Non- sterile flexible disposable drain bag with hose adapters for use on Dornier
Non- sterile flexible disposable drain bag with hose adapters for use on Dornier Genesis Urological Table
Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jac
Radial Emission Fiber, core 550µm, clad 578µm, fiber OD 1300µm, white Tefzel Jacket with length marking, SMA 905 connector, black protection cap, black bend protection, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jack
Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket with length marking, SMA 905 connector, black protection cap, black bend protection, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber - Radial Emission Fiber 600µm Vein
Radial Emission Fiber Vein, core 550µm, clad 578µm, fiber OD 1400µm, white Tefze
Radial Emission Fiber Vein, core 550µm, clad 578µm, fiber OD 1400µm, white Tefzel Jacket with length marking, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber - Radial Emission Fiber 600µm Stopper
Radial Emission Fiber with Stopper, core 550µm, clad 578µm, fiber OD 1400µm, whi
Radial Emission Fiber with Stopper, core 550µm, clad 578µm, fiber OD 1400µm, white Tefzel Jacket, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, stopper 466mm from distal end, distal conical tip with silica capillary dome 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber - Radial Emission Fiber 400µm Vein
Radial Emission Fiber Vein, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel
Radial Emission Fiber Vein, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket with length marking, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber - Radial Emission Fiber 400µm Stopper
Radial Emission Fiber with Stopper, core 400µm, clad 420µm, fiber OD 900µm, whit
Radial Emission Fiber with Stopper, core 400µm, clad 420µm, fiber OD 900µm, white Tefzel Jacket, SMA 905 connector, PVC protection cap, RFID extension sleeve red, black bend protection, stopper 466mm from distal end, distal conical tip with silica capillary dome 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Ja
Radial Emission Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jacket with length marking, standard SMA905 connector with knurl nut, PVC protection cap, extension sleeve red engraved, black bend protection, LUER adapter, distal conical tip with silica capillary dome, capillary OD 1000µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Corona 360 Fiber, core 550µm, clad 578µm, fiber OD 1400µm, white Vestodur Jacket
Corona 360 Fiber, core 550µm, clad 578µm, fiber OD 1400µm, white Vestodur Jacket with length marking, customized connector, white bend protection, distal conical tip with silica capillary dome, capillary OD 1800µm, NA 0.22, length 2,6m +/-0,2m, sterile EO, disposable, double packed
Laser Surgery Fiber, core 320µm, clad 385µm, fiber OD 415µm, polyimide coating,
Laser Surgery Fiber, core 320µm, clad 385µm, fiber OD 415µm, polyimide coating, standard SMA 905 connector with knurl nut, PVC protection cap, extension sleeve red engraved, black bend protection, Silicone tubing OD 2mm, distal flat tip, cleaved, 10cm freestanding fiber, NA 0.22, length 3m +/-0,2m, sterile EO, disposable, single packed,
Laser Surgery Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jack
Laser Surgery Fiber, core 400µm, clad 420µm, fiber OD 950µm, white Vestodur Jacket with length marking, standard SMA 905 connector with knurl nut, PEEK protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, NA 0.22, length 3m +/-0,2m, sterile EO, double packed
Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket,
Laser Surgery Fiber, core 600µm, clad 660µm, fiber OD 870µm, blue Tefzel Jacket, SMA 905 holmium connector with knurl nut, black protection cap, engraved extension sleeve red, black bend protection, distal flat tip, cleaved, 3mm stripped, NA 0.22, length 3m +/-0,2m, sterile EO, disposable, double packed
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, freestanding SMA 905, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop blue 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, freestanding SMA 905, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop green 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop yellow 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420
Fiber Probe for Magnetic Resonance Imaging, core 272µm, clad 300µm, fiber OD 420µm, transparent Nylon Jacket, SMA 905 connector, black protection cap, extension sleeve silver, black PVC protection tube OD 1,5mm over 3m+/-0,1m on the proximal side, fiber stop red 235mm +/-1mm from distal end, distal flat tip, cleaved, NA 0.22, length 10m +/-0,05m, sterile EO, disposable, double packed