Other products from "WENZEL SPINE, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00813210022300 800-0235 Polyaxial Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
2 00813210022294 800-0233 Post Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
3 00813210022096 800-1206 EMG Cannula LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
4 00813210022157 800-1221 3mm Cannulated Power Drill LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
5 00813210022133 800-1215 Ratcheting Driver Handle LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
6 00813210022126 800-1210 Cannula Inserter LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
7 00813210022119 800-1208 Single Bevel Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
8 00813210022102 800-1207 Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
9 00813210022089 800-1205 Standard Cannula LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
10 00813210022072 800-1204 Guide Wire Stiffener LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
11 00813210022065 800-1202 Cannulated Tap LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
12 00813210022041 800-1200 Guide Wire (single use, disposable) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
13 00813210022034 800-1213 Threaded Implant Holder Shaft - Solid MRW System, Facet Screw Spinal Device U primaLOK FF
14 00813210022027 800-1212 Threaded Implant Holder Shaft - Cannulated MRW System, Facet Screw Spinal Device U primaLOK FF
15 00813210022010 800-1211 Implant Driver MRW System, Facet Screw Spinal Device U primaLOK FF
16 00813210022003 800-1203 Removal Driver MRW System, Facet Screw Spinal Device U primaLOK FF
17 00813210021990 800-1145-00 primaLOK FF 45mm Implant Assembly, Sterile primaLOK FF 45mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
18 00813210021983 800-1140-00 primaLOK FF 40mm Implant Assembly, Sterile primaLOK FF 40mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
19 00813210021976 800-1135-00 primaLOK FF 35mm Implant Assembly, Sterile primaLOK FF 35mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
20 00813210021969 800-1130-00 primaLOK FF 30mm Implant Assembly, Sterile primaLOK FF 30mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
21 00813210021952 800-1125-00 primaLOK FF 25mm Implant Assembly, Sterile primaLOK FF 25mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
22 00813210021945 800-1501 Percutaneous Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
23 00813210021938 800-1500 Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
24 00813210020856 CIC2-10-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
25 00813210020849 CIC2-09-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
26 00813210020832 CIC2-08-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
27 00813210020825 CIC2-A750 VariLift-C Unlocking Rod LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
28 00813210020818 CIC2-A746 VariLift-C 10mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
29 00813210020801 CIC2-A745 VariLift-C 09mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
30 00813210020795 CIC2-A744 VariLift-C 08mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
31 00813210020788 CIC2-A743 Expander ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
32 00813210020771 CIC2-A742 Retainer ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
33 00813210020764 CIC2-A741 Inserter ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
34 00813210020719 CIC1-A743-C01 Expansion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
35 00813210020702 CIC1-A741-C01 Insertion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
36 00813210020269 CIC1-A749 Graft Ejector LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
37 00813210020252 CIC1-A747 Removal Screwdriver ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
38 00813210020245 CIC1-A745 Tap, 9.0mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
39 00813210020238 CIC1-A744 Tap, 7.5mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
40 00813210020221 CIC1-A743 Expansion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
41 00813210020214 CIC1-A742 Locking Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
42 00813210020207 CIC1-A741 Insertion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
43 00813210020061 CIC1-9.0-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
44 00813210020054 CIC1-7.5-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
45 00813210020047 CIC1-9.0-12-BP The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
46 00813210020030 CIC1-7.5-12-BP The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
47 00813210021341 CIC2-A001 VariLift-C Instrument Case LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
48 00813210022393 800-0306 Implant Sizer - 6mm LXH Orthopedic Manual Surgical Instrument 1 primaLOK-SP
49 00813210020696 CIE3-A128 Expander, 28mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
50 00813210020689 CIE3-A124 Expander, 24mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
Other products with the same Product Code "LXH"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00643169997417 EX0217068 DISTRACTOR EX0217068 10MM BULLET N/A MEDTRONIC SOFAMOR DANEK, INC.
2 00643169983694 EX0217088 HANDLE EX0217088 EGG TRI FLAT N/A MEDTRONIC SOFAMOR DANEK, INC.
3 00643169978300 EX0217012 COUNTER TORQUE EX0217012 BI DRNL 5.5/6.0 N/A MEDTRONIC SOFAMOR DANEK, INC.
4 00643169971080 EX1216009 CROSSBAR EX1216009 FLEX ARM FRAME N/A MEDTRONIC SOFAMOR DANEK, INC.
5 00643169971073 EX1216008 LEG EX1216008 FLEX ARM FRAME N/A MEDTRONIC SOFAMOR DANEK, INC.
6 00643169971066 EX1216007 WELDMENT EX1216007 FLEX ARM FRAME N/A MEDTRONIC SOFAMOR DANEK, INC.
7 00643169968608 EX0117064 DISTRACTOR EX0117064 RATCHETING 5.5/6.0 N/A MEDTRONIC SOFAMOR DANEK, INC.
8 00643169966543 EX0217001 ALIGNMENT TOOL EX0217001 LONG N/A MEDTRONIC SOFAMOR DANEK, INC.
9 00643169966482 EX1016104 DISTRACTOR EX1016104 5.5/6.0 TLIF/PLIF N/A MEDTRONIC SOFAMOR DANEK, INC.
10 00643169961944 EX0117006 FUNNEL EX0117006 30DEG CURVE BONE N/A MEDTRONIC SOFAMOR DANEK, INC.
11 00643169936843 EX1116025 SPREADER EX1116025 N/A MEDTRONIC SOFAMOR DANEK, INC.
12 00643169936119 X1116104 TAMPONADE X1116104 CANNULATED-5.5 X 40 N/A MEDTRONIC SOFAMOR DANEK, INC.
13 00643169936102 X1116103 TAMPONADE X1116103 CANNULATED-5.5 X 35 N/A MEDTRONIC SOFAMOR DANEK, INC.
14 00643169936096 X1116102 TAMPONADE X1116102 CANNULATED-5.5 X 30 N/A MEDTRONIC SOFAMOR DANEK, INC.
15 00643169936089 X1116101 TAMPONADE X1116101 CANNULATED-5.5 X 25 N/A MEDTRONIC SOFAMOR DANEK, INC.
16 00643169936072 X1116100 TAMPONADE X1116100 CANNULATED-5.0 X 40 n/a MEDTRONIC SOFAMOR DANEK, INC.
17 00643169936065 X1116099 TAMPONADE X1116099 CANNULATED-5.0 X 35 N/A MEDTRONIC SOFAMOR DANEK, INC.
18 00643169936058 X1116098 TAMPONADE X1116098 CANNULATED-5.0 X 30 N/A MEDTRONIC SOFAMOR DANEK, INC.
19 00643169936041 X1116097 TAMPONADE X1116097 CANNULATED-5.0 X 25 N/A MEDTRONIC SOFAMOR DANEK, INC.
20 00643169936034 X1116096 TAMPONADE X1116096 CANNULATED-4.5 X 40 n/a MEDTRONIC SOFAMOR DANEK, INC.
21 00643169936027 X1116095 TAMPONADE X1116095 CANNULATED-4.5 X 35 n/a MEDTRONIC SOFAMOR DANEK, INC.
22 00643169936010 X1116094 TAMPONADE X1116094 CANNULATED-4.5 X 30 n/a MEDTRONIC SOFAMOR DANEK, INC.
23 00643169936003 X1116093 TAMPONADE X1116093 CANNULATED-4.5 X 25 N/A MEDTRONIC SOFAMOR DANEK, INC.
24 00643169935990 X1116092 TAMPONADE X1116092 CANNULATED-4.0 X 40 N/A MEDTRONIC SOFAMOR DANEK, INC.
25 00643169935983 X1116091 TAMPONADE X1116091 CANNULATED-4.0 X 35 N/A MEDTRONIC SOFAMOR DANEK, INC.
26 00643169935976 X1116090 TAMPONADE X1116090 CANNULATED-4.0 X 30 n/a MEDTRONIC SOFAMOR DANEK, INC.
27 00643169935969 X1116089 TAMPONADE X1116089 CANNULATED-4.0 X 25 n/a MEDTRONIC SOFAMOR DANEK, INC.
28 00643169935952 X1116088 TAMPONADE X1116088 CANNULATED-3.75 X 40 N/A MEDTRONIC SOFAMOR DANEK, INC.
29 00643169935945 X1116087 TAMPONADE X1116087 CANNULATED-3.75 X 35 N/A MEDTRONIC SOFAMOR DANEK, INC.
30 00643169935938 X1116086 TAMPONADE X1116086 CANNULATED-3.75 X 30 N/A MEDTRONIC SOFAMOR DANEK, INC.
31 00643169935921 X1116085 TAMPONADE X1116085 CANNULATED-3.75 X 25 N/A MEDTRONIC SOFAMOR DANEK, INC.
32 00643169933415 9735571 ACCESSORY KIT 9735571 VISUALASE NEURO Visualase MEDTRONIC NAVIGATION, INC.
33 00643169931756 EX1016028 FUNNEL EX1016028 N/A MEDTRONIC SOFAMOR DANEK, INC.
34 00643169931749 EX1016027 PLUNGER EX1016027 N/A MEDTRONIC SOFAMOR DANEK, INC.
35 00643169931732 EX1016026 TUBE EX1016026 DELIVERY N/A MEDTRONIC SOFAMOR DANEK, INC.
36 00643169931725 EX1116024 GUIDE EX1116024 ANGLED AWL N/A MEDTRONIC SOFAMOR DANEK, INC.
37 00643169930223 X1116040 PUSHER X1116040 CURVED GRAFT N/A MEDTRONIC SOFAMOR DANEK, INC.
38 00643169930216 X1116039 FUNNEL X1116039 CURVED BONE N/A MEDTRONIC SOFAMOR DANEK, INC.
39 00643169925243 EX0816050 HANDLE EX0816050 6INCH QUICK CONNECT N/A MEDTRONIC SOFAMOR DANEK, INC.
40 00643169876897 EX1015029 REDUCER EX1015029 5.5 ROD N/A MEDTRONIC SOFAMOR DANEK, INC.
41 00643169875586 EX0816083 INTRODUCER EX0816083 3.2MM ROD N/A MEDTRONIC SOFAMOR DANEK, INC.
42 00643169873063 EX0916022 DISTRACTOR TIP EX0916022 BLUNT 10MM N/A MEDTRONIC SOFAMOR DANEK, INC.
43 00643169873056 EX0916021 DISTRACTOR TIP EX0916021 BLUNT 8MM N/A MEDTRONIC SOFAMOR DANEK, INC.
44 00643169873049 EX0916020 DISTRACTOR EX0916020 SHAFT N/A MEDTRONIC SOFAMOR DANEK, INC.
45 00643169865303 EX0816099 PROTECTOR EX0816099 TISSUE N/A MEDTRONIC SOFAMOR DANEK, INC.
46 00643169862180 EX0816045 DISTRACTOR EX0816045 9X12X45 N/A MEDTRONIC SOFAMOR DANEK, INC.
47 00643169862173 EX0816044 DISTRACTOR EX0816044 7X12X45 N/A MEDTRONIC SOFAMOR DANEK, INC.
48 00643169862166 EX0816043 DISTRACTOR EX0816043 5X12X45 N/A MEDTRONIC SOFAMOR DANEK, INC.
49 00643169859623 EX0816039 PROTECTOR EX0816039 ENDPLATE 18MM n/a MEDTRONIC SOFAMOR DANEK, INC.
50 00643169856578 EX0716028 TURNER EX0716028 4.75MM HEAD N/A MEDTRONIC SOFAMOR DANEK, INC.