DOPPLER AND PLETHYSMOGRAPH SYSTEM - The line-powered instrument contains a direc
DOPPLER AND PLETHYSMOGRAPH SYSTEM - The line-powered instrument contains a direction-sensing continuous wave Doppler, a photo plethysmograph, and a pneumo plethysmograph. Several types of diagnostic tests can be performed allowing the user to choose the most appropriate one for the particular study of interest. A built-in two speed chart recorder can record the waveform from the selected instrument mode. A digital output is included so waveforms can also be captured in computer software.
PHOTOTRANSDUCER; 4 PIN CONNECTOR EC6 - A plethysmograph sensor that attaches to
PHOTOTRANSDUCER; 4 PIN CONNECTOR EC6 - A plethysmograph sensor that attaches to an electronic plethysmograph instrument, used to measure volume changes due to blood flow changes in a limb or digit. The plethysmograph instrument measures the signal to determine changes in blood volume in the tissue under the sensor.
PHOTOTRANSDUCER; 5 PIN CONNECTOR - A plethysmograph sensor that attaches to an e
PHOTOTRANSDUCER; 5 PIN CONNECTOR - A plethysmograph sensor that attaches to an electronic plethysmograph instrument, used to measure volume changes due to blood flow changes in a limb or digit. The plethysmograph instrument measures the signal to determine changes in blood volume in the tissue under the sensor.
PHOTOTRANSDUCER; 4 PIN CONNECTOR - A plethysmograph sensor that attaches to an e
PHOTOTRANSDUCER; 4 PIN CONNECTOR - A plethysmograph sensor that attaches to an electronic plethysmograph instrument, used to measure volume changes due to blood flow changes in a limb or digit. The plethysmograph instrument measures the signal to determine changes in blood volume in the tissue under the sensor.
ARTERIAL INFLOW SYSTEM - Measures arterial inflow in the extremities using the p
ARTERIAL INFLOW SYSTEM - Measures arterial inflow in the extremities using the principle of venous occlusion plethysmography. The system uses software to combine strain gauge plethysmography, rapid cuff inflation, and optional R-wave heart beat detection and invasive blood pressure to measure the arterial inflow rate in one or two limbs simultaneously.
JOM
Plethysmograph, Photoelectric, Pneumatic Or Hydraulic
RAPID CUFF DEFLATOR - BAYONET VERSION - A single pneumatic valve accessory for i
RAPID CUFF DEFLATOR - BAYONET VERSION - A single pneumatic valve accessory for interconnecting a cuff inflator to one or two blood pressure cuffs. The cuffs can be rapidly deflated completely with the valve of the pneumatic valve accessory, separately from the cuff inflator.
DOPPLER AND PLETHYSMOGRAPH SYSTEM - The line-powered instrument contains a direc
DOPPLER AND PLETHYSMOGRAPH SYSTEM - The line-powered instrument contains a direction-sensing continuous wave Doppler, a photo plethysmograph, and a pneumo plethysmograph. Several types of diagnostic tests can be performed allowing the user to choose the most appropriate one for the particular study of interest. A built-in two speed chart recorder can record the waveform from the selected instrument mode. A digital output is included so waveforms can also be captured in computer software.
Calculating Cuff Inflator-Wireless Version - A portable cuff inflator with an el
Calculating Cuff Inflator-Wireless Version - A portable cuff inflator with an electronic memory and calculator used to measure segmental limb systolic pressures and calculate pressure indices. Inflation and deflation are controlled by the clinician. Measured pressure readings can be stored in memory registers of the device, or sent directly to a computer. The instrument is powered by rechargeable batteries.
Calculating Cuff Inflator-Data Link Version - A portable cuff inflator with an e
Calculating Cuff Inflator-Data Link Version - A portable cuff inflator with an electronic memory and calculator used to measure segmental limb systolic pressures and calculate pressure indices. Inflation and deflation are controlled by the clinician. Measured pressure readings can be stored in memory registers of the device, or sent directly to a computer. The instrument is powered by rechargeable batteries.
SEGMENTAL CUFF SELECTOR - A pneumatic valve system for interconnecting a cuff in
SEGMENTAL CUFF SELECTOR - A pneumatic valve system for interconnecting a cuff inflator to one or multiple blood pressure cuffs. The cuffs can be deflated completely with the valve(s) of the pneumatic valve system, separately from the cuff inflator.
The product automatically measures human begins Systolic, Diastolic blood pressu
The product automatically measures human begins Systolic, Diastolic blood pressure and pulse rate by oscillometric method. The measurement results are displayed on the LCD. Measurement position is at human being's wrist. The intended use of this over-the-counter device is for adults with wrist circumference ranging from 125 mm to 210 mm (Approx.4.9 ~ 8.3 inches) and for home use. When the device detects the appearance of irregular heartbeats such as atrial or ventricular premature beats during measurement, an indicated symbol will appear with measuring readings. This device is designed only for adults.
BPM19 Series Blood Pressure Monitor applies the Oscillometric method to measure
BPM19 Series Blood Pressure Monitor applies the Oscillometric method to measure human systolic / diastolic blood pressure and heart rate. All values are shown on the LCD monitor. This device is designed only for adults.
The device is a arm type blood pressure monitor intended for automatically measu
The device is a arm type blood pressure monitor intended for automatically measures systolic and diastolic blood pressure and pulse rate by the oscillometric method. The measurement position is at the arm.The cuff circumference is limited to 220 mm - 420 mm (approx.:9 - 17 inches).The device is intended for home use. When the device detects irregular heart beats during measurement, an irregular heartbeat symbol will appear along with the measured readings
The device is a wrist type blood pressure monitor intended for automatically mea
The device is a wrist type blood pressure monitor intended for automatically measures systolic and diastolic blood pressure and pulse rate by the oscillometric method. The measurement position is at the wrist. The device is intended to be used by adults with a wrist circumference ranging from 125mm to 210mm (approx. 4.9 to 8.3 inches). The device is intended for home use. When the device detects irregular heartbeats during measurement, an irregular heartbeat symbol will appear along with the measured readings.
Bluetooth Blood Pressure MonitorUpper-arm blood pressure monitor intended to mea
Bluetooth Blood Pressure MonitorUpper-arm blood pressure monitor intended to measure and monitor the arterial blood pressure values and the heart rates of adults with an arm circumference of 8.7 in to16.5 in (22cm to 42cm), in a non-invasive way.
Bluetooth Blood Pressure Monitor (SBM69)Upper-arm blood pressure monitor intende
Bluetooth Blood Pressure Monitor (SBM69)Upper-arm blood pressure monitor intended to measure and monitor the arterial blood pressure values and the heart rates of adults with an arm circumference of 8.7 in to16.5 in (22cm to 42cm), in a non-invasive way.