Other products from "WENZEL SPINE, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00813210022300 800-0235 Polyaxial Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
2 00813210022294 800-0233 Post Plate Inserter KWP Appliance, Fixation, Spinal Interlaminal 2 primaLOK SP
3 00813210022096 800-1206 EMG Cannula LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
4 00813210022157 800-1221 3mm Cannulated Power Drill LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
5 00813210022133 800-1215 Ratcheting Driver Handle LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
6 00813210022126 800-1210 Cannula Inserter LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
7 00813210022119 800-1208 Single Bevel Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
8 00813210022102 800-1207 Access Needle (sterile, single use) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
9 00813210022089 800-1205 Standard Cannula LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
10 00813210022072 800-1204 Guide Wire Stiffener LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
11 00813210022065 800-1202 Cannulated Tap LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
12 00813210022041 800-1200 Guide Wire (single use, disposable) LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
13 00813210022034 800-1213 Threaded Implant Holder Shaft - Solid MRW System, Facet Screw Spinal Device U primaLOK FF
14 00813210022027 800-1212 Threaded Implant Holder Shaft - Cannulated MRW System, Facet Screw Spinal Device U primaLOK FF
15 00813210022010 800-1211 Implant Driver MRW System, Facet Screw Spinal Device U primaLOK FF
16 00813210022003 800-1203 Removal Driver MRW System, Facet Screw Spinal Device U primaLOK FF
17 00813210021990 800-1145-00 primaLOK FF 45mm Implant Assembly, Sterile primaLOK FF 45mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
18 00813210021983 800-1140-00 primaLOK FF 40mm Implant Assembly, Sterile primaLOK FF 40mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
19 00813210021976 800-1135-00 primaLOK FF 35mm Implant Assembly, Sterile primaLOK FF 35mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
20 00813210021969 800-1130-00 primaLOK FF 30mm Implant Assembly, Sterile primaLOK FF 30mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
21 00813210021952 800-1125-00 primaLOK FF 25mm Implant Assembly, Sterile primaLOK FF 25mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle. MRW System, Facet Screw Spinal Device U primaLOK FF
22 00813210021945 800-1501 Percutaneous Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
23 00813210021938 800-1500 Instrument Case LXH Orthopedic Manual Surgical Instrument 1 primaLOK FF
24 00813210020856 CIC2-10-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
25 00813210020849 CIC2-09-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
26 00813210020832 CIC2-08-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
27 00813210020825 CIC2-A750 VariLift-C Unlocking Rod LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
28 00813210020818 CIC2-A746 VariLift-C 10mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
29 00813210020801 CIC2-A745 VariLift-C 09mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
30 00813210020795 CIC2-A744 VariLift-C 08mm Trial LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
31 00813210020788 CIC2-A743 Expander ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
32 00813210020771 CIC2-A742 Retainer ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
33 00813210020764 CIC2-A741 Inserter ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
34 00813210020719 CIC1-A743-C01 Expansion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
35 00813210020702 CIC1-A741-C01 Insertion Wrench, T-Handle ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
36 00813210020269 CIC1-A749 Graft Ejector LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
37 00813210020252 CIC1-A747 Removal Screwdriver ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
38 00813210020245 CIC1-A745 Tap, 9.0mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
39 00813210020238 CIC1-A744 Tap, 7.5mm LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
40 00813210020221 CIC1-A743 Expansion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
41 00813210020214 CIC1-A742 Locking Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
42 00813210020207 CIC1-A741 Insertion Wrench ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
43 00813210020061 CIC1-9.0-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
44 00813210020054 CIC1-7.5-12-00 The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
45 00813210020047 CIC1-9.0-12-BP The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of The Wenzel Spine VariLift-C Cervical Interbody Fusion Device System consists of a self-tapping, expandable device with an interior expansion plate, and is grooved and fluted with large graft windows positioned between each of its four quadrants that provide bony contact with the endplates. VariLift-C may be used with or without supplemental fixation. VariLift-C is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have at least six weeks of non-operative treatment prior to treatment with VariLift-C. These DDD patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level. The VariLift-C is used to facilitate intervertebral body fusion in the cervical spine and is placed in a unilateral or a bilateral fashion via an anterior approach at the C3 to C7 disc levels using autograft bone. ODP Intervertebral Fusion Device With Bone Graft, Cervical 2 VariLift-C
46 00813210021341 CIC2-A001 VariLift-C Instrument Case LXH Orthopedic Manual Surgical Instrument 1 VariLift-C
47 00813210022393 800-0306 Implant Sizer - 6mm LXH Orthopedic Manual Surgical Instrument 1 primaLOK-SP
48 00813210020696 CIE3-A128 Expander, 28mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
49 00813210020689 CIE3-A124 Expander, 24mm MAX Intervertebral Fusion Device With Bone Graft, Lumbar 2 VariLift-LX
50 00813210020672 CIE3-A026 MI Graft Impactor LXH Orthopedic Manual Surgical Instrument 1 VariLift-LX
Other products with the same Product Code "ODP"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 B047CTRC1400 CTRC1400 SPINENET ACC ® -Transportation Case SPINENET ACC ® SPINENET, LLC
2 B047CTL1214100 CTL121410 Trial 12mmx14mmx10mm SPINENET ACC® SPINENET, LLC
3 B047CTL1214090 CTL121409 Trial 12mmx14mmx9mm SPINENET ACC® SPINENET, LLC
4 B047CTL1214080 CTL121408 Trial 12mmx14mmx8mm SPINENET ACC® SPINENET, LLC
5 B047CTL1214070 CTL121407 Trial 12mmx14mmx7mm SPINENET ACC® SPINENET, LLC
6 B047CTL1214060 CTL121406 Trial 12mmx14mmx6mm SPINENET ACC® SPINENET, LLC
7 B047CTL1214050 CTL121405 Trial 12mmx14mmx5mm SPINENET ACC® SPINENET, LLC
8 B047CTL1012100 CTL101210 Trial 10mmx12mmx10mm SPINENET ACC® SPINENET, LLC
9 B047CTL1012090 CTL101209 Trial 10mmx12mmx9mm SPINENET ACC® SPINENET, LLC
10 B047CTL1012080 CTL101208 Trial 10mmx12mmx8mm SPINENET ACC® SPINENET, LLC
11 B047CTL1012070 CTL101207 Trial 10mmx12mmx7mm SPINENET ACC® SPINENET, LLC
12 B047CTL1012060 CTL101206 Trial 10mmx12mmx6mm SPINENET ACC® SPINENET, LLC
13 B047CTL1012050 CTL101205 Trial 10mmx12mmx5mm SPINENET ACC® SPINENET, LLC
14 B047CL1214100 CL121410 12mmx14mmx10mm SPINENET ACC® SPINENET, LLC
15 B047CL1214090 CL121409 12mmx14mmx9mm SPINENET ACC® SPINENET, LLC
16 B047CL1214080 CL121408 12mmx14mmx8mm SPINENET ACC® SPINENET, LLC
17 B047CL1214070 CL121407 12mmx14mmx7mm SPINENET ACC® SPINENET, LLC
18 B047CL1214060 CL121406 12mmx14mmx6mm SPINENET ACC® SPINENET, LLC
19 B047CL1214050 CL121405 12mmx14mmx5mm SPINENET ACC® SPINENET, LLC
20 B047CL1012100 CL101210 10mmx12mmx10mm SPINENET ACC® SPINENET, LLC
21 B047CL1012090 CL101209 10mmx12mmx9mm SPINENET ACC® SPINENET, LLC
22 B047CL1012080 CL101208 10mmx12mmx8mm SPINENET ACC® SPINENET, LLC
23 B047CL1012070 CL101207 10mmx12mmx7mm SPINENET ACC® SPINENET, LLC
24 B047CL1012060 CL101206 10mmx12mmx6mm SPINENET ACC® SPINENET, LLC
25 B047CL1012050 CL101205 10mmx12mmx5mm SPINENET ACC ® SPINENET, LLC
26 B047CINS1100 CINS1100 SpineNet ACC® Inserter Assembly-Instrument SPINENET ACC ® SPINENET, LLC
27 B047CGRP1300 CGRP1300 SPINENET ACC ® Graft Pusher-Instrument SPINENET ACC ® SPINENET, LLC
28 B047CGRB1200 CGRB1200 SPINENET ACC ® Graft Block-Instrument SPINENET ACC ® SPINENET, LLC
29 B030SPC1620AN120 SPC-1620-AN12 16mm x 20mm, Anatomic, 12mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
30 B030SPC1620AN110 SPC-1620-AN11 16mm x 20mm, Anatomic, 11mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
31 B030SPC1620AN100 SPC-1620-AN10 16mm x 20mm, Anatomic, 10mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
32 B030SPC1620AN090 SPC-1620-AN09 16mm x 20mm, Anatomic, 9mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
33 B030SPC1620AN080 SPC-1620-AN08 16mm x 20mm, Anatomic, 8mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
34 B030SPC1620AN070 SPC-1620-AN07 16mm x 20mm, Anatomic, 7mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
35 B030SPC1620AN060 SPC-1620-AN06 16mm x 20mm, Anatomic, 6mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
36 B030SPC1620AN050 SPC-1620-AN05 16mm x 20mm, Anatomic, 5mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
37 B030SPC162012120 SPC-1620-1212 16mm x 20mm, 12° Lordotic, 12mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
38 B030SPC162012110 SPC-1620-1211 16mm x 20mm, 12° Lordotic, 11mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
39 B030SPC162012100 SPC-1620-1210 16mm x 20mm, 12° Lordotic, 10mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
40 B030SPC162012090 SPC-1620-1209 16mm x 20mm, 12° Lordotic, 9mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
41 B030SPC162012080 SPC-1620-1208 16mm x 20mm, 12° Lordotic, 8mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
42 B030SPC162012070 SPC-1620-1207 16mm x 20mm, 12° Lordotic, 7mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
43 B030SPC162012060 SPC-1620-1206 16mm x 20mm, 12° Lordotic, 6mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
44 B030SPC162012050 SPC-1620-1205 16mm x 20mm, 12° Lordotic, 5mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
45 B030SPC162007120 SPC-1620-0712 SPC-1620-0712 16mm x 20mm, 7° Lordotic, 12mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
46 B030SPC162007110 SPC-1620-0711 16mm x 20mm, 7° Lordotic, 11mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
47 B030SPC162007100 SPC-1620-0710 16mm x 20mm, 7° Lordotic, 10mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
48 B030SPC162007090 SPC-1620-0709 16mm x 20mm, 7° Lordotic, 9mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
49 B030SPC162007080 SPC-1620-0708 16mm x 20mm, 7° Lordotic, 8mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC
50 B030SPC162007070 SPC-1620-0707 16mm x 20mm, 7° Lordotic, 7mm SPIRA™-C Open Matrix Cervical Interbody CAMBER SPINE TECHNOLOGIES, LLC