Other products from "REICHERT, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00812559010498 15090 Handheld, battery powered, biomicroscope that projects light into a patient’s e Handheld, battery powered, biomicroscope that projects light into a patient’s eye. It is intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosisof diseases or trauma which affect the structural properties of the anterior eye segment. HJO Biomicroscope, Slit-Lamp, Ac-Powered 2 PSL Portable Slit Lamp
2 00812559011297 15140 AC powered biomicroscope that projects light into a patient's eye. The device AC powered biomicroscope that projects light into a patient's eye. The device is intended for use in examining the anterior segment of the eye, from the corneal epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma, which affect the structural properties of the anterior segment of the eye. HJO Biomicroscope, Slit-Lamp, Ac-Powered 2 Xcel® 455 Slit Lamp
3 00812559010429 13850 Handheld, battery-powered, non-contact tonometer intended to measure the intraoc Handheld, battery-powered, non-contact tonometer intended to measure the intraocular pressure of the eye. An air puff is used to momentarily flatten a patient's cornea during the measurement. HKX Tonometer, Ac-Powered 2 PT100 Portable Non-Contact Tonometer
4 00812559010092 230635 Handheld, battery-powered, contact tonometer. Indications for use include meas Handheld, battery-powered, contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected. HKY Tonometer, Manual 2 Tono-Pen® XL
5 00812559011228 16040 Handheld, battery-powered, ultrasound device intended to measure the thicknes Handheld, battery-powered, ultrasound device intended to measure the thickness of the cornea. The device tip is touched to a patient's eye during the measurement. IYO System, Imaging, Pulsed Echo, Ultrasonic 2 iPac® Pachymeter
6 00812559010221 12598 Non-active, contact applanation tonometer intended to measure intraocular pressu Non-active, contact applanation tonometer intended to measure intraocular pressure of the eye. HKY Tonometer, Manual 2 CT210 Contact Tonometer
7 00812559010108 230650 Handheld, battery-powered contact tonometer. Indications for use include measur Handheld, battery-powered contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected. HKY Tonometer, Manual 2 Tono-Pen AVIA®
8 00812559011976 16170 AC-powered, non-contact tonometer intended to measure the intraocular pressure o AC-powered, non-contact tonometer intended to measure the intraocular pressure of the eye and the biomechanical response of the cornea for the purpose of aiding in the diagnosis and monitoring of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement. HKX Tonometer, Ac-Powered 2 Ocular Response Analyzer® G3
9 00812559011020 16060 AC -powered non-contact tonometer intended to measure the intraocular pressure o AC -powered non-contact tonometer intended to measure the intraocular pressure of the eye, taking into consideration the biomechanical response of the cornea. An air puff is used to momentarily flatten a patient's cornea during the measurement. HKX Tonometer, Ac-Powered 2 Reichert® 7CR Auto Tonometer
10 00812559010504 15120 AC powered biomicroscope that projects light into a patient's eye. The device AC powered biomicroscope that projects light into a patient's eye. The device is intended for use in examining the anterior segment of the eye, from the corneal epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma, which affect the structural properties of the anterior segment of the eye. HJO Biomicroscope, Slit-Lamp, Ac-Powered 2 Xcel® 255 Slit Lamp
11 08056098470463 12591 Non-active contact, applanation tonometer intended to measure intraocular pressu Non-active contact, applanation tonometer intended to measure intraocular pressure of the eye. HKY Tonometer, Manual 2 CT100 Contact Tonometer
12 00812559010979 16032 AC powered contact tonometer intended for the measurement of intraocular pressu AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected. HKX Tonometer, Ac-Powered 2 Model 30 Pneumatonometer
13 00812559010962 16031 AC powered contact tonometer intended for the measurement of intraocular pressu AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected. HKX Tonometer, Ac-Powered 2 Model 30 Pneumatonometer
14 00812559010955 16030 AC powered contact tonometer intended for the measurement of intraocular pressu AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected. HKX Tonometer, Ac-Powered 2 Model 30 Pneumatonometer
15 00812559012188 230678 Ten (10) replacement tip and membrane assemblies that attach to the Model 30 Pne Ten (10) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement. HKX Tonometer, Ac-Powered 2 Model 30™ Tip and Membrane Assembly for Pneumatonometer
16 00812559012171 230677 Three (3) replacement tip and membrane assemblies that attach to the Model 30 Pn Three (3) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement. HKX Tonometer, Ac-Powered 2 Model 30™ Tip and Membrane Assembly for Pneumatonometer
17 00812559012164 230676 One (1) replacement tip and membrane assembly that attaches to the Model 30 Pneu One (1) replacement tip and membrane assembly that attaches to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement. HKX Tonometer, Ac-Powered 2 Model 30™ Tip and Membrane Assembly for Pneumatonometer
18 00812559010177 16050 AC powered, non-contact tonometer indicated for measuring intraocular pressure AC powered, non-contact tonometer indicated for measuring intraocular pressure to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement. HKX Tonometer, Ac-Powered 2 Reichert® 7 Auto Tonometer
19 00812559012195 16080 AC-powered, non-contact tonometer indicated for measuring intraocular pressure ( AC-powered, non-contact tonometer indicated for measuring intraocular pressure (IOP) to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement. HKX Tonometer, Ac-Powered 2 VISUPLAN 500
20 00812559012096 230653 Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination. HKY Tonometer, Manual 2 Ocu-Film +
21 00812559012089 230652 Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination. HKY Tonometer, Manual 2 Ocu-Film +
Other products with the same Product Code "HKY"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 04049471090260 AT 030 he AT 030 is an appliance that serves to measure intraocular pressure, according he AT 030 is an appliance that serves to measure intraocular pressure, according to the Goldman method. Assessment of IOP may contribute to the diagnosis, and aid in the management of glaucoma. AT 030 CARL ZEISS MEDITEC AG
2 04045396131118 5114 5114 The eye tonometer used to measuring the intra-ocular pressure. schiötz C tonometer, inclined scale, silver, with 4 weights RUDOLF RIESTER GMBH
3 04045396131101 5113 5113 The eye tonometer used to measuring the intra-ocular pressure. schiötz C tonometer, inclined scale, gold RUDOLF RIESTER GMBH
4 04045396007109 5112 5112 The eye tonometer used to measuring the intra-ocular pressure. schiötz C tonometer, inclined scale, silver RUDOLF RIESTER GMBH
5 04045396007093 5111 5111 The eye tonometer used to measuring the intra-ocular pressure. schiötz B tonometer, inclined scale, silver RUDOLF RIESTER GMBH
6 04045396007086 5110 5110 The eye tonometer used to measuring the intra-ocular pressure. schiötz A tonometer, straight scale, silver RUDOLF RIESTER GMBH
7 03664188000107 Tonometer separation prisms L900 -box of 100 The separation prisms is an accessory to the tonometer which is device intended The separation prisms is an accessory to the tonometer which is device intended to estimate intraocular pressure by applying a force on the globe of the eye. Luneau LUNEAU TECHNOLOGY OPERATIONS
8 00897826002116 AX11286 AX11286 Bulk, non-sleeved AccuTip Cover ACCUTOME, INC.
9 00897826002109 AX11526 AX11526 Sleeved AccuTip Cover ACCUTOME, INC.
10 00897826002093 AX11932 AX11932 Individually wrapped AccuTip Cover ACCUTOME, INC.
11 00897826002086 AX9950 AX9950 Individually wrapped AccuTip Cover ACCUTOME, INC.
12 00897826002000 24-3000 24-3000 Accupen ACCUTOME, INC.
13 00869228000441 AT IBEX Tonometer is used for determining intraocular tension by measuring the pres IBEX Tonometer is used for determining intraocular tension by measuring the pressure required to flatten a small area of the cornea. Applanation Tonometer TREVI TECHNOLOGY, INC.
14 00867009000215 Prism B Disposable single use prism for FMAT1 Device FMAT1 Prism B FALCK MEDICAL INC
15 00867009000208 FMAT1 Indications for Use: Intraocular Pressure, Ocular Pulse Amplitude, Ophthalmodyna Indications for Use: Intraocular Pressure, Ocular Pulse Amplitude, Ophthalmodynamometry and Tonography Measurement Falck Medical Multi-Function Applanation Tonometer FALCK MEDICAL INC
16 00860412001541 CATS-D CATS-D The CATS-D Tonometer prism is intended to be used with Goldmann type tonometers The CATS-D Tonometer prism is intended to be used with Goldmann type tonometers for the measurements of intraocular pressure of the human eye. CATS ZIEN MEDICAL TECHNOLOGIES, INC.
17 00860412001510 CATS-R The CATS Tonometer Prism (CATS) is a modified Goldmann applanation tonometer (GA The CATS Tonometer Prism (CATS) is a modified Goldmann applanation tonometer (GAT) prism that is optimized to work with the GAT's operating system to reduce errors in the measurement due to patient anatomical variation. This is used to measure intraocular pressure by applying a known force on the globe of the eye and measuring intraocular tension by applanation. Tonometer prisms are assembled onto a GAT as a patient contacting component that is then utilized by the GAT to assess intraocular pressure. CATS Tonometer ZIEN MEDICAL TECHNOLOGIES, INC.
18 00841668112168 K 9-8500 K 9-8500 SCHIOTZ TONOMETER KATENA PRODUCTS, INC.
19 00812559012096 230653 Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination. Ocu-Film + REICHERT, INC.
20 00812559012089 230652 Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination. Ocu-Film + REICHERT, INC.
21 00812559010221 12598 Non-active, contact applanation tonometer intended to measure intraocular pressu Non-active, contact applanation tonometer intended to measure intraocular pressure of the eye. CT210 Contact Tonometer REICHERT, INC.
22 00812559010115 230651 Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect t Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination. Ocu-Film + REICHERT, INC.
23 00812559010108 230650 Handheld, battery-powered contact tonometer. Indications for use include measur Handheld, battery-powered contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected. Tono-Pen AVIA® REICHERT, INC.
24 00812559010092 230635 Handheld, battery-powered, contact tonometer. Indications for use include meas Handheld, battery-powered, contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected. Tono-Pen® XL REICHERT, INC.
25 00630238101721 OGBT-30-50 Griffin Barraquer 30-50mm Hg Tonometer OCULAR INSTRUMENTS, INC.
26 00630238099790 OKBT-20-30 Kasaby Barraquer 20-30mm Hg Tonometer OCULAR INSTRUMENTS, INC.
27 00630238067508 OBBT Barron Barraquer 65-90mm Hg Tonometer OCULAR INSTRUMENTS, INC.
28 00630238066426 OBVT Varley Barrquer 90mm Hg Tonometer OCULAR INSTRUMENTS, INC.
29 00630238061438 OBT-65-90 Barraquer 65-90mm Hg Tonometer OCULAR INSTRUMENTS, INC.
30 00630238053471 OBT-O Barraquer O-Ring Tonometer OCULAR INSTRUMENTS, INC.
31 00630238048019 OBT-65 Barraquer 65mm Hg Tonometer OCULAR INSTRUMENTS, INC.
32 00630238009058 OBT-TC-15-21 Terry Scale Barraquer 15-21mm Hg Tonometer OCULAR INSTRUMENTS, INC.
33 00630238009041 OBT-TC-10-15 Terry Scale Barraquer 10-15mm Hg Tonometer OCULAR INSTRUMENTS, INC.
34 00190660156084 5754E 5754E Schiotz tonometer with inclined scale, manufactured and certified by Gulden Opht Schiotz tonometer with inclined scale, manufactured and certified by Gulden Ophthalmic, supplied with case, tables, zero test block and 5.5, 7.5, 10 and 15 gram weights Ambler Surgical AMBLER SURGICAL CORP.
35 00190660156077 5759E 5759E Schiotz tonometer weight - 7.5 gram Ambler Surgical AMBLER SURGICAL CORP.
36 00190660156060 5758E 5758E Schiotz tonometer weight - 5.5 gram, must send entire unit in for service when o Schiotz tonometer weight - 5.5 gram, must send entire unit in for service when ordering this replacement part, service charge included in price listed Ambler Surgical AMBLER SURGICAL CORP.
37 00190660156053 5761E 5761E Schiotz tonometer weight - 15 gram Ambler Surgical AMBLER SURGICAL CORP.
38 00190660156046 5760E 5760E Schiotz tonometer weight - 10 gram Ambler Surgical AMBLER SURGICAL CORP.
39 00190660156039 5762E 5762E Schiotz tonometer replacement transportation case Ambler Surgical AMBLER SURGICAL CORP.
40 00190660156022 5757E 5757E Allen-Schiotz tonometer with Plunger Retractor and inclined scale, manufactured Allen-Schiotz tonometer with Plunger Retractor and inclined scale, manufactured and certified by Gulden Ophthalmics, supplied with case, tables, zero test block and 5.5, 7.5, 10 and 15 gram weights Ambler Surgical AMBLER SURGICAL CORP.
41 B091131100 13110 13110 Manual tonometer used to gauge internal pressure within the eye. An allen wrench Manual tonometer used to gauge internal pressure within the eye. An allen wrench can be used to adjust weight settings. Schioetz Tonometer - Allen Wrench Modification GULDEN OPHTHALMICS INC.
42 B091131070 13107 13107 Manual Tonometer is used to gauge the internal pressure of the eye using weights Manual Tonometer is used to gauge the internal pressure of the eye using weights and a tonometer tip. Schioetz Tonometer GULDEN OPHTHALMICS INC.
43 16430033850623 TP022 Sales package 50pcs Probes for HOME ICARE FINLAND OY
44 10381780159544 18132 18-132 SCHIOTZ TONOMETER, Original Model Integra® Miltex® INTEGRA LIFESCIENCES PRODUCTION CORPORATION
45 08056098470517 TONOMETER A900 102002200.S APPLANATION TONOMETER S4 OPTIK COSTRUZIONI STRUMENTI OFTALMICI C.S.O. SRL
46 08056098470463 12591 Non-active contact, applanation tonometer intended to measure intraocular pressu Non-active contact, applanation tonometer intended to measure intraocular pressure of the eye. CT100 Contact Tonometer REICHERT, INC.
47 08056098470425 TONOMETER F900 102002100.S APPLANATION TONOMETER S4 OPTIK COSTRUZIONI STRUMENTI OFTALMICI C.S.O. SRL
48 07640167751174 Sensorcaps 311.701.201 SensorCaps-240 PASCAL SMT SWISS MICROTECHNOLOGY AG
49 07640132986907 Modell BQ 1420157 Special color Tonometer AT 900 HAAG-STREIT AG
50 07640132986082 n/a 1001310 Tonometer AT 870 HAAG-STREIT AG