DOPPLER AND PLETHYSMOGRAPH SYSTEM - The line-powered instrument contains a direc
DOPPLER AND PLETHYSMOGRAPH SYSTEM - The line-powered instrument contains a direction-sensing continuous wave Doppler, a photo plethysmograph, and a pneumo plethysmograph. Several types of diagnostic tests can be performed allowing the user to choose the most appropriate one for the particular study of interest. A built-in two speed chart recorder can record the waveform from the selected instrument mode. A digital output is included so waveforms can also be captured in computer software.
PHOTOTRANSDUCER; 4 PIN CONNECTOR EC6 - A plethysmograph sensor that attaches to
PHOTOTRANSDUCER; 4 PIN CONNECTOR EC6 - A plethysmograph sensor that attaches to an electronic plethysmograph instrument, used to measure volume changes due to blood flow changes in a limb or digit. The plethysmograph instrument measures the signal to determine changes in blood volume in the tissue under the sensor.
PHOTOTRANSDUCER; 5 PIN CONNECTOR - A plethysmograph sensor that attaches to an e
PHOTOTRANSDUCER; 5 PIN CONNECTOR - A plethysmograph sensor that attaches to an electronic plethysmograph instrument, used to measure volume changes due to blood flow changes in a limb or digit. The plethysmograph instrument measures the signal to determine changes in blood volume in the tissue under the sensor.
PHOTOTRANSDUCER; 4 PIN CONNECTOR - A plethysmograph sensor that attaches to an e
PHOTOTRANSDUCER; 4 PIN CONNECTOR - A plethysmograph sensor that attaches to an electronic plethysmograph instrument, used to measure volume changes due to blood flow changes in a limb or digit. The plethysmograph instrument measures the signal to determine changes in blood volume in the tissue under the sensor.
ARTERIAL INFLOW SYSTEM - Measures arterial inflow in the extremities using the p
ARTERIAL INFLOW SYSTEM - Measures arterial inflow in the extremities using the principle of venous occlusion plethysmography. The system uses software to combine strain gauge plethysmography, rapid cuff inflation, and optional R-wave heart beat detection and invasive blood pressure to measure the arterial inflow rate in one or two limbs simultaneously.
JOM
Plethysmograph, Photoelectric, Pneumatic Or Hydraulic
RAPID CUFF DEFLATOR - BAYONET VERSION - A single pneumatic valve accessory for i
RAPID CUFF DEFLATOR - BAYONET VERSION - A single pneumatic valve accessory for interconnecting a cuff inflator to one or two blood pressure cuffs. The cuffs can be rapidly deflated completely with the valve of the pneumatic valve accessory, separately from the cuff inflator.
DOPPLER AND PLETHYSMOGRAPH SYSTEM - The line-powered instrument contains a direc
DOPPLER AND PLETHYSMOGRAPH SYSTEM - The line-powered instrument contains a direction-sensing continuous wave Doppler, a photo plethysmograph, and a pneumo plethysmograph. Several types of diagnostic tests can be performed allowing the user to choose the most appropriate one for the particular study of interest. A built-in two speed chart recorder can record the waveform from the selected instrument mode. A digital output is included so waveforms can also be captured in computer software.
Calculating Cuff Inflator-Wireless Version - A portable cuff inflator with an el
Calculating Cuff Inflator-Wireless Version - A portable cuff inflator with an electronic memory and calculator used to measure segmental limb systolic pressures and calculate pressure indices. Inflation and deflation are controlled by the clinician. Measured pressure readings can be stored in memory registers of the device, or sent directly to a computer. The instrument is powered by rechargeable batteries.
Calculating Cuff Inflator-Data Link Version - A portable cuff inflator with an e
Calculating Cuff Inflator-Data Link Version - A portable cuff inflator with an electronic memory and calculator used to measure segmental limb systolic pressures and calculate pressure indices. Inflation and deflation are controlled by the clinician. Measured pressure readings can be stored in memory registers of the device, or sent directly to a computer. The instrument is powered by rechargeable batteries.
SEGMENTAL CUFF SELECTOR - A pneumatic valve system for interconnecting a cuff in
SEGMENTAL CUFF SELECTOR - A pneumatic valve system for interconnecting a cuff inflator to one or multiple blood pressure cuffs. The cuffs can be deflated completely with the valve(s) of the pneumatic valve system, separately from the cuff inflator.
ARTERIAL INFLOW SYSTEM - Measures arterial inflow in the extremities using the p
ARTERIAL INFLOW SYSTEM - Measures arterial inflow in the extremities using the principle of venous occlusion plethysmography. The system uses software to combine strain gauge plethysmography, rapid cuff inflation, and optional R-wave heart beat detection and invasive blood pressure to measure the arterial inflow rate in one or two limbs simultaneously.
ECG TRIGGER - A battery powered instrument used to acquire an ECG signal from a
ECG TRIGGER - A battery powered instrument used to acquire an ECG signal from a subject. The instrument filters and amplifies the patient's ECG R-wave, then sends the signal to a parent device via and optically isolated interface cable. The output signal can be used by the parent device to synchronize another event with the subject’s R-Wave. The waveform is NOT used for analysis or diagnosis due to the ECG signal filtering.
STRAIN GAUGE AND PHOTO PLETHYSMOGRAPH; 115V OR 220V - A mains powered plethysmog
STRAIN GAUGE AND PHOTO PLETHYSMOGRAPH; 115V OR 220V - A mains powered plethysmograph instrument. The user can select between strain gauge and photo plethysmography modes. An analog meter on the front of the instrument indicates the signal level and is calibrated in % Volume Change for strain gauge applications. The plethysmograph signal is also available via analog and digital outputs, to a separate recording device.
STRAIN GAUGE AND PHOTO PLETHYSMOGRAPH; 100V - A mains powered plethysmograph ins
STRAIN GAUGE AND PHOTO PLETHYSMOGRAPH; 100V - A mains powered plethysmograph instrument. The user can select between strain gauge and photo plethysmography modes. An analog meter on the front of the instrument indicates the signal level and is calibrated in % Volume Change for strain gauge applications. The plethysmograph signal is also available via analog and digital outputs, to a separate recording device.
ARTERIAL INFLOW SYSTEM - Measures arterial inflow in the extremities using the p
ARTERIAL INFLOW SYSTEM - Measures arterial inflow in the extremities using the principle of venous occlusion plethysmography. The system uses software to combine strain gauge plethysmography, rapid cuff inflation, and optional R-wave heart beat detection and invasive blood pressure to measure the arterial inflow rate in one or two limbs simultaneously.
The TBL-ABI is indicated for use on adult subjects at risk of having or developi
The TBL-ABI is indicated for use on adult subjects at risk of having or developing peripheral arterial disease (PAD). TBL-ABI is intended for the rapid measurement of ankle-brachial pressure index (ABPI), or ankle-brachial index (ABI), and pulse volume recording (PVR) / volume plethysmography in adults. It is suitable for use in wound care assessment, for assessing symptomatic PAD, and as a screening device for PAD. It may also be used on patients with venous or arterial ulcers prior to the application of compression therapy. TBL-ABI can be used on patients with unilateral lower limb amputation.
The MESI mTABLET ABI is an automated wireless ankle-brachial index measuring sys
The MESI mTABLET ABI is an automated wireless ankle-brachial index measuring system for screening patients for Peripheral Arterial Disease (PAD/LEAD). The system is intended to perform, viewing and storing ankle-brachial index (ABI) measurement of adult patients –patients in the PAD risk group. It is a wireless system which is comprised of a wireless medical tablet system, four tubeless blood pressure cuff modules and a 4-port charging station module.
The MESI ABPI MD is an automated wireless ankle-brachial index measuring devic
The MESI ABPI MD is an automated wireless ankle-brachial index measuring device for screening patients for Peripheral Arterial Disease (PAD/LEAD). The device is intended to perform, view and store ankle-brachial index (ABI) measurements of adult patients –patients in the PAD risk group.
The device is intended to be used for monitoring and recording of, and to genera
The device is intended to be used for monitoring and recording of, and to generate alarms for, multiple physiological parameters of adults, pediatrics, and neonates