Handheld, battery powered, biomicroscope that projects light into a patient’s e
Handheld, battery powered, biomicroscope that projects light into a patient’s eye. It is intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosisof diseases or trauma which affect the structural properties of the anterior eye segment.
AC powered biomicroscope that projects light into a patient's eye. The device
AC powered biomicroscope that projects light into a patient's eye. The device is intended for use in examining the anterior segment of the eye, from the corneal epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma, which affect the structural properties of the anterior segment of the eye.
Handheld, battery-powered, non-contact tonometer intended to measure the intraoc
Handheld, battery-powered, non-contact tonometer intended to measure the intraocular pressure of the eye. An air puff is used to momentarily flatten a patient's cornea during the measurement.
Handheld, battery-powered, contact tonometer. Indications for use include meas
Handheld, battery-powered, contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected.
Handheld, battery-powered, ultrasound device intended to measure the thicknes
Handheld, battery-powered, ultrasound device intended to measure the thickness of the cornea. The device tip is touched to a patient's eye during the measurement.
Handheld, battery-powered contact tonometer. Indications for use include measur
Handheld, battery-powered contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected.
AC-powered, non-contact tonometer intended to measure the intraocular pressure o
AC-powered, non-contact tonometer intended to measure the intraocular pressure of the eye and the biomechanical response of the cornea for the purpose of aiding in the diagnosis and monitoring of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement.
AC -powered non-contact tonometer intended to measure the intraocular pressure o
AC -powered non-contact tonometer intended to measure the intraocular pressure of the eye, taking into consideration the biomechanical response of the cornea. An air puff is used to momentarily flatten a patient's cornea during the measurement.
AC powered biomicroscope that projects light into a patient's eye. The device
AC powered biomicroscope that projects light into a patient's eye. The device is intended for use in examining the anterior segment of the eye, from the corneal epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma, which affect the structural properties of the anterior segment of the eye.
AC powered contact tonometer intended for the measurement of intraocular pressu
AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected.
AC powered contact tonometer intended for the measurement of intraocular pressu
AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected.
AC powered contact tonometer intended for the measurement of intraocular pressu
AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected.
Ten (10) replacement tip and membrane assemblies that attach to the Model 30 Pne
Ten (10) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement.
HKX
Tonometer, Ac-Powered
2
Model 30™ Tip and Membrane Assembly for Pneumatonometer
Three (3) replacement tip and membrane assemblies that attach to the Model 30 Pn
Three (3) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement.
HKX
Tonometer, Ac-Powered
2
Model 30™ Tip and Membrane Assembly for Pneumatonometer
One (1) replacement tip and membrane assembly that attaches to the Model 30 Pneu
One (1) replacement tip and membrane assembly that attaches to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement.
HKX
Tonometer, Ac-Powered
2
Model 30™ Tip and Membrane Assembly for Pneumatonometer
AC powered, non-contact tonometer indicated for measuring intraocular pressure
AC powered, non-contact tonometer indicated for measuring intraocular pressure to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement.
AC-powered, non-contact tonometer indicated for measuring intraocular pressure (
AC-powered, non-contact tonometer indicated for measuring intraocular pressure (IOP) to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement.
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination.
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination.
he AT 030 is an appliance that serves to measure intraocular pressure, according
he AT 030 is an appliance that serves to measure intraocular pressure, according to the Goldman method. Assessment of IOP may contribute to the diagnosis, and aid in the management of glaucoma.
The separation prisms is an accessory to the tonometer which is device intended
The separation prisms is an accessory to the tonometer which is device intended to estimate intraocular pressure by applying a force on the globe of the eye.
IBEX Tonometer is used for determining intraocular tension by measuring the pres
IBEX Tonometer is used for determining intraocular tension by measuring the pressure required to flatten a small area of the cornea.
The CATS-D Tonometer prism is intended to be used with Goldmann type tonometers
The CATS-D Tonometer prism is intended to be used with Goldmann type tonometers for the measurements of intraocular pressure of the human eye.
The CATS Tonometer Prism (CATS) is a modified Goldmann applanation tonometer (GA
The CATS Tonometer Prism (CATS) is a modified Goldmann applanation tonometer (GAT) prism that is optimized to work with the GAT's operating system to reduce errors in the measurement due to patient anatomical variation. This is used to measure intraocular pressure by applying a known force on the globe of the eye and measuring intraocular tension by applanation. Tonometer prisms are assembled onto a GAT as a patient contacting component that is then utilized by the GAT to assess intraocular pressure.
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination.
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination.
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination.
Handheld, battery-powered contact tonometer. Indications for use include measur
Handheld, battery-powered contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected.
Handheld, battery-powered, contact tonometer. Indications for use include meas
Handheld, battery-powered, contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected.
Schiotz tonometer with inclined scale, manufactured and certified by Gulden Opht
Schiotz tonometer with inclined scale, manufactured and certified by Gulden Ophthalmic, supplied with case, tables, zero test block and 5.5, 7.5, 10 and 15 gram weights
Schiotz tonometer weight - 5.5 gram, must send entire unit in for service when o
Schiotz tonometer weight - 5.5 gram, must send entire unit in for service when ordering this replacement part, service charge included in price listed
Allen-Schiotz tonometer with Plunger Retractor and inclined scale, manufactured
Allen-Schiotz tonometer with Plunger Retractor and inclined scale, manufactured and certified by Gulden Ophthalmics, supplied with case, tables, zero test block and 5.5, 7.5, 10 and 15 gram weights
Manual tonometer used to gauge internal pressure within the eye. An allen wrench
Manual tonometer used to gauge internal pressure within the eye. An allen wrench can be used to adjust weight settings.
Manual Tonometer is used to gauge the internal pressure of the eye using weights
Manual Tonometer is used to gauge the internal pressure of the eye using weights and a tonometer tip.