Other products from "WENZEL SPINE, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00813210022300 800-0235 Polyaxial Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
2 00813210022294 800-0233 Post Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
3 00813210022096 800-1206 EMG Cannula LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
4 00813210022157 800-1221 3mm Cannulated Power Drill LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
5 00813210022133 800-1215 Ratcheting Driver Handle LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
6 00813210022126 800-1210 Cannula Inserter LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
7 00813210022119 800-1208 Single Bevel Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
8 00813210022102 800-1207 Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
9 00813210022089 800-1205 Standard Cannula LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
10 00813210022072 800-1204 Guide Wire Stiffener LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
11 00813210022065 800-1202 Cannulated Tap LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
12 00813210022041 800-1200 Guide Wire (single use, disposable) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
13 00813210022034 800-1213 Threaded Implant Holder Shaft - Solid MRW System, Facet Screw Spinal Device U primaLOK FF
14 00813210022027 800-1212 Threaded Implant Holder Shaft - Cannulated MRW System, Facet Screw Spinal Device U primaLOK FF
15 00813210022010 800-1211 Implant Driver MRW System, Facet Screw Spinal Device U primaLOK FF
16 00813210022003 800-1203 Removal Driver MRW System, Facet Screw Spinal Device U primaLOK FF
17 00813210021990 800-1145-00 primaLOK FF 45mm Implant Assembly, Sterile primaLOK FF 45mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
18 00813210021983 800-1140-00 primaLOK FF 40mm Implant Assembly, Sterile primaLOK FF 40mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
19 00813210021976 800-1135-00 primaLOK FF 35mm Implant Assembly, Sterile primaLOK FF 35mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
20 00813210021969 800-1130-00 primaLOK FF 30mm Implant Assembly, Sterile primaLOK FF 30mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
21 00813210021952 800-1125-00 primaLOK FF 25mm Implant Assembly, Sterile primaLOK FF 25mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
22 00813210021945 800-1501 Percutaneous Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
23 00813210021938 800-1500 Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
24 00813210020856 CIC2-10-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
25 00813210020849 CIC2-09-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
26 00813210020832 CIC2-08-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
27 00813210020825 CIC2-A750 VariLift-C Unlocking Rod LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
28 00813210020818 CIC2-A746 VariLift-C 10mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
29 00813210020801 CIC2-A745 VariLift-C 09mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
30 00813210020795 CIC2-A744 VariLift-C 08mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
31 00813210020788 CIC2-A743 Expander ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
32 00813210020771 CIC2-A742 Retainer ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
33 00813210020764 CIC2-A741 Inserter ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
34 00813210020719 CIC1-A743-C01 Expansion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
35 00813210020702 CIC1-A741-C01 Insertion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
36 00813210020269 CIC1-A749 Graft Ejector LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
37 00813210020252 CIC1-A747 Removal Screwdriver ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
38 00813210020245 CIC1-A745 Tap, 9.0mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
39 00813210020238 CIC1-A744 Tap, 7.5mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
40 00813210020221 CIC1-A743 Expansion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
41 00813210020214 CIC1-A742 Locking Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
42 00813210020207 CIC1-A741 Insertion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
43 00813210020061 CIC1-9.0-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
44 00813210020054 CIC1-7.5-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
45 00813210020047 CIC1-9.0-12-BP The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
46 00813210020030 CIC1-7.5-12-BP The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
47 00813210021341 CIC2-A001 VariLift-C Instrument Case LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
48 00813210022393 800-0306 Implant Sizer - 6mm LXH Orthopedic Manual Surgical Instrument 1 primaLOK-SP
49 00813210020696 CIE3-A128 Expander, 28mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
50 00813210020689 CIE3-A124 Expander, 24mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
Other products with the same Product Code "LXH"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 08719425465685 42-440-75 N/A Trephine for Revision ø 7.5 mm Screw Trephine for Revision ø 7.5 mm Screw BAAT MEDICAL PRODUCTS B.V.
2 08719425465678 42-440-65 N/A Trephine for Revision ø 6.5 mm Screw Trephine for Revision ø 6.5 mm Screw BAAT MEDICAL PRODUCTS B.V.
3 08719425465661 42-440-55 N/A Trephine for Revision ø 5.5 mm Screw Trephine for Revision ø 5.5 mm Screw BAAT MEDICAL PRODUCTS B.V.
4 08719425465654 42-440-45 N/A Trephine for Revision ø 4.5 mm Screw Trephine for Revision ø 4.5 mm Screw BAAT MEDICAL PRODUCTS B.V.
5 08698940973922 1040.03.011 1040.03.011 Flexible Screwdriver 3,5 mm Sayan SAYAN TIBBI ALETLER PAZARLAMA SANAYI VE TICARET LIMITED SIRKETI
6 08698940951623 1020.01.091 1020.01.091 SCREWDRIVER WITH HANDLE SW3,5mm BLACK Sayan SAYAN TIBBI ALETLER PAZARLAMA SANAYI VE TICARET LIMITED SIRKETI
7 08698940937160 1070.90.028 1070.90.028 TORQUE LIMITING T HANDLE 13NM BLUE Sayan SAYAN TIBBI ALETLER PAZARLAMA SANAYI VE TICARET LIMITED SIRKETI
8 08698940937009 1100.20.060 1100.20.060 HANDY TORQUE LIMITING T HANDLE 4NM 1/4" BLUE Sayan SAYAN TIBBI ALETLER PAZARLAMA SANAYI VE TICARET LIMITED SIRKETI
9 08698940936583 1040.71.004 1040.71.004 MIS-FLEX DUAL ACETABULAR REAMER HANDLE ZIMMER COUPLING Sayan SAYAN TIBBI ALETLER PAZARLAMA SANAYI VE TICARET LIMITED SIRKETI
10 08428898885615 904007 904007 SPEEDPASS DISPOSABLE BIOMET ORTHOPEDICS, LLC
11 08057968719231 9084.20.305 STANDARD RATCHET HANDLE BLACK HPF SRL
12 08057968719187 9095.10.115 SCREW CLAMP HPF SRL
13 08057968719026 9055.28.400 MULTI-USE HANDLE HPF SRL
14 08057968718975 01.10.10.2054 BLADES SUPPORT HANDLE (KNURLED ) HPF SRL
15 08057968718951 01.10.10.2081 EXTRACTOR HANDLE HPF SRL
16 08057968713147 H0050450169 ACETABULAR BLADE D50 mm LONG HPF SRL
17 08057968713130 H0050450159 ACETABULAR BLADE D50 mm SHORT HPF SRL
18 08057968716834 H0034000339 ACCESSORY "T" HANDLE HPF SRL
19 08057968716612 H5000060049 STANDARD RATCHET HANDLE BLUE HPF SRL
20 08057968716605 H5000060039 STANDARD RATCHET HANDLE BLACK HPF SRL
21 08057968716599 H5000060179 STANDARD HANDLE CANNULATED M6 BLUE HPF SRL
22 08057968716582 H5000060169 STANDARD HANDLE CANNULATED M6 BLACK HPF SRL
23 08057968716575 H5000060109 STANDARD HANDLE M6 BLUE HPF SRL
24 08057968716568 H5000060099 STANDARD HANDLE M6 BLACK HPF SRL
25 08057968716551 H5000060019 STANDARD HANDLE M8 BLUE HPF SRL
26 08057968716544 H5000060009 STANDARD HANDLE M8 BLACK HPF SRL
27 08057968716537 H5000060079 "T" HANDLE 90 mm M8 BLUE HPF SRL
28 08057968716520 H5000060089 "T" HANDLE 90 mm M8 BLACK HPF SRL
29 08057968716513 H5000060059 "T" HANDLE 120 mm M8 BLUE HPF SRL
30 08057968716506 H5000060069 "T" HANDLE 120 mm M8 BLACK HPF SRL
31 08057968716490 H0050051515 TRIAL HEAD D38 mm HPF SRL
32 08057968716483 H0050051514 LIGHTENED TRIAL HEAD D58 mm HPF SRL
33 08057968716476 H0050051513 LIGHTENED TRIAL HEAD D56 mm HPF SRL
34 08057968716469 H0050051512 LIGHTENED TRIAL HEAD D54 mm HPF SRL
35 08057968716452 H0050051511 LIGHTENED TRIAL HEAD D52 mm HPF SRL
36 08057968716445 H0050051510 LIGHTENED TRIAL HEAD D50 mm HPF SRL
37 08057968716438 H0050051509 LIGHTENED TRIAL HEAD D48 mm HPF SRL
38 08057968716421 H0050051508 LIGHTENED TRIAL HEAD D46 mm HPF SRL
39 08057968716414 H0050051507 LIGHTENED TRIAL HEAD D44 mm HPF SRL
40 08057968716407 H0050051506 LIGHTENED TRIAL HEAD D42 mm HPF SRL
41 08057968716391 H0050051505 TRIAL HEAD D40 mm HPF SRL
42 08057968713123 H0050450149 ACETABULAR BLADE D48 mm LONG HPF SRL
43 08057968714441 H0120500199 "T" HANDLE 170 mm CONN. ZIMMER HPF SRL
44 08057968714328 H5000050003 STANDARD RATCHET HANDLE BLACK HPF SRL
45 08057968713871 H0050451329 SHORT ACETABULAR BLADE D66 mm LONG HPF SRL
46 08057968713864 H0050451319 SHORT ACETABULAR BLADE D66 mm SHORT HPF SRL
47 08057968713857 H0050300559 THIN OSTEOTOME BLADE 127x10 WITH SLOT HPF SRL
48 08057968713840 H0050300549 THIN OSTEOTOME BLADE 127x8 WITH SLOT HPF SRL
49 08057968713833 H0050300539 THIN OSTEOTOME BLADE 76x20 WITH SLOT HPF SRL
50 08057968713826 H0050300529 THIN OSTEOTOME BLADE 76x12 WITH SLOT HPF SRL