Other products from "ACCURAY INCORPORATED"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 M65810604640 1060464 NA Software, TomoApps, Version 5.1.2Operating Software for TomoTherapy systems (inc Software, TomoApps, Version 5.1.2Operating Software for TomoTherapy systems (including TomoH®, TomoHD®, TomoHDA) and Onrad Treatment System™ IYE,MUJ Accelerator, Linear, Medical,System, Planning, Radiation Therapy Treatment 2 NA
2 M65810602530 1060253 N/A Radixact Delivery System Software (Version 1.1) IYE Accelerator, Linear, Medical 2 Radixact™ Treatment Delivery System
3 M65810476410 1047641-000 NA CyberKnife® M6™ Series (including configurations: M6 Neuro, M6 FI, M6 FIM, & M6 CyberKnife® M6™ Series (including configurations: M6 Neuro, M6 FI, M6 FIM, & M6 FM)The CyberKnife M6 Systems are computer-controlled medical systems for planning and performing minimally invasive stereotactic radiosurgery and precision radiotherapy. They use a 6 MV linear accelerator mounted on a manipulator (robot) and a target locating subsystem to accurately deliver high-energy radiation (1000 MU/minute dose rate) to the treatment target. The target locating subsystem provides X-rays of the treatment area that lets the user know the position of the target.The CyberKnife M6 Systems use skull tracking, fiducial tracking (tracking of implanted radiographic markers), skeletal structure tracking, lung tumor tracking, Lung Optimized Treatment, and Synchrony Respiratory Tracking for dynamic positioning and pointing of the linear accelerator. The fixed, variable aperture and multileaf collimators are available as various beam-limiting secondary collimators. IYE Accelerator, Linear, Medical 2 CyberKnife® M6™ Systems
4 M65810598110 1059811 NA Software, Version 1.1.1, Accuray Precision Treatment Planning SystemThe Accuray Software, Version 1.1.1, Accuray Precision Treatment Planning SystemThe Accuray Precision Treatment Planning System is a radiation therapy planning system used for creation and assessment of treatment plans for delivery by radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery treatment systems. IYE,MUJ Accelerator, Linear, Medical,System,Planning,Radiation Therapy Treatment 2 Accuray Precision® Treatment Planning System
5 M65810577270 1057727 NA Software, Version 1.0.0.4, Treatment Delivery Console, Radixact(Operating Softwa Software, Version 1.0.0.4, Treatment Delivery Console, Radixact(Operating Software for Radixact Treatment Delivery System) IYE Accelerator, Linear, Medical 2 Radixact®, Treatment Delivery Console (TDC)
6 M65810573750 1057375 NA Software, Delivery Analysis, Version 1.2 IYE,MUJ Accelerator, Linear, Medical,System,Planning,Radiation Therapy Treatment 2 Delivery Analysis TM
7 M65810565930 1056593 NA Software, Version 1.0.0.3, Treatment Delivery Console (TDC), Radixact(Operating Software, Version 1.0.0.3, Treatment Delivery Console (TDC), Radixact(Operating Software for Radixact® Treatment Delivery System) IYE Accelerator, Linear, Medical 2 Radixact®, Treatment Delivery Console (TDC)
8 M65810550960 1055096 NA Software, Version 1.0.0.1, Accuray Precision Treatment Planning System, The Accu Software, Version 1.0.0.1, Accuray Precision Treatment Planning System, The Accuray Precision Treatment Planning System is a radiation therapy planning system used for creation and assessment of treatment plans for delivery by radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery treatment systems. MUJ System,Planning,Radiation Therapy Treatment 2 Accuray Precision® Treatment Planning System
9 M65810525910 1052591 NA Software, Delivery Analysis, Version 1.1 MUJ,IYE System,Planning,Radiation Therapy Treatment,Accelerator, Linear, Medical 2 Delivery Analysis TM
10 M65810502420 1050242 NA Software, Version 1.0, Precision Treatment Planning SystemThe Accuray Precision Software, Version 1.0, Precision Treatment Planning SystemThe Accuray Precision Treatment Planning System is indicated for creation and assessment of external photon beam irradiation treatment plans for radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery for lesions, tumors and conditions anywhere in the body when radiation treatment is indicated. A treatment plan provides an estimate of the dose distribution and the parameters utilized by the radiation delivery system. Plans must be reviewed and approved by qualified medical practitioners prior to delivery. MUJ System,Planning,Radiation Therapy Treatment 2 Accuray Precision® Treatment Planning System
11 M65810502410 1050241 NA Software, Version 1.0.0.1, Treatment Delivery Console (TDC), Radixact(Operating Software, Version 1.0.0.1, Treatment Delivery Console (TDC), Radixact(Operating Software for Radixact® Treatment Delivery System) IYE Accelerator, Linear, Medical 2 Radixact®, Treatment Delivery Console (TDC)
12 M65810642700 1064270 NA Software, Version 2.0, Accuray Precision Treatment Planning SystemThe Accuray Pr Software, Version 2.0, Accuray Precision Treatment Planning SystemThe Accuray Precision Treatment Planning System is a radiation therapy planning system used for creation and assessment of treatment plans for delivery by radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery treatment systems. MUJ System, Planning, Radiation Therapy Treatment 2 Accuray Precision® Treatment Planning System
13 M65810624240 1062424 NA Software, TomoApps, Version 5.1.3Operating Software for TomoTherapy systems (inc Software, TomoApps, Version 5.1.3Operating Software for TomoTherapy systems (including TomoH, TomoHD, TomoHDA) and Onrad Treatment System. IYE,MUJ Accelerator, Linear, Medical,System, Planning, Radiation Therapy Treatment 2 NA
14 M65810617990 1061799 NA Software, Accuray Precision Treatment Planning System, (Version 1.1.1.1)The Accu Software, Accuray Precision Treatment Planning System, (Version 1.1.1.1)The Accuray Precision Treatment Planning System is a radiation therapy planning system used for creation and assessment of treatment plans for delivery by radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery treatment systems. MUJ,IYE System,Planning,Radiation Therapy Treatment,Accelerator, Linear, Medical 2 Accuray Precision® Treatment Planning System
15 M6580330000 033000-000 NA The CyberKnife VSI System is a computer controlled medical systems for planning The CyberKnife VSI System is a computer controlled medical systems for planning and performing minimally invasive stereotactic radiosurgery and precision radiotherapy using a treatment radiation generator, linear accelerator, manipulator (robot), and a target locating subsystem to accurately deliver radiation to the treatment target. The target locating system provides X-rays of the treatment area taken by a diagnostic X-ray system that lets the user know the position of the target. The CyberKnife VSI Systems use skull tracking, fiducial tracking, Xsight® Spine Tracking, Xsight® Lung Tracking, and Synchrony® Respiratory Tracking for dynamic positioning and pointing of the linear accelerator. The system uses a 6 MV linear accelerator to provide a dose rate up to 1000 MU/minute. IYE Accelerator, Linear, Medical 2 CyberKnife VSI® System
16 M65810182840 1018284-000 NA TomoTherapy® Treatment System (H Series) IYE,MUJ Accelerator, Linear, Medical,System,Planning,Radiation Therapy Treatment 2 TomoH® Treatment Delivery System
17 M65810600000 1060000 NA The Radixact Treatment Delivery System is a radiation therapy delivery system th The Radixact Treatment Delivery System is a radiation therapy delivery system that provides Image Guided Radiation Therapy (IGRT) using integral megavoltage CTimaging capabilities and delivers helical (rotational) and fixed-angle (non-rotational) radiation therapy to tumors and other targeted tissues.The Radixact Treatment Delivery System is a prescription device that delivers radiation in accordance with a physician approved plan. The Radixact Treatment Delivery System does not diagnose disease, recommend treatment regimens or quantify treatment effectiveness. It is not intended for diagnostic use. IYE Accelerator, Linear, Medical 2 Radixact® Treatment Delivery System
18 M6581055810 1055810 NA Software, Version 11.0, CyberKnife(Operating Software group for CyberKnife Treat Software, Version 11.0, CyberKnife(Operating Software group for CyberKnife Treatment Delivery System) IYE Accelerator, Linear, Medical 2 CyberKnife® Treatment Delivery System
19 M65810492110 1049211 NA The Onrad™ Treatment System is a radiation therapy system that integrates planni The Onrad™ Treatment System is a radiation therapy system that integrates planning, dosecalculation, megavoltage CT imaging for IGRT functionality, and fixed beam (non-rotational)radiation therapy treatment capabilities into a single comprehensive system.The Onrad™ Treatment System is a prescription device. It delivers radiation in accordancewith a physician approved plan. The device does not diagnose disease, recommend treatmentregimens, or quantify treatment effectiveness. The megavoltage CT imaging functionality isnot intended for diagnostic use. MUJ System, Planning, Radiation Therapy Treatment 2 Onrad Treatment System
20 M65806600000 0660000 NA The CyberKnife® Treatment Delivery System (CKTDS) is a computer-controlled radia The CyberKnife® Treatment Delivery System (CKTDS) is a computer-controlled radiation treatment delivery system for performing minimally invasive stereotactic radiosurgery and precision radiotherapy. The CyberKnife Treatment Delivery System is intended to work with Accuray Precision® Treatment Planning System and iDMS™ Data Management System. IYE Accelerator, Linear, Medical 2 CyberKnife® Treatment Delivery System
21 M65810682840 1068284 NA The TomoTherapy Treatment Delivery System with iDMS is indicated for the deliver The TomoTherapy Treatment Delivery System with iDMS is indicated for the delivery of radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery to tumors or other targeted tissues anywhere in the body under the direction of a licensed medical practitioner. IYE Accelerator, Linear, Medical 2 TomoTherapy Treatment Delivery System with iDMS
22 M65810682860 1068286 NA The TomoTherapy Treatment Delivery System with iDMS is indicated for the deliver The TomoTherapy Treatment Delivery System with iDMS is indicated for the delivery of radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery to tumors or other targeted tissues anywhere in the body under the direction of a licensed medical practitioner. IYE Accelerator, Linear, Medical 2 TomoTherapy Treatment Delivery System with iDMS
23 M65810682830 1068283 NA The TomoTherapy Treatment Delivery System with iDMS is indicated for the deliver The TomoTherapy Treatment Delivery System with iDMS is indicated for the delivery of radiation therapy, stereotactic radiotherapy or stereotactic radiosurgery to tumors or other targeted tissues anywhere in the body under the direction of a licensed medical practitioner. IYE Accelerator, Linear, Medical 2 TomoTherapy Treatment Delivery System with iDMS
24 M65810620710 1062071 NA TomoTherapy Treatment Delivery System with iDMS, Version 1.1 IYE Accelerator, Linear, Medical 2 TomoTherapy Treatment Delivery System with iDMS
25 M65810643150 1064315 NA Software, Delivery Analysis, Version 1.2.2 IYE Accelerator, Linear, Medical 2 Delivery Analysis
26 M65810622130 1062213 NA Software, Delivery Analysis, Version 1.2.1 MUJ,IYE System, Planning, Radiation Therapy Treatment,Accelerator, Linear, Medical 2 Delivery Analysis
27 M6581043090 H-0000-0003 NA TomoTherapy Treatment System (Tomo HD™) IYE Accelerator, Linear, Medical 2 TomoTherapy Treatment System (Tomo HD™)
28 M65810466130 H-0000-0003 NA TomoTherapy Treatment System (re-new system) IYE Accelerator, Linear, Medical 2 reNEW™ Certified Pre-Owned System
29 M6580325000 032500-M-000 NA The CyberKnife VSI System is a computer controlled medical systems for planning The CyberKnife VSI System is a computer controlled medical systems for planning and performing minimally invasive stereotactic radiosurgery and precision radiotherapy using a treatment radiation generator, linear accelerator, manipulator (robot), and a target locating subsystem to accurately deliver radiation to the treatment target. The target locating system provides X-rays of the treatment area taken by a diagnostic X-ray system that lets the user know the position of the target. The CyberKnife VSI Systems use skull tracking, fiducial tracking, Xsight® Spine Tracking, Xsight® Lung Tracking, and Synchrony® Respiratory Tracking for dynamic positioning and pointing of the linear accelerator. The system uses a 6 MV linear accelerator to provide a dose rate up to 1000 MU/minute. IYE Accelerator, Linear, Medical 2 CyberKnife® VSI™ System
30 M65810615130 1061513 NA Software, Version 2.0, iDMS Data Management SystemThe iDMS Data Management Syste Software, Version 2.0, iDMS Data Management SystemThe iDMS Data Management System is indicated for the storage, retrieval, and processing of data utilized in the practice of radiotherapy, stereotactic radiotherapy and stereotactic radiosurgery. IYE Accelerator, Linear, Medical 2 iDMS Data Management System
31 M65810489680 1048968 N/A Software, TomoApps, Version 2.1.1, Build # 5.1.1(Operating Software for TomoTher Software, TomoApps, Version 2.1.1, Build # 5.1.1(Operating Software for TomoTherapy systems, including TomoH®, TomoHD®, TomoHDA™ and Onrad™) IYE,MUJ Accelerator, Linear, Medical,System,Planning,Radiation Therapy Treatment 2 TomoTherapy® Treatment Delivery System
32 M65810572080 1057208 NA Software, Version 1.1, iDMS™ Data Management SystemThe iDMS™ Data Management Sys Software, Version 1.1, iDMS™ Data Management SystemThe iDMS™ Data Management System is indicated for the storage, retrieval, and processing of data utilized in the practice of radiotherapy, stereotactic radiotherapy and stereotactic radiosurgery. IYE Accelerator, Linear, Medical 2 iDMS™ Data Management System
33 M65810554870 1055487 NA Software, Version 1.0.0.2, Treatment Delivery Console, RadixactVersion 1.0.0.2(O Software, Version 1.0.0.2, Treatment Delivery Console, RadixactVersion 1.0.0.2(Operating Software for Radixact Treatment Delivery System) IYE Accelerator, Linear, Medical 2 Radixact®, Treatment Delivery Console
34 M65810498890 1049889 NA Software, Version 1.0, iDMS™ Data Management SystemThe iDMS™ Data Management Sys Software, Version 1.0, iDMS™ Data Management SystemThe iDMS™ Data Management System is indicated for the storage, retrieval, and processing of data utilized in the practice of radiotherapy, stereotactic radiotherapy and stereotactic radiosurgery. IYE Accelerator, Linear, Medical 2 iDMS™ Data Management System
35 00811376030085 1061514 NA IDMS Data Management System (Version 3.0) MUJ,IYE System, Planning, Radiation Therapy Treatment,Accelerator, Linear, Medical 2 iDMS Data Management System
36 M65810624090 1062409 NA Software, iDMS™ Data Management System, (Version 1.1.1.1)The iDMS™ Data Manageme Software, iDMS™ Data Management System, (Version 1.1.1.1)The iDMS™ Data Management System is indicated for the storage, retrieval, and processing of data utilized in the practice of radiotherapy, stereotactic radiotherapy and stereotactic radiosurgery. IYE Accelerator, Linear, Medical 2 iDMS™ Data Management System
37 M65810182830 1018283-000 NA TomoTherapy Treatment System (H Series) IYE,MUJ Accelerator, Linear, Medical,System,Planning,Radiation Therapy Treatment 2 TomoHD® Treatment Delivery System
Other products with the same Product Code "IYE"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 B237MIB3 MIB-3 Varian Exact™ Couch Indexing Bar-50cm Overlay DIACOR, INC.
2 B237MIB10 MIB-1 Varian Exact™ Couch Indexing Bar-53cm Overlay DIACOR, INC.
3 B229MRT21 2 MarkRT MATH RESOLUTIONS, LLC
4 B229MC11 1 MillComp MATH RESOLUTIONS, LLC
5 B229DC051 5 Dosimetry Check MATH RESOLUTIONS, LLC
6 B229DC041 4 Dosimetry Check MATH RESOLUTIONS, LLC
7 B120ALIGNRT0 AlignRT AlignRT Vision RT VISION RT LIMITED
8 B01612300009Z0 12300009Z 12300009Z Radiation Therapy QA Device. For use with the 1230 3D SCANNER. WaterProof PROFILER SUN NUCLEAR CORP.
9 B01612300004Z0 12300004Z 12300004Z Accessory to the 1230 3D SCANNER. 3D SCANNER TPR Option SUN NUCLEAR CORP.
10 B01612300002Z0 12300002Z 12300002Z Accessory to the 1230 3D SCANNER. 3D Reservoir SUN NUCLEAR CORP.
11 B01612300000Z0 12300000Z 12300000Z Radiation therapy QA device. 3D SCANNER (BNC) SUN NUCLEAR CORP.
12 B01612300000TZ0 12300000TZ 12300000TZ Radiation therapy QA device. 3D SCANNER (TNC) SUN NUCLEAR CORP.
13 B0161220200Z0 1220200Z 1220200Z Accessory to Model 1220 ArcCHECK. ArcCHECK Trolley SUN NUCLEAR CORP.
14 B01612200000Z0 12200000Z 12200000Z Radiation therapy QA device. ArcCHECK SUN NUCLEAR CORP.
15 B01612200000MR0 12200000MR 12200000MR Radiation therapy QA device. ArcCHECK-MR SUN NUCLEAR CORP.
16 B016121700000 12170000 12170000 Radiation therapy QA device. DoseCHECK SUN NUCLEAR CORP.
17 B016121600000 12160000 12160000 Radiation therapy QA device. PlanIQ SUN NUCLEAR CORP.
18 B01612150000Z0 12150000Z 12150000Z Radiation therapy QA device. PerFRACTION SUN NUCLEAR CORP.
19 B016121400000 12140000 12140000 Radiation therapy QA device. EPIDose SUN NUCLEAR CORP.
20 B016121200000 12120000 12120000 Radiation therapy QA device. 3DVH SUN NUCLEAR CORP.
21 B01611790000Z0 11790000Z 11790000Z Radiation therapy QA device. SRS MapCHECK SUN NUCLEAR CORP.
22 B01611780000Z0 11780000Z 11780000Z Radiation therapy QA device. MapCHECK 3 SUN NUCLEAR CORP.
23 B0161177000VZ0 1177000VZ 1177000VZ Accessory to the 1177 MapCHECK2. Varian IMF (Isocentric Mounting Fixture) SUN NUCLEAR CORP.
24 B0161177000SZ0 1177000SZ 1177000SZ Accessory to the 1177 MapCHECK2. Siemens IMF (Isocentric Mounting Fixture) SUN NUCLEAR CORP.
25 B0161177000EZ0 1177000EZ 1177000EZ Accessory to the 1177 MapCHECK2. Elekta IMF (Isocentric Mounting Fixture) SUN NUCLEAR CORP.
26 B01611770000Z0 11770000Z 11770000Z Radiation therapy QA device. MapCHECK2 SUN NUCLEAR CORP.
27 B01611740000Z0 11740000Z 11740000Z Radiation therapy QA device. PROFILER 2 SUN NUCLEAR CORP.
28 B016117081Z0 117081Z 117081Z Accessory to the Model 1174 PROFILER 2. Electron Energy Verification Wedge SUN NUCLEAR CORP.
29 B01611370000Z0 11370000Z 11370000Z Radiation therapy QA device. IVD 2 SUN NUCLEAR CORP.
30 B01611360000Z0 11360000Z 11360000Z Radiation therapy QA device. rf-IVD 2 SUN NUCLEAR CORP.
31 B0161122AZ0 1122AZ 1122AZ Accessory to the 1177 MapCHECK2. Adaptor Plate for GMF SUN NUCLEAR CORP.
32 B01611180001Z0 11180001Z 11180001Z Radiation therapy QA device. EDGE Dosimetry Detector (TNC) SUN NUCLEAR CORP.
33 B01611180000Z0 11180000Z 11180000Z Radiation therapy QA device. EDGE Dosimetry Detector (BNC) SUN NUCLEAR CORP.
34 B01610140001Z0 10140001Z 10140001Z Radiation therapy QA device. PC Electrometer Reference Class Dual-Channel Electrometer (TNC) SUN NUCLEAR CORP.
35 B01610140000Z0 10140000Z 10140000Z Radiation therapy QA device. PC Electrometer Reference Class Dual-Channel Electrometer (BNC) SUN NUCLEAR CORP.
36 SNMR05000521200 SNMR-050-005-2120 SNMR-050-005-2120 0.50mm x 01.0cm VISICOIL MR Platinum loaded in an 21 gauge 20cm pre-waxed needle. VISICOIL MR RADIOMED CORP
37 SNMR0500050 SNMR-050-005-2120 SNMR-050-005-2120 0.50mm x 0.5cm VISICOIL MR Platinum loaded in an 21 gauge 20cm pre-waxed needle. VISICOIL MR RADIOMED CORP
38 SHZ03502022 SHZ-035-020-22 SHZ-035-020-22 0.35mm x 2.0cm VISICOIL MR Platinum loaded into a pre-waxed 22 gauge 38.5cm needle. VISICOIL MR RADIOMED CORP
39 SHZ03501022 SHZ-035-010-22 SHZ-035-010-22 0.35mm x 1.0cm VISICOIL MR Platinum loaded into a pre-waxed 22 gauge 38.5cm needle. VISICOIL MR RADIOMED CORP
40 SHZ03500522 SHZ-035-005-22 SHZ-035-005-22 0.35mm x 0.5cm VISICOIL MR Platinum loaded into a pre-waxed 22 gauge 38.5cm needle. VISICOIL MR RADIOMED CORP
41 20858086006294 P1008016005 Head Frame - Post Assembly Set VARIAN MEDICAL SYSTEMS, INC.
42 19120075320037 1.2 ImagingRing MEDPHOTON GMBH
43 19120075320013 1.1 ImagingRing MEDPHOTON GMBH
44 17350005280045 SP003 HY-005 Catalyst+ C-RAD POSITIONING AB
45 17350005280038 SP003 HY-004 Catalyst+ C-RAD POSITIONING AB
46 17350005180093 Wired (PW) SDOS101-46 The intended use of the device is• quality assurance of patient specific treatme The intended use of the device is• quality assurance of patient specific treatment delivery prior to the treatment in IMRT (including VMAT) and 4DRT (e.g. respiratory gating and tumour tracking).• quality assurance of the radiation delivery system. Delta4 Phantom+ SCANDIDOS AB
47 17350005180086 PW SDOS101-34 The intended use of the device is• quality assurance of patient specific treatme The intended use of the device is• quality assurance of patient specific treatment delivery prior to the treatment in IMRT (including VMAT) and 4DRT (e.g. respiratory gating and tumour tracking).• quality assurance of the radiation delivery system. Delta4 Phantom+ MR SCANDIDOS AB
48 17350005180079 Elekta SDOS105-02 The intended use of the device is• quality assurance of patient specific treatme The intended use of the device is• quality assurance of patient specific treatment delivery during and before external radiotherapy treatment, including IMRT, VMAT and 4DRT (respiratory gating and tumour tracking)• quality assurance of the radiation delivery system. Delta4 Discover SCANDIDOS AB
49 17350005180062 SDOS105-01 SDOS105-01 (Varian) The intended use of the device is• quality assurance of patient specific treatme The intended use of the device is• quality assurance of patient specific treatment delivery during and before external radiotherapy treatment, including IMRT, VMAT and 4DRT (respiratory gating and tumour tracking)• quality assurance of the radiation delivery system. Delta4 Discover SCANDIDOS AB
50 17350005180048 PMMA SDOS101-36 The intended use of the device is• quality assurance of patient specific treatme The intended use of the device is• quality assurance of patient specific treatment delivery prior to the treatment in IMRT (including VMAT) and 4DRT (e.g. respiratory gating and tumour tracking).• quality assurance of the radiation delivery system. Delta4 Phantom+ MR SCANDIDOS AB