Other products from "WENZEL SPINE, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00813210022300 800-0235 Polyaxial Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
2 00813210022294 800-0233 Post Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
3 00813210022157 800-1221 3mm Cannulated Power Drill LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
4 00813210022133 800-1215 Ratcheting Driver Handle LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
5 00813210022126 800-1210 Cannula Inserter LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
6 00813210022119 800-1208 Single Bevel Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
7 00813210022102 800-1207 Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
8 00813210022089 800-1205 Standard Cannula LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
9 00813210022072 800-1204 Guide Wire Stiffener LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
10 00813210022065 800-1202 Cannulated Tap LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
11 00813210022041 800-1200 Guide Wire (single use, disposable) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
12 00813210022034 800-1213 Threaded Implant Holder Shaft - Solid MRW System, Facet Screw Spinal Device U primaLOK FF
13 00813210022027 800-1212 Threaded Implant Holder Shaft - Cannulated MRW System, Facet Screw Spinal Device U primaLOK FF
14 00813210022010 800-1211 Implant Driver MRW System, Facet Screw Spinal Device U primaLOK FF
15 00813210022003 800-1203 Removal Driver MRW System, Facet Screw Spinal Device U primaLOK FF
16 00813210021990 800-1145-00 primaLOK FF 45mm Implant Assembly, Sterile primaLOK FF 45mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
17 00813210021983 800-1140-00 primaLOK FF 40mm Implant Assembly, Sterile primaLOK FF 40mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
18 00813210021976 800-1135-00 primaLOK FF 35mm Implant Assembly, Sterile primaLOK FF 35mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
19 00813210021969 800-1130-00 primaLOK FF 30mm Implant Assembly, Sterile primaLOK FF 30mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
20 00813210021952 800-1125-00 primaLOK FF 25mm Implant Assembly, Sterile primaLOK FF 25mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
21 00813210021945 800-1501 Percutaneous Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
22 00813210021938 800-1500 Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
23 00813210020856 CIC2-10-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
24 00813210020849 CIC2-09-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
25 00813210020832 CIC2-08-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
26 00813210020825 CIC2-A750 VariLift-C Unlocking Rod LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
27 00813210020818 CIC2-A746 VariLift-C 10mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
28 00813210020801 CIC2-A745 VariLift-C 09mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
29 00813210020795 CIC2-A744 VariLift-C 08mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
30 00813210020788 CIC2-A743 Expander ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
31 00813210020771 CIC2-A742 Retainer ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
32 00813210020764 CIC2-A741 Inserter ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
33 00813210020719 CIC1-A743-C01 Expansion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
34 00813210020702 CIC1-A741-C01 Insertion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
35 00813210020269 CIC1-A749 Graft Ejector LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
36 00813210020252 CIC1-A747 Removal Screwdriver ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
37 00813210020245 CIC1-A745 Tap, 9.0mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
38 00813210020238 CIC1-A744 Tap, 7.5mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
39 00813210020221 CIC1-A743 Expansion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
40 00813210020214 CIC1-A742 Locking Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
41 00813210020207 CIC1-A741 Insertion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
42 00813210020061 CIC1-9.0-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
43 00813210020054 CIC1-7.5-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
44 00813210020047 CIC1-9.0-12-BP The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
45 00813210020030 CIC1-7.5-12-BP The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
46 00813210021341 CIC2-A001 VariLift-C Instrument Case LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
47 00813210022393 800-0306 Implant Sizer - 6mm LXH Orthopedic Manual Surgical Instrument 1 primaLOK-SP
48 00813210020696 CIE3-A128 Expander, 28mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
49 00813210020689 CIE3-A124 Expander, 24mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
50 00813210020672 CIE3-A026 MI Graft Impactor LXH Orthopedic Manual Surgical Instrument 1 VariLift-LX
Other products with the same Product Code "LXH"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 08855540272040 72203254 72203254 FLEXIBLE TAP BIOSURE 8MM BIOSURE SMITH & NEPHEW, INC.
2 08855540271982 72203253 72203253 FLEXIBLE TAP BIOSURE 7MM BIOSURE SMITH & NEPHEW, INC.
3 08855540271814 72203252 72203252 FLEXIBLE TAP BIOSURE 6MM BIOSURE SMITH & NEPHEW, INC.
4 08809695618895 GS136-0627 GS136-0627 Cervical Trial AnyPlus® GS MEDICAL CO., LTD.
5 08809695609695 US114-9028 US114-9028 Rod Reduction-External AnyPlus® GS MEDICAL CO., LTD.
6 08809695609671 US114-9013 US114-9013 Torque Stabilizer AnyPlus® GS MEDICAL CO., LTD.
7 08809695609657 US114-9006 US114-9006 Emg Sleeve AnyPlus® GS MEDICAL CO., LTD.
8 08809695609640 US114-9005 US114-9005 Dilator 3 AnyPlus® GS MEDICAL CO., LTD.
9 08809695609633 US114-9004 US114-9004 Dilator 2 AnyPlus® GS MEDICAL CO., LTD.
10 08809695609626 US114-9003 US114-9003 Dilator 1 AnyPlus® GS MEDICAL CO., LTD.
11 08809695609619 US114-9001 US114-9001 Tower AnyPlus® GS MEDICAL CO., LTD.
12 08809695609541 US114-9010 US114-9010 Wanding Blade AnyPlus® GS MEDICAL CO., LTD.
13 08809695609527 US114-9012 US114-9012 Rod Inserter AnyPlus® GS MEDICAL CO., LTD.
14 08809544170024 MIX-EX4D MEDINAUT-Ix IMEDICOM CO., LTD.
15 08809544170017 MIX-EX4B MEDINAUT-Ix IMEDICOM CO., LTD.
16 08809544170000 MIX-EX4T MEDINAUT-Ix IMEDICOM CO., LTD.
17 08809317177922 IX2000 SPINAUT-Ix IMEDICOM CO., LTD.
18 08809317177915 IX1000 SPINAUT-Ix IMEDICOM CO., LTD.
19 08809317171289 MIX-EX1T MEDINAUT-Ix IMEDICOM CO., LTD.
20 08809317171272 MIX-EX1D MEDINAUT-Ix IMEDICOM CO., LTD.
21 08809317171265 MIX-EX1B MEDINAUT-Ix IMEDICOM CO., LTD.
22 08809317171258 MIX-CA1 MEDINAUT-Ix IMEDICOM CO., LTD.
23 08809317171241 ICD-EX3T MEDINAUT-Ix IMEDICOM CO., LTD.
24 08809317171234 ICD-EX3D MEDINAUT-Ix IMEDICOM CO., LTD.
25 08809317171227 ICD-EX3B MEDINAUT-Ix IMEDICOM CO., LTD.
26 08809317171210 ICD-EX2T MEDINAUT-Ix IMEDICOM CO., LTD.
27 08809317171203 ICD-EX2D MEDINAUT-Ix IMEDICOM CO., LTD.
28 08809317171197 ICD-EX2B MEDINAUT-Ix IMEDICOM CO., LTD.
29 08809317171180 ICD-CA3 MEDINAUT-Ix IMEDICOM CO., LTD.
30 08809317171173 ICD-CA2 MEDINAUT-Ix IMEDICOM CO., LTD.
31 08809317171159 ICD-WP2 MEDINAUT-Ix IMEDICOM CO., LTD.
32 08809317171142 ICD-WP1 MEDINAUT-Ix IMEDICOM CO., LTD.
33 08809317171135 ICD-SP1 MEDINAUT-Ix IMEDICOM CO., LTD.
34 08809317171128 ICD-NP1 MEDINAUT-Ix IMEDICOM CO., LTD.
35 08809317171111 ICD-ND1 MEDINAUT-Ix IMEDICOM CO., LTD.
36 08809317171104 ICD-GW1 MEDINAUT-Ix IMEDICOM CO., LTD.
37 08809317171098 ICD-EX1 MEDINAUT-Ix IMEDICOM CO., LTD.
38 08809317171081 ICD-CP1 MEDINAUT-Ix IMEDICOM CO., LTD.
39 08809317171074 ICD-CF1 MEDINAUT-Ix IMEDICOM CO., LTD.
40 08809317171067 ICD-CA1 MEDINAUT-Ix IMEDICOM CO., LTD.
41 08809282815652 111-063 Surgical Instrument JEIL MEDICAL CORPORATION
42 08809265158622 111-010 Surgical Instrument JEIL MEDICAL CORPORATION
43 08809265158431 111-LD-010 Surgical Instrument JEIL MEDICAL CORPORATION
44 08809265158424 111-TD-010 Surgical Instrument JEIL MEDICAL CORPORATION
45 08809265158417 111-120 Surgical Instrument JEIL MEDICAL CORPORATION
46 08809237299186 GS134-0731 GS134-0731 ALIF Trial AnyPlus® GS MEDICAL CO., LTD.
47 08806395498031 GS142-1900 GS142-1900 Quick Connect Handle CASSIOPEIA ACP GS MEDICAL CO., LTD.
48 08806395497966 GS142-4200 GS142-4200 Simple Plate Holder CASSIOPEIA ACP GS MEDICAL CO., LTD.
49 08806395497935 GS142-0803 GS142-0803 Screw Extractor CASSIOPEIA ACP GS MEDICAL CO., LTD.
50 08806395490462 GS138-7001 GS138-7001 Connector Bolt AnyPlus® GS MEDICAL CO., LTD.