Other products from "WENZEL SPINE, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00813210022300 800-0235 Polyaxial Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
2 00813210022294 800-0233 Post Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
3 00813210022096 800-1206 EMG Cannula LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
4 00813210022157 800-1221 3mm Cannulated Power Drill LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
5 00813210022133 800-1215 Ratcheting Driver Handle LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
6 00813210022126 800-1210 Cannula Inserter LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
7 00813210022119 800-1208 Single Bevel Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
8 00813210022102 800-1207 Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
9 00813210022089 800-1205 Standard Cannula LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
10 00813210022072 800-1204 Guide Wire Stiffener LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
11 00813210022065 800-1202 Cannulated Tap LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
12 00813210022041 800-1200 Guide Wire (single use, disposable) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
13 00813210022034 800-1213 Threaded Implant Holder Shaft - Solid MRW System, Facet Screw Spinal Device U primaLOK FF
14 00813210022027 800-1212 Threaded Implant Holder Shaft - Cannulated MRW System, Facet Screw Spinal Device U primaLOK FF
15 00813210022010 800-1211 Implant Driver MRW System, Facet Screw Spinal Device U primaLOK FF
16 00813210022003 800-1203 Removal Driver MRW System, Facet Screw Spinal Device U primaLOK FF
17 00813210021990 800-1145-00 primaLOK FF 45mm Implant Assembly, Sterile primaLOK FF 45mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
18 00813210021983 800-1140-00 primaLOK FF 40mm Implant Assembly, Sterile primaLOK FF 40mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
19 00813210021976 800-1135-00 primaLOK FF 35mm Implant Assembly, Sterile primaLOK FF 35mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
20 00813210021969 800-1130-00 primaLOK FF 30mm Implant Assembly, Sterile primaLOK FF 30mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
21 00813210021952 800-1125-00 primaLOK FF 25mm Implant Assembly, Sterile primaLOK FF 25mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
22 00813210021945 800-1501 Percutaneous Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
23 00813210021938 800-1500 Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
24 00813210020856 CIC2-10-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
25 00813210020849 CIC2-09-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
26 00813210020832 CIC2-08-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
27 00813210020825 CIC2-A750 VariLift-C Unlocking Rod LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
28 00813210020818 CIC2-A746 VariLift-C 10mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
29 00813210020801 CIC2-A745 VariLift-C 09mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
30 00813210020795 CIC2-A744 VariLift-C 08mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
31 00813210020788 CIC2-A743 Expander ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
32 00813210020771 CIC2-A742 Retainer ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
33 00813210020764 CIC2-A741 Inserter ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
34 00813210020719 CIC1-A743-C01 Expansion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
35 00813210020702 CIC1-A741-C01 Insertion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
36 00813210020269 CIC1-A749 Graft Ejector LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
37 00813210020252 CIC1-A747 Removal Screwdriver ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
38 00813210020245 CIC1-A745 Tap, 9.0mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
39 00813210020238 CIC1-A744 Tap, 7.5mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
40 00813210020221 CIC1-A743 Expansion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
41 00813210020214 CIC1-A742 Locking Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
42 00813210020207 CIC1-A741 Insertion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
43 00813210020061 CIC1-9.0-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
44 00813210020054 CIC1-7.5-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
45 00813210020047 CIC1-9.0-12-BP The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
46 00813210020030 CIC1-7.5-12-BP The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
47 00813210021341 CIC2-A001 VariLift-C Instrument Case LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
48 00813210022393 800-0306 Implant Sizer - 6mm LXH Orthopedic Manual Surgical Instrument 1 primaLOK-SP
49 00813210020696 CIE3-A128 Expander, 28mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
50 00813210020689 CIE3-A124 Expander, 24mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
Other products with the same Product Code "MAX"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04260636678967 65-TC-INSERTER TiPlus-TC Inserter, Straight Fortilink SURGALIGN SPINE TECHNOLOGIES, INC.
2 04260636678936 65-C-INS-TIPLUS Fortilink-C TiPlus Inserter, Housing Fortilink SURGALIGN SPINE TECHNOLOGIES, INC.
3 04260614036581 PET91606 Trial, H: 16 mm, 18°, 30/6 EIT PLIF Trial EIT EMERGING IMPLANT TECHNOLOGIES GMBH
4 04260614034051 LUI71561 EIT LLIF, H 15mm, 16°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
5 04260614034044 LUI71461 EIT LLIF, H 14mm, 16°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
6 04260614034037 LUI71361 EIT LLIF, H 13mm, 16°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
7 04260614034020 LUI71261 EIT LLIF, H 12mm, 16°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
8 04260614034013 LUI71161 EIT LLIF, H 11mm, 16°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
9 04260614034006 LUI71061 EIT LLIF, H 10mm, 16°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
10 04260614033993 LUI71656 EIT LLIF, H 16mm, 16°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
11 04260614033986 LUI71556 EIT LLIF, H 15mm, 16°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
12 04260614033979 LUI71456 EIT LLIF, H 14mm, 16°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
13 04260614033962 LUI71356 EIT LLIF, H 13mm, 16°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
14 04260614033955 LUI71256 EIT LLIF, H 12mm, 16°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
15 04260614033948 LUI71156 EIT LLIF, H 11mm, 16°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
16 04260614033931 LUI71056 EIT LLIF, H 10mm, 16°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
17 04260614033924 LUI71651 EIT LLIF, H 16mm, 16°, 50/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
18 04260614033917 LUI71551 EIT LLIF, H 15mm, 16°, 50/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
19 04260614033900 LUI71451 EIT LLIF, H 14mm, 16°, 50/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
20 04260614033894 LUI71351 EIT LLIF, H 13mm, 16°, 50/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
21 04260614033887 LUI71251 EIT LLIF, H 12mm, 16°, 50/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
22 04260614033870 LUI71151 EIT LLIF, H 11mm, 16°, 50/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
23 04260614033863 LUI71051 EIT LLIF, H 10mm, 16°, 50/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
24 04260614033856 LUI71646 EIT LLIF, H 16mm, 16°, 45/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
25 04260614033849 LUI71546 EIT LLIF, H 15mm, 16°, 45/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
26 04260614033832 LUI71446 EIT LLIF, H 14mm, 16°, 45/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
27 04260614033825 LUI71346 EIT LLIF, H 13mm, 16°, 45/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
28 04260614033818 LUI71246 EIT LLIF, H 12mm, 16°, 45/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
29 04260614033801 LUI71146 EIT LLIF, H 11mm, 16°, 45/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
30 04260614033795 LUI71046 EIT LLIF, H 10mm, 16°, 45/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
31 04260614033788 LUI71641 EIT LLIF, H 16mm, 16°, 40/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
32 04260614033771 LUI71541 EIT LLIF, H 15mm, 16°, 40/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
33 04260614033764 LUI71441 EIT LLIF, H 14mm, 16°, 40/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
34 04260614033757 LUI71341 EIT LLIF, H 13mm, 16°, 40/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
35 04260614033740 LUI71241 EIT LLIF, H 12mm, 16°, 40/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
36 04260614033733 LUI71041 EIT LLIF, H 10mm, 16°, 40/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
37 04260614033726 LUI81561 EIT LLIF, H 15mm, 8°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
38 04260614033719 LUI81461 EIT LLIF, H 14mm, 8°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
39 04260614033702 LUI81361 EIT LLIF, H 13mm, 8°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
40 04260614033696 LUI81261 EIT LLIF, H 12mm, 8°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
41 04260614033689 LUI81161 EIT LLIF, H 11mm, 8°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
42 04260614033672 LUI81061 EIT LLIF, H 10mm, 8°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
43 04260614033665 LUI80961 EIT LLIF, H 9mm, 8°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
44 04260614033658 LUI80861 EIT LLIF, H 8mm, 8°, 60/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
45 04260614033641 LUI81656 EIT LLIF, H 16mm, 8°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
46 04260614033634 LUI81556 EIT LLIF, H 15mm, 8°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
47 04260614033627 LUI81456 EIT LLIF, H 14mm, 8°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
48 04260614033610 LUI81356 EIT LLIF, H 13mm, 8°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
49 04260614033603 LUI81256 EIT LLIF, H 12mm, 8°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH
50 04260614033597 LUI81156 EIT LLIF, H 11mm, 8°, 55/26 EIT LLIF cage EIT EMERGING IMPLANT TECHNOLOGIES GMBH