Two levels of controls for the following assays: TPSA, FPSAFPSA is not available
Two levels of controls for the following assays: TPSA, FPSAFPSA is not available in the US.
JJX
Single (Specified) Analyte Controls (Assayed And Unassayed)
Used to dilute the sample if the test result reads outside the assay range. Max
Used to dilute the sample if the test result reads outside the assay range. Maximum two serial dilutions per sample.
30 Test SHBG Immunoassay Complete Kit w/Calibrator and Controls
JJX,JIT,CDZ
Single (Specified) Analyte Controls (Assayed And Unassayed),Calibrator, Secondar
Single (Specified) Analyte Controls (Assayed And Unassayed),Calibrator, Secondary,Radioimmunoassay, Testosterones And Dihydrotestosterone
60 Test SHBG Immunoassay Complete Kit w/Calibrator and Control
JJX,JIT,CDZ
Single (Specified) Analyte Controls (Assayed And Unassayed),Calibrator, Secondar
Single (Specified) Analyte Controls (Assayed And Unassayed),Calibrator, Secondary,Radioimmunoassay, Testosterones And Dihydrotestosterone
1. QUANTA Flash Calprotectin Calibrator 1: Two (2) barcode labeled tubes contain
1. QUANTA Flash Calprotectin Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain recombinant calprotectin with stabilizers and preservatives. 2. QUANTA Flash Calprotectin Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain recombinant calprotectin with stabilizers and preservatives. 3. QUANTA Flash Calprotectin Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain recombinant calprotectin with stabilizers and preservatives.
1. QUANTA Flash RF IgM Calibrator 1: Two (2) barcode labeled tubes containing 0.
1. QUANTA Flash RF IgM Calibrator 1: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgM in stabilizers and preservatives.2. QUANTA Flash RF IgM Calibrator 2: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgM in stabilizers and preservatives.
1. QUANTA Flash RF IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.
1. QUANTA Flash RF IgA Calibrator 1: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgA in stabilizers and preservatives.2. QUANTA Flash RF IgA Calibrator 2: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to RF IgA in stabilizers and preservatives.
1. QUANTA Flash HMGCR Calibrator 1: Two (2) barcode labeled tubes containing 0.3
1. QUANTA Flash HMGCR Calibrator 1: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to HMGCR in stabilizers and preservatives.2. QUANTA Flash HMGCR Calibrator 2: Two (2) barcode labeled tubes containing 0.3mL prediluted, ready to use reagent. Calibrators contain human antibodies to HMGCR in stabilizers and preservatives.
1. QUANTA Flash LKM-1 Calibrator 1: Two (2) barcode labeled tubes containing 0.3
1. QUANTA Flash LKM-1 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.2. QUANTA Flash LKM-1 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.3. QUANTA Flash LKM-1 Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to LKM-1 in stabilizers and preservatives.
1. QUANTA Flash M2 (MIT3) Calibrator 1: Two (2) barcode labeled tubes containing
1. QUANTA Flash M2 (MIT3) Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.2. QUANTA Flash M2 (MIT3) Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.3. QUANTA Flash M2 (MIT3) Calibrator 3: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to M2 (MIT3) in stabilizers and preservatives.
1. QUANTA Flash Scl-70 Calibrator 1: Two (2) barcode labeled tubes containing 0
1. QUANTA Flash Scl-70 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Scl-70 in stabilizers and preservatives. 2. QUANTA Flash Scl-70 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Scl-70 in stabilizers and preservatives.
1. QUANTA Flash CCP3 Calibrator 1: Two (2) barcode labeled tubes containing 0.7
1. QUANTA Flash CCP3 Calibrator 1: Two (2) barcode labeled tubes containing 0.7 mL prediluted, ready to use reagent. Calibrators contain human antibodies to CCP3 in stabilizers and preservatives. 2. QUANTA Flash CCP3 Calibrator 2: Two (2) barcode labeled tubes containing 0.7 mL prediluted, ready to use reagent. Calibrators contain human antibodies to CCP3 in stabilizers and preservatives.
1. QUANTA Flash dsDNA Calibrator 1: Two (2) barcode labeled tubes containing 0.7
1. QUANTA Flash dsDNA Calibrator 1: Two (2) barcode labeled tubes containing 0.7 mL prediluted, ready to use reagent. Calibrators contain human antibodies to dsDNA in stabilizers and preservatives. 2. QUANTA Flash dsDNA Calibrator 2: Two (2) barcode labeled tubes containing 0.7 mL prediluted, ready to use reagent. Calibrators contain human antibodies to dsDNA in stabilizers and preservatives.
1. QUANTA Flash Ro60 Calibrator 1: Two (2) barcode labeled tubes containing 0.3
1. QUANTA Flash Ro60 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro60 in stabilizers and preservatives. 2. QUANTA Flash Ro60 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro60 in stabilizers and preservatives.
1. QUANTA Flash Ro52 Calibrator 1: Two (2) barcode labeled tubes containing 0.3
1. QUANTA Flash Ro52 Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro52 in stabilizers and preservatives. 2. QUANTA Flash Ro52 Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Ro52 in stabilizers and preservatives.
1. QUANTA Flash SS-B Calibrator 1: Two (2) barcode labeled tubes containing 0.3
1. QUANTA Flash SS-B Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to SS-B in stabilizers and preservatives. 2. QUANTA Flash SS-B Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to SS-B in stabilizers and preservatives.
1. QUANTA Flash Sm Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL
1. QUANTA Flash Sm Calibrator 1: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Sm in stabilizers and preservatives. 2. QUANTA Flash Sm Calibrator 2: Two (2) barcode labeled tubes containing 0.3 mL prediluted, ready to use reagent. Calibrators contain human antibodies to Sm in stabilizers and preservatives.