0 X 36mm HWC Screw, Fixation, Bone 2 CoLink® 2
4 00810021863573 P43 ST232 CoLink® VAL Screw, Ø3.0 X 32mm HWC Screw, Fixation, Bone 2 CoLink® 2
5 00810021863566 P43 ST230 CoLink® VAL Screw, Ø3.0 X 30mm HWC Screw, Fixation, Bone 2 CoLink® 2
6 00810021863559 P43 ST228 CoLink® VAL Screw, Ø3.0 X 28mm HWC Screw, Fixation, Bone 2 CoLink® 2
7 00810021863542 P43 ST226 CoLink® VAL Screw, Ø3.0 X 26mm HWC Screw, Fixation, Bone 2 CoLink® 2
8 00810021863535 P43 ST224 CoLink® VAL Screw, Ø3.0 X 24mm HWC Screw, Fixation, Bone 2 CoLink® 2
9 00810021863528 P43 ST222 CoLink® VAL Screw, Ø3.0 X 22mm HWC Screw, Fixation, Bone 2 CoLink® 2
10 00810021863511 P43 ST220 CoLink® VAL Screw, Ø3.0 X 20mm HWC Screw, Fixation, Bone 2 CoLink® 2
11 00810021863504 P43 ST218 CoLink® VAL Screw, Ø3.0 X 18mm HWC Screw, Fixation, Bone 2 CoLink® 2
12 00810021863498 P43 ST216 CoLink® VAL Screw, Ø3.0 X 16mm HWC Screw, Fixation, Bone 2 CoLink® 2
13 00817906027884 P72 ST250 VAL SCREW, Ø2.7X50MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
14 00817906027877 P72 ST247 VAL SCREW, Ø2.7X47.5MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
15 00817906027860 P72 ST245 VAL SCREW, Ø2.7X45MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
16 00817906027853 P72 ST242 VAL SCREW, Ø2.7X42.5MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
17 00817906027839 P72 ST237 VAL SCREW, Ø2.7X37.5MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
18 00817906027822 P72 ST235 VAL SCREW, Ø2.7X35MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
19 00817906027815 P72 ST232 VAL SCREW, Ø2.7X32.5MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
20 00817906027808 P72 ST230 VAL SCREW, Ø2.7X30MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
21 00817906027792 P72 ST228 VAL SCREW, Ø2.7X28MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
22 00817906027785 P72 ST226 VAL SCREW, Ø2.7X26MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
23 00817906027778 P72 ST224 VAL SCREW, Ø2.7X24MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
24 00817906027761 P72 ST222 VAL SCREW, Ø2.7X22MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
25 00817906027754 P72 ST220 VAL SCREW, Ø2.7X20MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
26 00817906027747 P72 ST218 VAL SCREW, Ø2.7X18MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
27 00817906027730 P72 ST216 VAL SCREW, Ø2.7X16MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
28 00817906027723 P72 ST214 VAL SCREW, Ø2.7X14MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
29 00817906027716 P72 ST212 VAL SCREW, Ø2.7X12MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
30 00817906027709 P72 ST210 VAL SCREW, Ø2.7X10MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
31 00817906027693 P72 ST208 VAL SCREW, Ø2.7X8MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
32 00817906027686 P72 ST150 LOCKING SCREW, Ø2.7X50MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
33 00817906027679 P72 ST147 LOCKING SCREW, Ø2.7X47.5MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
34 00817906027662 P72 ST145 LOCKING SCREW, Ø2.7X45MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
35 00817906027655 P72 ST142 LOCKING SCREW, Ø2.7X42.5MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
36 00817906027648 P72 ST140 LOCKING SCREW, Ø2.7X40MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
37 00817906027631 P72 ST137 LOCKING SCREW, Ø2.7X37.5MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
38 00817906027624 P72 ST135 LOCKING SCREW, Ø2.7X35MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
39 00817906027617 P72 ST132 LOCKING SCREW, Ø2.7X32.5MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
40 00817906027600 P72 ST130 LOCKING SCREW, Ø2.7X30MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
41 00817906027594 P72 ST128 LOCKING SCREW, Ø2.7X28MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
42 00817906027587 P72 ST126 LOCKING SCREW, Ø2.7X26MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
43 00817906027570 P72 ST124 LOCKING SCREW, Ø2.7X24MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
44 00817906027563 P72 ST122 LOCKING SCREW, Ø2.7X22MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
45 00817906027556 P72 ST120 LOCKING SCREW, Ø2.7X20MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
46 00817906027549 P72 ST118 LOCKING SCREW, Ø2.7X18MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
47 00817906027532 P72 ST116 LOCKING SCREW, Ø2.7X16MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
48 00817906027525 P72 ST114 LOCKING SCREW, Ø2.7X14MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
49 00817906027518 P72 ST112 LOCKING SCREW, Ø2.7X12MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
50 00817906027501 P72 ST110 LOCKING SCREW, Ø2.7X10MM HWC Screw, Fixation, Bone 2 CoLink™ Afx
Other products with the same Product Code "HRS"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 M621OW30LBS26MM0 GM-500-26 OW3.0LBS-26MM osteo-WEDGE 3.0mm x 26mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 26mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 26mm Locking Bone Screw GRAMEDICA
2 M621OW30LBS24MM0 GM-500-24 OW3.0LBS-24MM osteo-WEDGE 3.0mm x 24mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 24mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 24mm Locking Bone Screw GRAMEDICA
3 M621OW30LBS22MM0 GM-500-22 OW3.0LBS-22MM osteo-WEDGE 3.0mm x 22mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 22mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 22mm Locking Bone Screw GRAMEDICA
4 M621OW30LBS20MM0 GM-500-20 OW3.0LBS-20MM osteo-WEDGE 3.0mm x 20mm Locking Bone Screw. For use with the osteo-WEDGE Openi osteo-WEDGE 3.0mm x 20mm Locking Bone Screw. For use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 20mm Locking Bone Screw GRAMEDICA
5 M621OW30LBS18MM0 GM-500-18 OW3.0LBS-18MM osteo-WEDGE 3.0mm x 18mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 18mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 18mm Locking Bone Screw GRAMEDICA
6 M621OW30LBS16MM0 GM-500-16 OW3.0LBS-16MM osteo-WEDGE 3.0mm x 16mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 16mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 16mm Locking Bone Screw GRAMEDICA
7 M621OW30LBS14MM0 GM-500-14 OW3.0LBS-14MM osteo-WEDGE 3.0mm x 14mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 14mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 14mm Locking Bone Screw GRAMEDICA
8 M621OW30LBS12MM0 GM-500-12 OW3.0LBS-12MM osteo-WEDGE 3.0mm x 12mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 12mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 12mm Locking Bone Screw GRAMEDICA
9 M621OW30LBS10MM0 GM-500-10 OW3.0LBS-10MM osteo-WEDGE 3.0mm x 10mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 10mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 10mm Locking Bone Screw GRAMEDICA
10 M621OW30LBS08MM0 GM-500-08 OW3.0LBS-08MM osteo-WEDGE 3.0mm x 08mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 3.0mm x 08mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 3.0mm x 08mm Locking Bone Screw GRAMEDICA
11 M621OW25LBS22MM0 GM-200-22 OW2.5LBS-22MM osteo-WEDGE 2.5mm x 22mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 22mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 22mm Locking Bone Screw GRAMEDICA
12 M621OW25LBS18MM0 GM-200-18 OW2.5LBS-18MM osteo-WEDGE 2.5mm x 18mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 18mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 18mm Locking Bone Screw GRAMEDICA
13 M621OW25LBS16MM0 GM-200-16 OW2.5LBS-16MM osteo-WEDGE 2.5mm x 16mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 16mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 16mm Locking Bone Screw GRAMEDICA
14 M621OW25LBS14MM0 GM-200-14 OW2.5LBS-14MM osteo-WEDGE 2.5mm x 14mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 14mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 14mm Locking Bone Screw GRAMEDICA
15 M621OW25LBS12MM0 GM-200-12 OW2.5LBS-12MM osteo-WEDGE 2.5mm x 12mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 12mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 12mm Locking Bone Screw GRAMEDICA
16 M621OW25LBS10MM0 GM-200-10 OW2.5LBS-10MM osteo-WEDGE 2.5mm x 10mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 10mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 10mm Locking Bone Screw GRAMEDICA
17 M621OW25LBS08MM0 GM-200-08 OW2.5LBS-08MM osteo-WEDGE 2.5mm x 08mm Locking Bone Screw. Non-sterile single use implant for osteo-WEDGE 2.5mm x 08mm Locking Bone Screw. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE 2.5mm x 08mm Locking Bone Screw GRAMEDICA
18 M621OW24TT12MM0 GM-100-12 OW2.4TT-12MM osteo-WEDGE Temporary Tack, 2.4mm x 12mm. Non-sterile single use (disposable) a osteo-WEDGE Temporary Tack, 2.4mm x 12mm. Non-sterile single use (disposable) accessory for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Temporary Tack 2.4mm x 12mm GRAMEDICA
19 M621GM504300 GM-504-30 GM-504-30 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 30 Degree Angulated Bone Plate Implant, Large GRAMEDICA
20 M621GM504270 GM-504-27 GM-504-27 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 27 Degree Angulated Bone Plate Implant, Large GRAMEDICA
21 M621GM504240 GM-504-24 GM-504-24 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 24 Degree Angulated Bone Plate Implant, Large GRAMEDICA
22 M621GM504210 GM-504-21 GM-504-21 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 21 Degree Angulated Bone Plate Implant, Large GRAMEDICA
23 M621GM504180 GM-504-18 GM-504-18 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 18 Degree Angulated Bone Plate Implant, Large GRAMEDICA
24 M621GM504150 GM-504-15 GM-504-15 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 15 Degree Angulated Bone Plate Implant, Large GRAMEDICA
25 M621GM504120 GM-504-12 GM-504-12 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 12 Degree Angulated Bone Plate Implant, Large GRAMEDICA
26 M621GM504090 GM-504-09 GM-504-09 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 9 Degree Angulated Bone Plate Implant, Large GRAMEDICA
27 M621GM504060 GM-504-06 GM-504-06 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 6 Degree Angulated Bone Plate Implant, Large GRAMEDICA
28 M621GM504030 GM-504-03 GM-504-03 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 3 Degree Angulated Bone Plate Implant, Large GRAMEDICA
29 M621GM503300 GM-503-30 GM-503-30 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 30 Degree Angulated Bone Plate Implant, Small GRAMEDICA
30 M621GM503270 GM-503-27 GM-503-27 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 27 Degree Angulated Bone Plate Implant, Small GRAMEDICA
31 M621GM503240 GM-503-24 GM-503-24 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 24 Degree Angulated Bone Plate Implant, Small GRAMEDICA
32 M621GM503210 GM-503-21 GM-503-21 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 21 Degree Angulated Bone Plate Implant, Small GRAMEDICA
33 M621GM503180 GM-503-18 GM-503-18 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 18 Degree Angulated Bone Plate Implant-Small GRAMEDICA
34 M621GM503150 GM-503-15 GM-503-15 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 15 Degree Angulated Bone Plate Implant, Small GRAMEDICA
35 M621GM503120 GM-503-12 GM-503-12 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 12 Degree Angulated Bone Plate Implant, Small GRAMEDICA
36 M621GM503090 GM-503-09 GM-503-09 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 9 Degree Angulated Bone Plate Implant, Small GRAMEDICA
37 M621GM503060 GM-503-06 GM-503-06 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 6 Degree Angulated Bone Plate Implant, Small GRAMEDICA
38 M621GM503030 GM-503-03 GM-503-03 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 3 Degree Angulated Bone Plate Implant, Small GRAMEDICA
39 M621GM503000 GM-503-00 GM-503-00 The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and tr The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 0 Degree, Flat Bone Plate Implant, Small GRAMEDICA
40 M621GM501100 GM-501-10 GM-501-10 osteo-WEDGE Bone Plate 10mm. Non-sterile single use implant for use with the ost osteo-WEDGE Bone Plate 10mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 10mm GRAMEDICA
41 M621GM501080 GM-501-08 GM-501-08 osteo-WEDGE Bone Plate 08mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 08mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 08mm GRAMEDICA
42 M621GM501060 GM-501-06 GM-501-06 osteo-WEDGE Bone Plate 06mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 06mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 06mm GRAMEDICA
43 M621GM501040 GM-501-04 GM-501-04 osteo-WEDGE Bone Plate 04mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 04mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 04mm GRAMEDICA
44 M621GM501020 GM-501-02 GM-501-02 osteo-WEDGE Bone Plate 02mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 02mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 02mm GRAMEDICA
45 M621GM501000 GM-501-00 GM-501-00 osteo-WEDGE Bone Plate 00mm. Non-sterile single use implant for use with the os osteo-WEDGE Bone Plate 00mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Bone Plate 00mm GRAMEDICA
46 M621GM160040 GM-160-04 GM-160-04 osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE O osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 Drill Guide GRAMEDICA
47 M621GM160030 GM-160-03 GM-160-03 osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE O osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE2 Drill Guide GRAMEDICA
48 M621GM160010 GM-160-01 GM-160-01 osteo-WEDGE Drill Guide, a reusable instrument, for use with the osteo-WEDGE Op osteo-WEDGE Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Drill Guide GRAMEDICA
49 M621GM150040 GM-150-04 GM-150-04 osteo-WEDGE Screw Retainer Sleeve, a reusable instrument, for use with the oste osteo-WEDGE Screw Retainer Sleeve, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Screw Retainer Sleeve GRAMEDICA
50 M621GM150030 GM-150-03 GM-150-03 osteo-WEDGE Driver, a reusable instrument, for use with the osteo-WEDGE Opening osteo-WEDGE Driver, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations. osteo-WEDGE Driver GRAMEDICA